440
5.11.2
CWIND [2AH]: Window clearing
Function:
This command clears the window. The start and end point coordinates are
set by the parameters.
Sequence: Type 2
Parameters:
STX
1 byte
02H
CWIND
1 byte
2AH
Top left coordinate X
1 to 4 bytes
“0” to “4095”
Data delimiter
1 byte
“, “
Top left coordinate Y
1 to 4 bytes
“0” to “4095”
Data delimiter
1 byte
“, “
Bottom right
coordinate X 1
1 to 4 bytes
“0” to “4095”
Data delimiter
1 byte
“, “
Bottom right
coordinate Y 1
1 to 4 bytes
“0” to “4095”
ETX
1 byte
03H
Fig. 5-11-2