INSTALLATION ACCESSORIES 

Continued

STORM COLLAR

F0915

SC1-1

Storm Collar 

FIRESTOP SPACER

F0907

3600FS-8DM-1 1" Clearance Firestop Spacer ( 1ea.)

F0904

FS-8DM

2" Clearance Firestop Spacer (1 ea.)

ROOF FLASHING

F0909

V6F-8DM

Roof Flashing 0 to 6/12 Pitch (30" Base)

F0910

V12F-8DM

Roof Flashing 6/12 to12/12 Pitch

ROUND TOP TERMINATIONS 

F0918

RLT-8DM

Round Top with Louvered Screen

F0890

RLT-8HT

Hi-Temp Round Top with Louvered Screen

ROUND TOP TERMINATIONS WITH W/SLIP SECTION

F0919

RLTT-8DM

Round Top with Slip Section & Louvers

F0891

RLTT-8HT

Hi-Temp Round Top w/Lvrd. Screen and Slip Section

SQUARE TOP TERMINATION WITH LOUVERS AND SLIP SECTION

F0921

ETL-8DM

Square Top with Slip Section

F0893

ETL-8HT

Hi-Temp Large Pyramid Top with Slip Section

MESH SQUARE TOP TERMINATION

F0922

ETO-8DM

Square Top with Mesh

MESH SQUARE TOP TERMINATION WITH SLIP SECTION

F0923

ETLO-8DM

Square Top with Mesh and Slip Section

ADJUSTABLE HOOD

Required when installing a vent-free gas log in this fireplace.

F1764

GA6050

Black Fireplace Hood

FIRESTOP THIMBLE

F0911

38FST

Firestop Thimble ( Use when penetrating a joist)

F0912

FST30

Firestop Thimble ( Use when offsetting through a joist)

HIGHT TEMPERATURE TOUCH-UP PAINT

(Not Shown)

J3943

Kit Touch-Up paint

LABEL-UL127-50PK

 WARNING

 

   HOT

• 

Fire Risk

• 

Insulation and combustibles must not touch 

pipe

• 

Consult manual for clearance requirements

• 

Ensure proper connection

 WARNING

 

   HOT

• 

Fire Risk

• 

Insulation and combustibles must not touch 

pipe

• 

Consult manual for clearance requirements

• 

Ensure proper connection

 WARNING

 

   HOT

• 

Fire Risk

• 

Insulation and combustibles must not touch 

pipe

• 

Consult manual for clearance requirements

• 

Ensure proper connection

900599-01

F2659

LABEL-UL127-

50PK

UL127 Venting Label - 50 PK

Содержание Craftsman STP2

Страница 1: ...r approved to ANS Z21 11 2 standard An INNOVATIVE HEARTH PRODUCTS LLC hood must be installed when using a vent free log heater see Ac cessories page 17 FOR CANADA The authority having jurisdiction suc...

Страница 2: ...hazard The IHP warranty will be voided by and IHP disclaims any respon sibility for the following actions a Modification of the fireplace or any of the components manu factured by IHP unless otherwise...

Страница 3: ...urn veryquickly DONOTusetreatedwood charcoal coal trash driftwoodorwoodsthathavebeendippedintar pitch pine tar creosote etc Wood products made with synthetic binders such as plywood produce ab normall...

Страница 4: ...ce the risk of a chimney fire SAFETY Continued Figure 1 Dimensions WARNING Always leave glass doors fully opened or fully closed when operating fireplace WARNING Children and adults should be alerted...

Страница 5: ...2 Common Location of Fireplace Existing Wall Projected Wall 12 30 4 cm to Perpendicular Wall MINIMUM CLEARANCE TO COMBUSTIBLES Back and sides of fireplace 1 minimum Adjacent wall 12 minimum Chimney ou...

Страница 6: ...From Outer Pipes to Combustibles 1 2 5 cm Min To Combustibles 21 5 16 54 cm 42 5 8 108 cm 24 61 cm 12 31 cm Figure 7 Framing Firebox with Z Type Ember Protectors As Required by Design as Long as Ceil...

Страница 7: ...age 16 Avoid installing outside air eyebrow in areas where inlet opening may be blocked by snow bushes or other obstacles It should also be located beyond the reach of children CAUTION Combustion air...

Страница 8: ...r pipe and a wire spacer Each section of pipe comes in lengths of 12 18 36 and 48 The actual lineal gain for each is measured after each section is fully connected Lineal gain is the actual measurable...

Страница 9: ...e19 Figure 18 Raise and Offset B A Screws Figure 16 Elbow Offset 20 FT 6 096m 20 FT 6 096m Return Elbow 12S 8DM Support Required Figure 17 Chimney Supports 2 5 1cm Minimum Straps 2 5 1cm Minimum Angle...

Страница 10: ...tances such as neighboring hills tall trees or strong wind areas can cause down drafts in chimney system In such cases going beyond the minimum recommended height would be preferable to provide a bett...

Страница 11: ...ed to cover exposed area and flashing base Secure in position by nailing through shingles see Figure 23 DO NOT NAIL THROUGH FLASHING CONE Nail Only Outer Perimeter of Flashing Storm Collar Underlap Sh...

Страница 12: ...al may be used for facing glass tile brick etc as long as proper clearances are adhered to and firebox openings are not obstructed in any way see Figure 27 Use only heat resistant noncombustible morta...

Страница 13: ...s line and refractory knockout hole with refractory cement or commercial furnace cement Install the gas appliance or cap off gas line if desired CAUTION All gas piping and connections must be tested f...

Страница 14: ...e 30 Cabinet Glass Doors Cabinet Glass Doors WARNING FIREPLACESEQUIPPEDWITHDOORS SHOULD BE OPERATED ONLY WITH DOORS FULLY OPENORDOORSFULLYCLOSED IFDOORSARELEFT PARTLYOPEN GASANDFLAMEMAYBEDRAWNOUT OF T...

Страница 15: ...s fireplace OPERATION AND MAINTENANCE GUIDELINES Continued REPLACEMENT PARTS See Page 16 Fireplace Accessories section for replacement parts Use only parts supplied from the manufacturer Normally all...

Страница 16: ...1 side Platinum Finish J0455 DG368ST 36 See Thru WB Bi Fold Door 1 side Brushed Finish DOUBLE WALL PIPE F0895 12 8DM 12 Section Double Wall Pipe Snap Lock F0896 18 8DM 18 Section Double Wall Pipe Snap...

Страница 17: ...SQUARE TOP TERMINATION F0922 ETO 8DM Square Top with Mesh MESH SQUARE TOP TERMINATION WITH SLIP SECTION F0923 ETLO 8DM Square Top with Mesh and Slip Section ADJUSTABLE HOOD Required when installing a...

Страница 18: ...8HT 36 Section Hi Temp Double Wall Pipe Snap Lock F0885 48 8HT 48 Section Hi Temp Double Wall Pipe Snap Lock F0886 30E 8HT 30 Degree Hi Temp Offset and Return F0887 12S 8HT Hi Temp Chimney Support For...

Страница 19: ...r propane gas Fuel products with abnormal burning characteristics including but not limited to fuel such as driftwood coal or plywood and wood products using a binder may burn at excessive temperature...

Страница 20: ...ecolors stylesandproducts Consult your local distributor for fireplace code information Printed in U S A 2013 IHP LLC P N 126650 01 Rev B 10 2015 P126650 01 1508 Elm Hill Pike Suite 108 Nashville TN 3...

Отзывы: