400
4.51
SWP [63H]: Window pattern coordinate registration
Function:
This command sends the center coordinates of Window pattern. This
becomes
valid when “Format E” is selected in window pattern editing The
command is sent to the designated program number. If the program number
is 0, it writes the data into the buffer RAM.
Sequence: Type 4
Command:
STX
1 byte
02H
SWP
1 byte
63H
Program number
1 to 3 bytes
“0” to “849”
ETX
1 byte
03H
Fig. 4-51-1
Data:
STX
1 byte
02H
TRDT
1 byte
10H
Window #1 horizontal
center position (%)
4 bytes
“0000” to “1000” = 0.000% to 100.0%
Window #1 vertical
center position (%)
4 bytes
“0000” to “1000” = 0.000% to 100.0%
Window #2 horizontal
center position (%)
4 bytes
“0000” to “1000” = 0.000% to 100.0%
Window #2 vertical
center position (%)
4 bytes
“0000” to “1000” = 0.000% to 100.0%
ETX
1 byte
03H
Fig. 4-51-2
*
Window #2 is not displayed if “0000” has been selected as the setting for the H and V
data of window #2.