background image

Astria.US.com

126650-01B

2

Safety .............................................................................................2

Product Dimensions ......................................................................4

Fireplace Installation ......................................................................5

Venting Installation ........................................................................7

Optional Gas Line Installation ......................................................13

Operation and Maintenance Guidelines ........................................14

Replacement Parts .......................................................................15

Technical Service .........................................................................15

Fireplace Accessories ...................................................................16

Installation Accessories ...............................................................16

Important Notices ........................................................................18

Warranty ......................................................................................19

Thank you for your purchase. We appreciate your 

business!

Please carefully read and follow all instructions in this manual. 

Pay 

special attention to all warnings and safety information.

Following these safety, care, and operation instructions will help 

ensure many years of dependable and enjoyable service from your 

fireplace.

Register your product online today!

To help us keep you up-to-date on product information and of-

fers, please take a few moments to register your product online 

at Astria.US.com

Please read and understand these instructions before installing 

or operating.

SAFETY

 WARNING: Improper installation, adjustment, 

alteration, service or maintenance can cause injury, 

property damage or loss of life. Refer to this manual 

for assistance or additional information. Consult a 

qualified installer or local distributor.

IMPORTANT: Check local codes before installing this 

fireplace.

This fireplace model is a wood burning fireplace intended and ap-

proved for installation in either residential homes or buildings of 

standard construction. This fireplace system requires the utilization 

of INNOVATIVE HEARTH PRODUCTS, LLC’s (IHP) 8", double-wall, 

and snap lock flue pipe system. 
Glass doors are optional with this fireplace and come in different 

styles. For more information see Glass Doors, page 14). Optional 

glass doors in several finishes are available for this fireplace (see 

Replacement Parts, page 15 and Accessories on page 16).
Before beginning installation of this fireplace, read these instructions 

through completely.

•  This  IHP  fireplace  and  its  components  are  safe  when  installed 

according to this installation manual. Unless you use IHP com-

ponents, which have been designed and tested for the fireplace 

system, you may cause a fire hazard.

•  The IHP warranty will be voided by and IHP disclaims any respon

-

sibility for the following actions.

a. Modification of the fireplace or any of the components manu-

factured by IHP unless otherwise permitted by IHP.
b. Use of any component part not manufactured or approved by 

IHP in combination with an IHP fireplace system.
c. Installation and/or operation in a manner other than instructed 

in this manual.
d. The burning of any other fuel not tested or approved by IHP  

in this wood burning fireplace.

Proper installation is the most important step in ensuring safe and 

continuous operation of the fireplace. Consult the local building codes 

as to the particular requirements concerned with the installation of 

TABLE OF CONTENTS

all factory built fireplaces.
Proper installation is the most important step in ensuring safe and 

continuous operation of the fireplace. Although grounding may not 

be required by code in your area, it must be electrically grounded in 

accordance with local codes or, in the absence of local codes, with 

the National Electrical Code, ANSI/NFPA 70-1990.
This firebox is intended for installation in accordance with the National 

Fire Protection Association Standard for Chimneys, Fireplaces, Vents 

and Solid-Fuel Burning Fireplaces, NFPA 211, and in accordance 

with codes such as the BOCA Basic/National Code, the Standard 

Mechanical Code, and the Uniform Building Code.

 WARNING: Do not install a fireplace insert in this 

fireplace unless the manufacturer's instructions with 

the insert specifically state this fireplace has been 

tested for use with this insert.

FOR YOUR SAFETY

• Do not store or use gasoline or any other flammable 

vapors or liquids in the vicinity of this or any other 

appliance.

• Due to high temperatures, the appliance should be 

located out of traffic and away from furniture and 

draperies.

• Do not place clothing or other flammable materials 

on or near the appliance.

• Never  leave  children  unattended  when  a  fire  is 

burning in the fireplace.

 WARNING: Use solid wood or processed solid 

fuel fire logs only. Do not poke or stir the logs while 

they are burning. Use only firelogs that have been 

evaluated for the application in fireplace and refer to 

firelog warnings and caution markings on packaging 

prior to use.

Содержание Craftsman STP2

Страница 1: ...r approved to ANS Z21 11 2 standard An INNOVATIVE HEARTH PRODUCTS LLC hood must be installed when using a vent free log heater see Ac cessories page 17 FOR CANADA The authority having jurisdiction suc...

Страница 2: ...hazard The IHP warranty will be voided by and IHP disclaims any respon sibility for the following actions a Modification of the fireplace or any of the components manu factured by IHP unless otherwise...

