background image

Astria.US.com

126650-01B

16

FIREPLACE  ACCESSORIES

CAT NO.

MODEL

DESCRIPTION

REFRACTORY

(Not Shown)

J7006

Refractory, Btm. Center 368ST, 1 Ea.

J7007

Refractory,Btm Front 368ST, 2 Ea.

J7008

Refractory,Rt. Frnt Side 368ST, 4 Ea.

J3941

Refractory, Side (368ST), 2 Ea.

GRATE

J4669

Grate              368ST

SCREEN ASSEMBLY

(Not Shown)

J5668

Screen 19 3/8 X 21

J4956

Nut Push-On.765X.445X.011 Black

J6928

Rod, Screen 36L/R/LS/RS

EMBER PROTECTOR

J6906

Protector, Ember EP 36

INSTALLATION ACCESSORIES

BI-FOLD GLASS DOORS

F1025

DBP368ST

 36" See Thru WB Bi-Fold Door (1 side) - Black Finish

F1026

DC368ST

36" See Thru WB Bi-Fold Door (1 side) - Platinum Finish

J0455

DG368ST

36" See-Thru WB Bi-Fold Door (1 side) - Brushed Finish

DOUBLE WALL PIPE

   

F0895

12-8DM

12" Section Double Wall Pipe Snap Lock

F0896

18-8DM

18" Section Double Wall Pipe Snap Lock

F0897

24-8DM

24" Section Double Wall Pipe Snap Lock

F0898

36-8DM

36" Section Double Wall Pipe Snap Lock

F0899

48-8DM

48" Section Double Wall Pipe Snap Lock

30° OFFSET AND RETURN

F0900

30E-8DM

30 Degree Offset and Return

F0886

30E-8HT

30 Degree Hi-Temp Offset and Return

CHIMNEY SUPPORT

F0902

12S-8DM

Chimney Support (For Use With Chimney Heights In 

Excess of 20')

OPTIONAL OUTSIDE AIR KIT FOR FLOOR INSTALLATION

F1091

AK4

Complete Outside Air Kit w/Collars Hood & 3' Flex

OPTIONAL OUTSIDE AIR KIT FOR SIDEWALL INSTALLATION

F1093

AK4F

Outside Air Kit Collar, Hood & 3' Flex for Floor Venting

Содержание Craftsman STP2

Страница 1: ...r approved to ANS Z21 11 2 standard An INNOVATIVE HEARTH PRODUCTS LLC hood must be installed when using a vent free log heater see Ac cessories page 17 FOR CANADA The authority having jurisdiction suc...

Страница 2: ...hazard The IHP warranty will be voided by and IHP disclaims any respon sibility for the following actions a Modification of the fireplace or any of the components manu factured by IHP unless otherwise...

Страница 3: ...urn veryquickly DONOTusetreatedwood charcoal coal trash driftwoodorwoodsthathavebeendippedintar pitch pine tar creosote etc Wood products made with synthetic binders such as plywood produce ab normall...

Страница 4: ...ce the risk of a chimney fire SAFETY Continued Figure 1 Dimensions WARNING Always leave glass doors fully opened or fully closed when operating fireplace WARNING Children and adults should be alerted...

Страница 5: ...2 Common Location of Fireplace Existing Wall Projected Wall 12 30 4 cm to Perpendicular Wall MINIMUM CLEARANCE TO COMBUSTIBLES Back and sides of fireplace 1 minimum Adjacent wall 12 minimum Chimney ou...

Страница 6: ...From Outer Pipes to Combustibles 1 2 5 cm Min To Combustibles 21 5 16 54 cm 42 5 8 108 cm 24 61 cm 12 31 cm Figure 7 Framing Firebox with Z Type Ember Protectors As Required by Design as Long as Ceil...

Страница 7: ...age 16 Avoid installing outside air eyebrow in areas where inlet opening may be blocked by snow bushes or other obstacles It should also be located beyond the reach of children CAUTION Combustion air...

Страница 8: ...r pipe and a wire spacer Each section of pipe comes in lengths of 12 18 36 and 48 The actual lineal gain for each is measured after each section is fully connected Lineal gain is the actual measurable...

Страница 9: ...e19 Figure 18 Raise and Offset B A Screws Figure 16 Elbow Offset 20 FT 6 096m 20 FT 6 096m Return Elbow 12S 8DM Support Required Figure 17 Chimney Supports 2 5 1cm Minimum Straps 2 5 1cm Minimum Angle...

Страница 10: ...tances such as neighboring hills tall trees or strong wind areas can cause down drafts in chimney system In such cases going beyond the minimum recommended height would be preferable to provide a bett...

Страница 11: ...ed to cover exposed area and flashing base Secure in position by nailing through shingles see Figure 23 DO NOT NAIL THROUGH FLASHING CONE Nail Only Outer Perimeter of Flashing Storm Collar Underlap Sh...

Страница 12: ...al may be used for facing glass tile brick etc as long as proper clearances are adhered to and firebox openings are not obstructed in any way see Figure 27 Use only heat resistant noncombustible morta...

Страница 13: ...s line and refractory knockout hole with refractory cement or commercial furnace cement Install the gas appliance or cap off gas line if desired CAUTION All gas piping and connections must be tested f...

Страница 14: ...e 30 Cabinet Glass Doors Cabinet Glass Doors WARNING FIREPLACESEQUIPPEDWITHDOORS SHOULD BE OPERATED ONLY WITH DOORS FULLY OPENORDOORSFULLYCLOSED IFDOORSARELEFT PARTLYOPEN GASANDFLAMEMAYBEDRAWNOUT OF T...

Страница 15: ...s fireplace OPERATION AND MAINTENANCE GUIDELINES Continued REPLACEMENT PARTS See Page 16 Fireplace Accessories section for replacement parts Use only parts supplied from the manufacturer Normally all...

Страница 16: ...1 side Platinum Finish J0455 DG368ST 36 See Thru WB Bi Fold Door 1 side Brushed Finish DOUBLE WALL PIPE F0895 12 8DM 12 Section Double Wall Pipe Snap Lock F0896 18 8DM 18 Section Double Wall Pipe Snap...

Страница 17: ...SQUARE TOP TERMINATION F0922 ETO 8DM Square Top with Mesh MESH SQUARE TOP TERMINATION WITH SLIP SECTION F0923 ETLO 8DM Square Top with Mesh and Slip Section ADJUSTABLE HOOD Required when installing a...

Страница 18: ...8HT 36 Section Hi Temp Double Wall Pipe Snap Lock F0885 48 8HT 48 Section Hi Temp Double Wall Pipe Snap Lock F0886 30E 8HT 30 Degree Hi Temp Offset and Return F0887 12S 8HT Hi Temp Chimney Support For...

Страница 19: ...r propane gas Fuel products with abnormal burning characteristics including but not limited to fuel such as driftwood coal or plywood and wood products using a binder may burn at excessive temperature...