Astria 126851-01 Скачать руководство пользователя страница 1

Installation and Operation Instructions

Astria™ Unvented (Vent-Free) Gas Heater

P/N 126851-01   Rev. A   02/2014

Remote-Ready Burner System Models

RioLights24MN

RioLights24MP

RioLights30MN

RioLights30MP

P126851-01

INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.

This appliance may be installed in an aftermarket permanently located, manufactured (mobile) home, where not 

prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This 

appliance is not convertible for use with other gases.

WARNING: This appliance is for installation only in a solid-fuel burning masonry or UL127 factory-built 

fireplace or in a listed ventless firebox enclosure. It is design-certified for these installations in accordance 

with ANSI Z21.11.2. Exception: DO NOT install this appliance in a factory-built fireplace that includes 

instructions stating it has not been tested or should not be used with unvented gas logs.

This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is installed. Provisions 

for adequate combustion and ventilation air must be provided. Refer to Air for Combustion and Ventilation 

section on page 6 of this manual.

 

WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result 

causing property damage, personal injury or loss of life.

 

 Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other 

appliance.

 

 WHAT TO DO IF YOU SMELL GAS: 

•   Do not try to light any appliance. 

•   Do not touch any electrical switch; do not use any phone in your building. 

•   Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. 

•  If you cannot reach your gas supplier, call the fire department.

 

Installation and service must be performed by a qualified installer, service agency or the gas supplier.

Содержание 126851-01

Страница 1: ...in a factory built fireplace that includes instructions stating it has not been tested or should not be used with unvented gas logs This is an unvented gas fired heater It uses air oxygen from the roo...

Страница 2: ...only in a solid fuel burning masonry or UL127 factory built fireplace or in a listed ventless firebox enclo sure It is design certified for these installations in accordance with ANSI Z21 11 2 Except...

Страница 3: ...e and proper operation of this fireplace WARNING Any change to this heater or its controls can be dangerous WARNING Do not use a blower insert heat exchanger insertorotheraccessorynotap proved for use...

Страница 4: ...inside fireplace will cause glass to burst Make sure there are no obstructions across openings of fireplace 8 To prevent the creation of soot follow the instructions in Cleaning and Maintenance page...

Страница 5: ...ater assembly from cartons 2 Remove all protective packaging applied to heater for shipment 3 Check heater for any shipping damage If heater is damaged call INNOVATIVE HEARTH PRODUCTS at 1 800 655 200...

Страница 6: ...the warm air in During heating months home owners want their homes as airtight as possible While it is good to make your home energy efficient your home needs to breathe Fresh air must enter your home...

Страница 7: ...nings add the volume of these rooms to the total volume of the space 2 Multiply the space volume by 20 to determine the maximum Btu Hr the space can support _________ volume of space x 20 Maxi mum Btu...

Страница 8: ...re 2 You can also remove door into adjoining room see option 3 Figure 2 Follow the National Fuel Gas Code ANSI Z223 1 NFPA 54 Air for Combustion and Ventilation for required size of ventilation grills...

Страница 9: ...heater in rooms without enough ventilation air may cause mildew to form from too much moisture See Air for Combustion and Ventila tion page 6 NOTICE Thisheater isintended for use as supplemental heat...

Страница 10: ...sted vent free firebox Minimum Clearances For Side Combustible Material Side Wall and Ceiling A Clearances from the side of the fireplace cabinet to any combustible material and wall should follow dia...

Страница 11: ...e material s above the fireplace opening Noncombustible materials such as slate marble tile etc must be at least 1 2 thick With sheet metal you must have noncombustible material be hind it Noncombusti...

Страница 12: ...installation instruc tions for minimum clearances If permitted by the fireplace installation instructions combus tible material may be installed up to the bottom edge of the fireplace face see figure...

Страница 13: ...is could damage heater Only handle base assembly by grates IMPORTANT Make sure the heater burners are level If heater is not level heater will not work properly Installation Items Needed hardware pack...

Страница 14: ...Attaching Base to Fireplace Floor Screws CONNECTING TO GAS SUPPLY WARNING This appliance requires a 1 2 NPT National Pipe Thread inlet connection to the pressure regulator WARNING A qualified ser vic...

Страница 15: ...d matter is not likely to freeze A sediment trap traps moisture and contami nants This keeps them from going into heater controls If sediment trap is not installed or is installed wrong heater may not...

Страница 16: ...s or opening main gas valve located on or near gas meter for natural gas or using compressed air 4 Check all joints of gas supply piping sys tem Apply noncorrosive leak detection fluid to all joints B...

Страница 17: ...heater may result in property damage or personal injury CAUTION Glass pebbles may have sharp edges Wear gloves when handling glass pebbles Clear glass pebbles are included with your fireplace Place gl...

Страница 18: ...actly a fire or explosion may result causing property damage per sonal injury or loss of life A This appliance has a pilot which must be lighted by hand When lighting the pi lot follow these instructi...

Страница 19: ...ual Lighting Procedure 8 Keep control knob pressed in for 30 sec onds after lighting pilot After 30 seconds release control knob If control knob does not pop out when released contact a qualified serv...

Страница 20: ...ve a slight curve but flame should be blue and have no yellow or orange color BURNER FLAME PATTERN Figure 22 shows correct burner flame pattern Figure 23 shows incorrect burner flame pat tern The inco...

Страница 21: ...prior to each heating season Blocked air holes will create soot We recommend that you clean the unit every three months during operation and have heater inspected yearly by a qualified service person...

Страница 22: ...unit off lightly blow air through the air inlet hole You may blow through a drinking straw if compressed air is not available CLEANING AND MAINTENANCE Continued GLASS PEBBLES If you remove glass pebbl...

Страница 23: ...PILOT position 4 Air in gas lines when in stalled 5 Depleted gas supply pro pane LP only 6 ODS pilot is clogged 7 Gas regulator setting is not correct REMEDY 1 Reconnect ignitor cable 2 Free ignitor...

Страница 24: ...ontrol knob pressed in 30 seconds 3 Wait one minute for safety interlock system to reset Repeat ignition operation 4 Fully open equipment shut off valve 5 A Contact local natural or propane LP gas com...

Страница 25: ...et warm up for a minute 2 Operate burner until air is removed from line Have gas line checked by local natural or propane LP gas company 3 Observe minimum installa tion clearances see pages 9 through...

Страница 26: ...Warning statement at top of page 2 Control valve or gas control defective 1 Foreign matter between control valve and burner 2 Gas leak See Warning statement at top of page 1 Optional Hand held remote...

Страница 27: ...only original replacement parts This will protect your warranty coverage for parts replaced under warranty Contact authorized dealers of this product If they can t supply original replacement part s...

Страница 28: ...www Astria US com 126851 01A 28 PARTS REMOTE READY CONTROL MODELS RIOLIGHTS24MN RIOLIGHTS24MP RIOLIGHTS30MN RIOLIGHTS30MP 13 14 12 6 15 16 17 22 1 11 20 19 8 9 18 4 21 3 2 5 5 7...

Страница 29: ...5 01 Ignitor Electronic 1 14 124933 01 Orifice Holder 1 15 099056 38 Injector 111 2 82MM 1 099056 19 Injector 0670 1 70MM 1 16 112829 02 Air Shutter 1 17 119321 01 Tube Venturi 1 18 119975 01 Gasket B...

Страница 30: ...to premium series designs DAMPER CLAMP GA6080 For all models Permanently opens chimney flue damper for vented operation LAVA ROCK GA6060 For all models Order when additional rock is desired SMOOTH GL...

Страница 31: ...se damage to the Product will produce excessive temperatures and could result in a fire hazard c damages caused by failing to provide proper maintenance and service in accordance with the instructions...

Страница 32: ...located on product or identification tag ______________________________ Serial No located on product or identification tag ___________________________ Date Purchased ___________________________ Keep...

Страница 33: ..._____________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ _____...

Страница 34: ..._____________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ _____...

Страница 35: ..._____________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ _____...

Страница 36: ...126851 01 Rev A 02 14 1508 Elm Hill Pike Suite 108 Nashville TN 37210 1 800 655 2008 www IHP US com P126851 01...

Отзывы: