Astronics Trig-Tek 850A Скачать руководство пользователя страница 1

Artisan Technology Group 

is your source for quality 

new and certified-used/pre-owned equipment

• 

FAST SHIPPING AND 

DELIVERY

• 

TENS OF THOUSANDS OF 

IN-STOCK ITEMS

•  EQUIPMENT DEMOS
• 

HUNDREDS OF 

MANUFACTURERS 

SUPPORTED

•  LEASING/MONTHLY

 

RENTALS

•  ITAR CERTIFIED

           

SECURE ASSET 

SOLUTIONS

SERVICE CENTER REPAIRS

Experienced engineers and technicians on staff 

at our full-service, in-house repair center

WE BUY USED EQUIPMENT

Sell your excess, underutilized, and idle used equipment 

We also offer credit for buy-backs and trade-ins

www.artisantg.com/WeBuyEquipment

                        

REMOTE INSPECTION

Remotely inspect equipment before purchasing with 

our interactive website at

 

www.instraview.com

LOOKING FOR MORE INFORMATION? 

Visit us on the web at

 

www.artisantg.com

    

for more 

information on price quotations, drivers, technical 

specifications, manuals, and documentation

Contact us:

 

 

(888) 88-SOURCE  |  [email protected]  |  www.artisantg.com

SM

View

Instra

Содержание Trig-Tek 850A

Страница 1: ...l service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE INSPECTION Remotely inspect equipment before purchasing with our interactive website at www instraview com LOOKING FOR MORE INFORMATION Visit us on the web at www artisantg com for more information on ...

Страница 2: ...ronics com atssales astronics com atshelpdesk astronics com http www astronicstestsystems com Copyright 2011 by Astronics Test Systems Inc Printed in the United States of America All rights reserved This book or parts thereof may not be reproduced in any form without written permission of the publisher Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Страница 3: ...cs Test Systems express written consent or misuse of any product or part The warranty also does not apply to fuses software non rechargeable batteries damage from battery leakage or problems arising from normal wear such as mechanical relay life or failure to follow instructions This warranty is in lieu of all other warranties expressed or implied including any implied warranty of merchantability ...

Страница 4: ... Systems TRADEMARKS AND SERVICE MARKS All trademarks and service marks used in this document are the property of their respective owners Racal Instruments Talon Instruments Trig Tek ActivATE Adapt A Switch N GEN and PAWS are trademarks of Astronics Test Systems in the United States DISCLAIMER Buyer acknowledges and agrees that it is responsible for the operation of the goods purchased and should e...

Страница 5: ...his will defeat the protective feature of the third conductor in the power cord Maintenance and calibration procedures sometimes call for operation of the unit with power applied and protective covers removed Read the procedures and heed warnings to avoid live circuit points Before operating this instrument 1 Ensure the proper fuse is in place for the power source to operate 2 Ensure all other dev...

Страница 6: ...ower 1 3 Chapter 2 2 1 Operation 2 1 Current Setting 2 1 Time Interval Switch Settings 2 1 Contact Connections and Switches 2 1 Fault 2 2 Chapter 3 3 1 Calibration 3 1 Timing Interval Adjustment 3 1 Contact Current Adjustment 3 2 Astronics Test Systems i Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Страница 7: ...850A B User Manual Publication No 980972 Rev B This page intentionally left blank ii Astronics Test Systems Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Страница 8: ... Contact Chatter Detector 1 1 Figure 1 2 Trig Tek 850B Contact Chatter Detector 1 1 Figure 2 1 Switch S1 Input Voltage Setting 2 2 Figure 3 1 Calibration Adjustments 3 1 Astronics Test Systems iii Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Страница 9: ... 2 23 2011 Document Control release B 5 17 2012 ECN00301 adding 850A configuration information Added ITAR statements B 8 29 2012 ECN01438 Administrative document change Remove ITAR statements iv Astronics Test Systems Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Страница 10: ...ltaneously for 0 1 to 11 milliamps The difference between the two models is that the 850A uses BNCs for the channel inputs and the 850B uses screw terminals Figure 1 1 Trig Tek 850A Contact Chatter Detector Figure 1 2 Trig Tek 850B Contact Chatter Detector Timing Interval Controls provide for setting from 1 to 999 microseconds or 1 to 999 milliseconds for the maximum time a discontinuity can exist...

Страница 11: ...Terminal Permits FAULT Reset from remote location Fault Output Terminals Provide a 12 Volt for Fault and 0 for NO Fault for each channel Controls Power Switch Turns Power ON or OFF Contact Current Dial Permits continuous setting of 1 11 Operates in conjunction with the X1 X0 1 switch to provide 1 to 11 milliamps current through the contact being tested X1 X0 1 Switch Multiplies the current dial by...

Страница 12: ...h channel If a fault for the channel occurs the LED will illuminate and remain on until the RESET switch is depressed Power Power Operates from either 117 or 234 Volt RMS AC power 50 or 60 Hz at approximately 15 watts Astronics Test Systems Introduction 1 3 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Страница 13: ... User Manual Publication No 980972 Rev B This page intentionally left blank Introduction 1 4 Astronics Test Systems Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Страница 14: ... in the X0 1 position the dial sets 0 1 to 1 1 milliamps and the X1 position provides 1 to 11 milliamps The current setting is for all ten channels To prevent damage to the contacts each channel voltage is clamped below 3 Volts Time Interval Switch Settings The Time Interval Switches set the time discontinuity can exist in a NC contact before it is considered a FAULT for a NO contact the opposite ...

Страница 15: ...T LED for that channel illuminates and a 12 V signal is present on the FAULT output terminal on the rear panel To remove the fault the FAULT RESET switch should be depressed this removes the fault from all channels The FAULT RESET can be accomplished remotely by applying 12 volts to the RESET terminal on the rear panel Figure 2 1 Switch S1 Input Voltage Setting Switch S1 Operation 2 2 Astronics Te...

Страница 16: ...nts Remove top cover of the 850A B to access components Timing Interval Adjustment 1 Connect a frequency counter to Pin 3 of U3 Figure 3 1 2 Set the MICROSEC MILLISEC Switch to MICROSEC 3 Set the timing adjust R33 for an indication of 1 MHZ 10 kHz 4 Place the MICROSEC MILLISEC switch to MILLISEC 5 The counter should indicate 1000 10 Hz Figure 3 1 Calibration Adjustments Pin 1 U3 R32 R33 Astronics ...

Страница 17: ...R32 for 10 01 milliamps indication on the current meter 5 Connect the current meter to each of the other nine channels and get 10 0 2 milliamps indication 6 Place the X1 X0 1 Switch to X0 1 7 All channels should indicate 1 0 0 1 milliamps 8 Set dial to 5 and X1 X0 1 Switch to X1 9 All channels should indicate 5 0 0 1 milliamps Calibration 3 2 Astronics Test Systems Artisan Technology Group Quality...

Страница 18: ...l service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE INSPECTION Remotely inspect equipment before purchasing with our interactive website at www instraview com LOOKING FOR MORE INFORMATION Visit us on the web at www artisantg com for more information on ...