Страница 3: ...urn veryquickly DONOTusetreatedwood charcoal coal trash driftwoodorwoodsthathavebeendippedintar pitch pine tar creosote etc Wood products made with synthetic binders such as plywood produce ab normall...

Страница 4: ...ce the risk of a chimney fire SAFETY Continued Figure 1 Dimensions WARNING Always leave glass doors fully opened or fully closed when operating fireplace WARNING Children and adults should be alerted...

Страница 5: ...2 Common Location of Fireplace Existing Wall Projected Wall 12 30 4 cm to Perpendicular Wall MINIMUM CLEARANCE TO COMBUSTIBLES Back and sides of fireplace 1 minimum Adjacent wall 12 minimum Chimney ou...

Страница 6: ...From Outer Pipes to Combustibles 1 2 5 cm Min To Combustibles 21 5 16 54 cm 42 5 8 108 cm 24 61 cm 12 31 cm Figure 7 Framing Firebox with Z Type Ember Protectors As Required by Design as Long as Ceil...

Страница 7: ...age 16 Avoid installing outside air eyebrow in areas where inlet opening may be blocked by snow bushes or other obstacles It should also be located beyond the reach of children CAUTION Combustion air...

Страница 8: ...r pipe and a wire spacer Each section of pipe comes in lengths of 12 18 36 and 48 The actual lineal gain for each is measured after each section is fully connected Lineal gain is the actual measurable...

Страница 9: ...e19 Figure 18 Raise and Offset B A Screws Figure 16 Elbow Offset 20 FT 6 096m 20 FT 6 096m Return Elbow 12S 8DM Support Required Figure 17 Chimney Supports 2 5 1cm Minimum Straps 2 5 1cm Minimum Angle...

Страница 10: ...tances such as neighboring hills tall trees or strong wind areas can cause down drafts in chimney system In such cases going beyond the minimum recommended height would be preferable to provide a bett...

Страница 11: ...ed to cover exposed area and flashing base Secure in position by nailing through shingles see Figure 23 DO NOT NAIL THROUGH FLASHING CONE Nail Only Outer Perimeter of Flashing Storm Collar Underlap Sh...

Страница 12: ...al may be used for facing glass tile brick etc as long as proper clearances are adhered to and firebox openings are not obstructed in any way see Figure 27 Use only heat resistant noncombustible morta...

Страница 13: ...s line and refractory knockout hole with refractory cement or commercial furnace cement Install the gas appliance or cap off gas line if desired CAUTION All gas piping and connections must be tested f...

Страница 14: ...e 30 Cabinet Glass Doors Cabinet Glass Doors WARNING FIREPLACESEQUIPPEDWITHDOORS SHOULD BE OPERATED ONLY WITH DOORS FULLY OPENORDOORSFULLYCLOSED IFDOORSARELEFT PARTLYOPEN GASANDFLAMEMAYBEDRAWNOUT OF T...

Страница 15: ...s fireplace OPERATION AND MAINTENANCE GUIDELINES Continued REPLACEMENT PARTS See Page 16 Fireplace Accessories section for replacement parts Use only parts supplied from the manufacturer Normally all...

Страница 16: ...1 side Platinum Finish J0455 DG368ST 36 See Thru WB Bi Fold Door 1 side Brushed Finish DOUBLE WALL PIPE F0895 12 8DM 12 Section Double Wall Pipe Snap Lock F0896 18 8DM 18 Section Double Wall Pipe Snap...

Страница 17: ...SQUARE TOP TERMINATION F0922 ETO 8DM Square Top with Mesh MESH SQUARE TOP TERMINATION WITH SLIP SECTION F0923 ETLO 8DM Square Top with Mesh and Slip Section ADJUSTABLE HOOD Required when installing a...

Страница 18: ...8HT 36 Section Hi Temp Double Wall Pipe Snap Lock F0885 48 8HT 48 Section Hi Temp Double Wall Pipe Snap Lock F0886 30E 8HT 30 Degree Hi Temp Offset and Return F0887 12S 8HT Hi Temp Chimney Support For...

Страница 19: ...r propane gas Fuel products with abnormal burning characteristics including but not limited to fuel such as driftwood coal or plywood and wood products using a binder may burn at excessive temperature...

Страница 20: ...ecolors stylesandproducts Consult your local distributor for fireplace code information Printed in U S A 2013 IHP LLC P N 126650 01 Rev B 10 2015 P126650 01 1508 Elm Hill Pike Suite 108 Nashville TN 3...