background image

35

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

NOTE: Front Face Assembly with

barrier installed must be rein-

stalled prior to operation.

Front Glass Enclosure Panel, Removal 

and Installation

       WARNING 

Any safety screen or guard 

removed for servicing the appli-

ance must be replaced prior to 

operating the appliance.

       AVERTISSEMENT 

Tout écran ou protecteur retiré 

pour permettre l’entretien de 

l’appareil doit être remis en 

place avant de mettre l’appareil 

en marche.

       WARNING 

• Do not attempt to substitute the 

materials used on this door, or 

replace cracked or broken glass. 

• Handle this glass with extreme 

care! Glass is susceptible to 

damage – Do not scratch or 

handle roughly while reinstall-

ing the glass door frame.

• The glass door(s) of this appli-

ance must only be replaced as a 

complete unit as provided by the 

manufacturer.  Do not attempt 

to replace broken, cracked or 

chipped glass separately. 

• Do not attempt to touch the front 

enclosure glass with your hands 

while the fireplace is in use.

       WARNING 

Do not operate appliance with 

the glass front removed, cracked 

or broken.

       AVERTISSEMENT 

Ne pas utiliser l'appareil si le 

panneau frontal en verre n'est 

pas en place, est craqué ou 

brisé.  

Only doors certified with the appliance 

shall be used.

Seules des portes certifiées pour cet 

appareil doivent être utilisées.

WARNING: DO NOT abuse glass door by 

striking or slamming shut.

These are B-vent appliances. They are designed 

to operate only when the glass enclosure panels 

are installed. Generally the glass enclosure panels 

should not be removed except to gain access to 

the components within the firebox. 

Removing Glass Enclosure Panels

(see 

Figure 43

)

To access the glass door securing latches, first

remove the hood by pulling firmly straight away

from the unit. Remove the front face assembly by

lifting up top and bottom evenly approximately

1/2" and pulling straight out from the unit once

the brackets are disengaged.

Remove the bottom compartment door by 

sliding the hinge pin, located at the door’s left 

side, to the right until it disengages from the 

left corner post hole. Pull the door diagonally 

to the left, away from the fireplace.

Locate the latch at the top of the control com-

partment and disengage them from the door 

frame bottom vee-flange, pulling down on its 

handle to open it.

Installing Glass Enclosure Panel

(see Figure 43)

Retrieve the glass door. Visually inspect the 

gasket on the backside of the frame. Gasket 

surface must be clean, free of irregularities 

and seated firmly. 

Position the door in front of the firebox opening 

with the bottom of the door held away from the 

fireplace 

(Figure 43)

.  Hook the top flange of the 

door frame over the top of the firebox frame. 

Let the bottom of the door frame swing gently 

in towards the fireplace ensuring that the gasket 

seats evenly as the door frame draws shut. 

Fasten the latch located underneath the firebox 

floor to the door's vee-flange. Close both the 

latch securely.

Figure 43 

Glass 

Door Latch

Front Glass

Enclosure Panel

Firebox Floor

Bottom Vee-flange

Glass Door Frame

Top Flange

Glass Door Frame

NOTE:  When installing the glass door, ensure the 

spacing on both sides is even and equal.

Содержание Marin40STTMN

Страница 1: ...ut tre converti d autres gaz sauf si une trousse de conversion est utils e Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO...

Страница 2: ...HER LA VITRE L cran pare tincelles fourni avec ce foyer r duit le risque de br lure en cas de contact accidentel avec la vitre chaude et doit tre install pour la protection Des enfants et Des personne...

Страница 3: ...gaalosni osalejadosde lachimeneaenfuncionamiento Superviseenformacercanaalos ni osencualquiercuartodondehaya unachimeneafuncionandopara impedirelcontactoconelvidrio Mantenga la ropa mobiliario gasolin...

Страница 4: ...appliance For use with barrier s Part No s J7420 INTRODUCTION The Millivolt appliances have a millivolt gas control valve with piezo ignition system If any optional accessories that will require elect...

Страница 5: ...h the National Fuel Gas Code ANSI Z223 1 NFPA 54 latest edition InCanada thecurrentCAN CGA B149 1 installation code The appliance when installed must be electri cally grounded and wired in accordance...

Страница 6: ...ERSION SHALL BE CAR RIED OUT BY A MANUFACTURER S AUTHO RIZED REPRESENTATIVE IN ACCORDANCE WITH THE REQUIREMENTS OF THE MANU FACTURER PROVINCIAL OR TERRITORIAL AUTHORITIES HAVING JURISDICTION AND IN AC...

Страница 7: ...ce should be located out of traffic and away from furniture and draperies Figure 3 En raison des temp ratures lev es l appareildevrait treinstall dansunendroit o il y a peu de circulation et loin du m...

Страница 8: ...1 NFPA 54 CAN CGA B149 1 Multiple Terminations These appliances may vent adjacent to and at the same level with any other gas appliances includingdirect ventappliances providedthat thereisatleast2ft 0...

Страница 9: ...tible materials may be installed at any height above the appliance opening however donotallowanythingtohangbelowthefireplacehood Minimumclearancerequirementsincludeanyprojectionssuchasshelves window s...

Страница 10: ...to appliance location Step 3 Page 13 Install the vent system and exterior termination Step 4 Page 14 Field Wiring a Millivolt Appliances The operating control switch is factory installed Step 5 Page 1...

Страница 11: ...r level a solid continuous platform must be constructed Headers may be in direct contact with the appliance top spacers but must not be supported by them or notched to fit around them All construction...

Страница 12: ...WALL BRACKET Front and back edge of unit top Stepped to accept drywall on all four corners NOTE Unit has a factory installed vent seal cap and vent cover plate see Figures 22 and 23 on page 15 in eac...

Страница 13: ...areful that the pipe compound does not get inside the pipe It is recommended to install a sediment trap in the supply line as close as possible to the appliance Appliances using Propane should have a...

Страница 14: ...olswitchwithinthemillivoltcontrolcircuit as shown in Figure 16 using the 15 feet of 2 conductor wire supplied route wires through the snap bushing to the optional control switch Mount the optional con...

Страница 15: ...er control compartment door on the side opposite the valve lifts on and off The millivolt control valve has a 3 8 10mm NPT thread inlet port Secure all joints tightly using appropriate toolsandsealing...

Страница 16: ...d crawlspace not considered part of the living area of the home NOTE Do not terminate outside air kit in attic space under any circumstances CAUTION NEVER LOCATE INLET WHERE IT CANBEBLOCKEDBYSHRUBS SN...

Страница 17: ...d clean out the ports With gas line installed run initial system checkout before closing up the front of the unit Follow the pilot lighting instructions providedintheCareandOperationInstructions manua...

Страница 18: ...lite will NOT be used See Figure 26 DO NOT PLACE ANY VERMICULITE ON THE BURNER NOTE This appliance is provided with enough Glowing Embers for several applications do not use all that is in a new bag a...

Страница 19: ...he Groove At The Bottom Of Log 1 Over The Grate And Slide It Forward Against The Grate Here Position Log 2 Over The Grate Bar And Slide It Against The Back Of The Grate Here Position Groove At The Bot...

Страница 20: ...wo Charred Spots Face The Front Position The Groove In The Back Of Log 3 Against The Grate Rest Log 5 Against The Grate Here Log 5 Sits In Front Of The Grate STEP 5 NOTICE Marin model fireplaces inclu...

Страница 21: ...the bottom of the door frame swing gently in towards the fireplace ensuring that the gasket seats evenly as the door frame draws shut Fasten the latch located underneath the firebox floor to the door...

Страница 22: ...r Clearances Figure 32 Finishing Requirements This Area Must Remain Clear of Combustible Materials Top of Appliance 1 Min 25 mm Combustible Wall Framing Spacer Clean Face Models Top of Door Frame Hood...

Страница 23: ...s safety limit switch First allow the appli ance to cool then reset the safety switch by pushing the red reset button on the back of the switch To access the blocked flue safety limit switch refer to...

Страница 24: ...usement pour liminer la poussi re et les traces de graisse ou d huile Collez l tiquette sur le bo tier de la t l commande Figure B Choisissez la langue qui est principale ment parl e dans la r sidence...

Страница 25: ...door diagonally to the left away from the fireplace Remove the modesty panel by pulling the bottom right corner of the modesty panel out slightly to disengage the snap fit feature lift the modesty pa...

Страница 26: ...ld side pressure test fitting and verify manifold pressure reads 3 5 water column 0 87 kPa for natural gas and 10 0 water column 2 49 kPa for propane gas Step 6 Refer to Figure 36 and remove the pilot...

Страница 27: ...tact avec la surface chaude Il est recommand d installer une barri re physique si des personnes risques habitent la maison Pour emp cher l acc s un foyer ou un po le installez une barri re de s curit...

Страница 28: ...ans la r sidence du propri taire En cas de doute collez l tiquette en anglais 2 Si une t l commande est utilis e pour contr ler le foyer nettoyez la soigneusement pour liminer la poussi re et les trac...

Страница 29: ...nvertible for use with other gases unless a certified kit is used These appliances are designed to operate on natural gas or propane gas only The use of other fuels or combinations of fuels will degra...

Страница 30: ...ess The glass should be kept clean during thefirsttwoweeksofusetopreventthefilmfrom baking on making it very difficult to remove See Cleaning Glass on Page 35 Orifice Sizes Sea Level to High Altitude...

Страница 31: ...On millivolt systems the piezo igniter Hi Lo flame adjustment knob and pilot and main gas ON OFF control knob are located on the modesty panel The gas valve is located behind the modesty panel See Fig...

Страница 32: ...l Knob IN OUT SIT Millivolt Gas Valve Outside Combustion Air Controls Manyappliancesareequipped wheninstalled with an outside make up air vent system that is designed to provide the appliance with out...

Страница 33: ...is safety limit switch First allow the appliance to cool then reset the safety switch by pushing the red reset button on it A To access the blocked flue safety switch 1 Remove the hood by pulling stra...

Страница 34: ...alified service technician inspectionshouldincludeensuringthatventing system is unobstructed and vent components are properly assembled and not damaged Homeowner must contact a qualified service techn...

Страница 35: ...d Generallytheglassenclosurepanels should not be removed except to gain access to the components within the firebox Removing Glass Enclosure Panels see Figure 43 To access the glass door securing latc...

Страница 36: ...be used See Figure 8 DO NOT PLACE ANY VERMICULITE ON THE BURNER NOTE This appliance is provided with enough Glowing Embers for several applications do not use all that is in a new bag at one time For...

Страница 37: ...rt Bracket Position The Groove At The Bottom Of Log 1 Over The Grate And Slide It Forward Against The Grate Here Position Log 2 Over The Grate Bar And Slide It Against The Back Of The Grate Here Posit...

Страница 38: ...55M20 4 Log Rear Right 55M21 5 Log Front Center 55M22 6 Log Center Top 55M23 2 6 5 4 1 3 Figure 47 3 Grate Assembly 5 Position Small End Of Log 6 On The Notch Of Log 3 Here 6 4 Position The Round End...

Страница 39: ...two extremes Air Shutter Adjustment Guidelines Amount of Primary Air Flame Color Air Shutter Adjustment If air shutter is closed too far Flame will be orange Air shutter gap should be increased If ai...

Страница 40: ...closed position until the proper flame appear ance is achieved 4 Leave the control knob off pilot on in the ON position millivolt appliances and the burner OFF ON switch OFF and remote switches if app...

Страница 41: ...__________________________________________ ____________________________________________________________________ Parts will be shipped at prevailing prices at time of order When ordering repair parts a...

Страница 42: ...sareavailablewithduct FOAK 4 and without duct FOAK 4LD for use if outside combustion air is required or desired If model FOAK 4LDisuseditmustbeusedinconjunction with locally purchased non combustible...

Страница 43: ...The brickaded liner kits include ceramic panels as shown here The panels have brick like features in relief ACCESSORY COMPONENTS CONTINUED H0779 Top Vent Brickaded Panel Liner Kits Model Number Catal...

Страница 44: ...terior portions of the system being exposed to cold weather Also inspect wall straps or plumbers s tape to ensure it is secure and in place Appliance Checkout Qualified Service Technician Perform the...

Страница 45: ...UCTIONS TO TURN OFF GAS TO APPLIANCE If the pilot will not stay lit after several tries turn the gas control knob to OFF and call your service technician or gas supplier 10 Turn gas control knob count...

Страница 46: ...leuse ne reste pas allum e apr s plusieurs tentatives r glez la manette d admission du gaz la position OFF et appelez un technicien qualifi ou le fournisseur de gaz 10 Tournez le bouton de r glage du...

Страница 47: ...Figures50onPage40 Cleanand oradjustpilot for maximum flame impingement on thermocouple Ensure that the connection between the valve and thermocouple are tight and secure 3 Pilot burning no gas to burn...

Страница 48: ...Black 40 J7536 2 2 Glass Enclosure Assembly 40 H6365 2 3 Log Set 55M04 1 4 Bag of Vermiculite H6319 1 5 Bag of Embers Rockwool 88L53 1 6 Bag of Decorative Volcanic Stone 80L42 1 7 Burner Assembly H62...

Страница 49: ...49 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE 2 7 10 16 22 17 18 8 23 9 20 21 5 3 19 12 4 11 Inside Location 15 NOTE See the tables on Page 48 for replacement parts applicables REPLACEMENT PARTS 13...

Страница 50: ...50 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE NOTES...

Страница 51: ...and tear accident riot fire flood or acts of God b damages caused by abuse negligence misuse or unauthorized alteration or repair of the Product affecting its stability or performance The Product mus...

Страница 52: ...5 Innovative Hearth Products Astria MarinTN B Vent Gas Fireplace P900301 01 Innovative Hearth Products reserves the right to make changes at any time without notice in design materials specifications...

Отзывы: