background image

www.Astria.US.com

126637-01B

18

INSTALLING GLASS DOORS

Spring  clips  have  been  installed  but  some 

adjustments may be needed. Install the doors 

using the following steps:
1.  With bifold doors completely folded, insert 

bottom  pivot  pin  into  pivot  hole  located 

near bottom corner of front face opening 

and swing door to vertical position making 

sure top pins slide into door track. Door 

is installed when top door pin snaps into 

spring clip.

2.  Repeat step 1 for remaining door.
If you find the doors do not close properly or 

do not appear level or straight, proceed with 

section on door adjustment,

Figure 29 - Installing Bi-Fold Doors

Spring 

Clip

Insert Pin 

into Spring 

Clip

Pivot 

Hole

Insert 

Bottom 

Pivot Pin 

into Hole

Fold Door 

and Slide 

Top Pins 

Into Track

Figure 30 - Adjusting Bi-Fold Doors

GLASS DOOR INSTALLATION

Continued

DOOR ADJUSTMENT

Remove doors and slightly loosen lower pivot 

clips and upper spring clips. Replace doors 

and  fully  close  them.  Use  1/8"  shims  (any 

material) to level doors. Once proper setting 

is achieved, carefully open doors enough so 

that you can access spring clips with a phillips 

screwdriver. Tighten screws. See Figure 30.

OPERATION AND MAINTENANCE GUIDELINES

GLASS DOORS

Glass  doors  are  optional  with  the  fireplace. 

When fireplace is in operation, doors must be 

fully opened or fully closed position only or a 

fire hazard may be created (see Figure 31, 

page 19).
A fireplace equipped with glass doors operates 

much differently than a fireplace with an open 

front. A fireplace with glass doors has a limited 

amount of air for combustion.
Excessive heat within the fireplace can result if 

too large a fire is built or if combustion air gate 

is not completely open. The following tips should 

be followed to assure that both the fireplace 

and glass door retain their beauty and function 

properly. Both the flue damper and glass doors 

must be fully opened before starting fire. This will 

provide sufficient combustion air and maintain 

safe temperatures in firebox.

IMPORTANT:

 The glass must be allowed to 

warm slowly and evenly. The tempered glass will 

withstand a gradual temperature rise to 550° F, 

which is more than a normal fire will generate. 

Such materials as pitch/wax laden logs, very dry 

mill end lumber and large amounts of paper or 

cardboard boxes can create an excessively hot 

fire and should not be burned in this fireplace. 

Always keep the fire well back from the doors 

and never allow flames to contact the glass.

Содержание Georgian 36

Страница 1: ...on the rating plate This appliance is not convertible for use with other gases unless a certified kit is used WARNING If the information in these instructions is not followed exactly a fire or explosi...

Страница 2: ...ce and refer to fire log warnings and caution markings on packaging prior to use Thisfireplaceisnotintendedtobe used as a substitute for a furnace to heat an entire home Use for supplemental heat only...

Страница 3: ...L 29 14 1 2 22 1 2 26 5 8 4 1 2 15 5 8 4 1 2 1 58 7 1 4 11 15 1 4 3 1 2 9 1 2 10 1 2 67 61 49 11 7 30 1 45 1 8 36 OUTSIDE AIR ACCESS GAS LINE ACCESS 36 HEARTH 1 1 4 20 1 4 Ref 35 1 4 19 22 1 2 Figure...

Страница 4: ...IONS Continued 42 MODEL 22 3 4 30 1 2 29 4 3 8 15 3 4 5 8 17 5 8 67 61 49 7 1 30 11 58 42 51 1 8 4 1 2 3 1 2 9 1 2 10 1 2 81 2 13 17 OUTSIDE AIR ACCESS GAS LINE ACCESS 42 HEARTH 1 1 4 23 Ref 41 3 8 26...

Страница 5: ...ICATIONS Continued 50 MODEL 38 1 2 28 1 2 43 8 17 5 8 19 1 4 24 49 30 11 61 67 58 7 1 59 50 4 1 2 3 1 2 9 1 2 10 1 2 8 1 2 13 17 GAS LINE ACCESS OUTSIDE AIR ACCESS 50 HEARTH 1 1 4 23 Ref 49 3 8 34 3 8...

Страница 6: ...36 Models Maintain 1 1 2 Clearance at Sides and Back of Fireplace 1 1 2 Clearance Not Required at Nailing Flanges Figure 5 Corner Installation SELECTING LOCATION To determine the safest and most effi...

Страница 7: ...ued Figure 6 Hearth Extension Seal Gap Fireplace Front Ember Protector Fireplace Front Raised Hearth Fireplace Front Elevated Ember Protector Ember Protector Seal Gap Hearth Extension MANTELS Amantel...

Страница 8: ...gure 8 Outside Air Kit Secure to Collars with Metal Tape Screws or Straps Min of 1 4 x 20 in size Air Inlet Location Must Allow For Bushes or Snow Vent Hood Required for Wall Installation Air Inlet Ey...

Страница 9: ...gether it is important to assure the joint between the chimney sections is locked Check by pulling chimney upward after locking The chimney will not come apart Figure 10 Elbow Offset B A Screws if pro...

Страница 10: ...gure 14 Firestop Spacer with Attic Space Above Ceiling Existing Ceiling Frame Firestop Spacer Screws or Staples Min of 8 Firestop Spacer Screws or Staples Min of 8 PENETRATING ROOF To maintain a 1 36...

Страница 11: ...tom Overlap Shingles Top and Sides Only Figure 16 Flashing Installation FLASHING INSTALLATION V6F 10DM OR V12F 10DM Determine the flashing to be used with the roof opening chart Slide flashing over pi...

Страница 12: ...Min 10 3 Min 2 Min 3 Min Level of Flue Gas Outlet Figure 20 10 Foot Rule Terminations Spark Arrestor The fireplace system must be terminated with the listed round top or chase terminations In any cas...

Страница 13: ...brick panel Grate retaining bracket should be positioned as shown in Figure 21 WARNING LIFTING HAZARD SINGLE PERSON LIFT COULD CAUSE INJURY USE ASSISTANCE WHEN MOVING OR LIFTING Figure 22 Installing...

Страница 14: ...verall length of piping bag should be about 16 If the bag is longer than 16 cut it down to size by removing end with larger opening This will make the bag easier to handle 4 Put grout mixture into pip...

Страница 15: ...page 20 This grate has been designed to keep the operation of your fireplace safe and efficient FIREBRICK WALL INSTALLATION Continued Figure 24 Installing Grate Retainers INSTALLING SCREEN 1 Slide ro...

Страница 16: ...apply soap and water solution to all connectionsandjoints Bubbles forming show a leak Correct all leaks at once DO NOT USE AN OPEN FLAME FOR LEAK TESTING AND DO NOT OPER ATEANYAPPLIANCE IFALEAK IS DE...

Страница 17: ...ntinued GLASS DOOR INSTALLATION Figure 28 Installing Bottom Door Frame Hex Screw Bottom Door Frame Figure 27 Installing Top Door Frame Top Door Frame Smoke Shelf Ash Lip Ash Lip DOOR FRAME MODELS BDMO...

Страница 18: ...ver Tighten screws See Figure 30 OPERATION AND MAINTENANCE GUIDELINES GLASS DOORS Glass doors are optional with the fireplace When fireplace is in operation doors must be fully opened or fully closed...

Страница 19: ...isks of both fire and smoke Cleaning Glass Clean glass with any commercial glass cleaner or soap and water Do not use any abrasive material to clean glass Do not clean glass with any cool water if gla...

Страница 20: ...www Astria US com 126637 01B 20 PARTS MODELS 36 42 AND 50 1 21 20 5 6 7 10 9 11 12 13 16 17 15 14 8 24 23 3 25 18 2 22 19 4...

Страница 21: ...duit One 2 17 109752 02 Conduit Two 2 18 Heat Shield Support 1 19 123298 02 Ash Box Assembly 1 20 Inner Dome Assembly 1 21 Smoke Shield 1 22 Damper Control Bracket 1 23 109457 03 Screen 36 2 109457 02...

Страница 22: ...aic42M4 Ivory Split Stacked F0345 Mosaic42M3 Red Herr Full Stack F0346 Mosaic42M5 Red Herr Split Stack F0347 Mosaic42M3 Ivory Herr Full Stack F0348 Mosaic42M5 Ivory Herr Split Stack F0348 Mosaic50M2 R...

Страница 23: ...r F0368 Estate42P2 Stacked Gray F0369 Estate42P3 Herringbone Rust F0370 Estate42P3 Herringbone Cappuccino F0371 Estate42P3 Herringbone Creamer F0372 Estate42P3 Herringbone Gray F0373 Estate50P2 Stacke...

Страница 24: ...MENT PARTS If this product is missing a part or has a broken component please do not return it to the store Call INNOVATIVE HEARTH PRODUCTS at 1 800 655 2008 to answer questions and replace parts unde...

Страница 25: ...42 Ebony BDMO42G 42 Pewter BDMO42C 42 Oiled Bronze BDMO50E 50 Ebony BDMO50G 50 Pewter BDMO50C 50 Oiled Bronze DOUBLE WALL PIPE 12 12DM 18 12DM 24 12DM 36 12DM 48 12DM 12 12HT 18 12HT 24 12HT 36 12HT...

Страница 26: ...ch V12F 10DM 6 12 to 12 12 Pitch ACCESSORIES Continued SQUARE CHASE TOP TERMINATION STL 12D AND STL 12DMP BLACK ROUND TOP TERMINATIONS RLT 12D AND RLT 12HT STORM COLLAR SC2 1 FIRESTOP SPACER FS 10 AND...

Страница 27: ...12HT 48 Section Double Wall Pipe 30E 12HT 30 Offset and Return 12S 12HT Chimney Support RLT 12HT Round Top with Louvers AP 12HT Anchor Plate Collar Assembly Masonry CAK 12 Cold Air Collar Kit When ord...

Страница 28: ...gas Fuel products with abnormal burning characteristics including but not limited to fuel such as driftwood coal or plywood and wood products using a binder may burn at excessive temperatures and may...

Страница 29: ...RANTY Model located on product or identification tag ______________________________ Serial No located on product or identification tag ___________________________ Date Purchased ______________________...

Страница 30: ...www Astria US com 126637 01B 30 NOTES...

Страница 31: ...www Astria US com 126637 01B 31 NOTES...

Страница 32: ...126637 01A Rev B 02 14 1508 Elm Hill Pike Suite 108 Nashville TN 37210 1 800 655 2008 www IHP US com P126637 01...

Отзывы: