Smoking –  Causes And Troubleshooting

To reduce the likelihood of smoking when opening the door, open 

the combustion air control or damper before opening the door.  

Your appliance has been designed and tested to provide smoke free 

operation. Occasionally, there may be a small amount of smoking 

upon lighting the fire, until the chimney heats up but this should not 

continue.  If the appliance continues to smoke it is probably for one 

of the following reasons:

A. Negative pressure in the house -

  As the fire burns, air goes up the chimney. This air must be 

replaced through leakage into the house or through the outside 

air duct.  When operating the appliance, open a nearby window 

temporarily to check if there is adequate replacement air supply.

B. Blowers operating (e.g.: range hood) - 

These blowers draw air 

out of the house and may actually cause a negative pressure in 

the house.  Turn off all blowers and open a nearby window to 

determine if this is the cause of the problem.

C. Wet wood -

 Wet or tarred wood will smoulder and smoke instead 

of burning properly. Your dealer can help you determine if you 

have properly seasoned wood for burning.

D. Dirty or blocked chimney -

 Check to make sure the chimney is 

clear and clean. If dirty call a certified chimney sweep or use a 

properly sized chimney brush to clean.

E. Chimney not long enough -

 The minimum chimney height is 

twelve (12) feet (3.7 m) not including the appliance height. The 

chimney must extend at least three (3) feet (915 mm) above 

its point of contact with the roof and at least two (2) feet (610 

mm) higher than any roof or wall within ten (10) feet (3 m) of 

it.  When installed with offsets, the minimum chimney height 

is fifteen (15) feet.  Additional height will increase draft and will 

decrease the tendency to smoke.

F.  Poor chimney draft -

 With no fire, there should be sufficient draft 

to exhaust cigarette smoke introduced under the baffle or flue baffle.  

Chimneys installed against an outside wall without protection may 

generate back draft problems which will cause start-up problems.  

To prevent this, open a nearby window, roll up a piece of paper 

and light it.  Then, hold it in the upper part of the firebox to warm 

up the chimney.  Wait until the draft is sufficient, then start the fire.

G. Blower for forced air kit operating (some models)  -

 Make 

sure that the blower is in the “off” position when you open the 

appliance door for reloading.

Locating The Appliance

The best location to install your appliance is determined by consid-

ering the location of windows, doors, and the traffic flow in the room 

where the appliance is located, allowing space in front of the unit for 

the hearth extension and the mantel, and taking into consideration 

the location of the hot air ducts (some models), outside air kit and 

chimney. 

If possible, you should choose a location where the chimney will pass 

through the house without cutting floor or roof joists.
When selecting the location, the chimney outlet position and the 

direction of the wind are important factor affecting the chimney per-

formance. To allow a maximum draft and to reduce wind turbulence, 

the chimney must:

•  Penetrate the highest part of the roof.

•  Be installed as far as possible of roof offsets, trees or any other 

obstructions that may cause wind turbulence and back drafts in 

the chimney.

•  The least amount of offsets (elbows) possible. 

NOTE:

 A maximum 

of 2 offsets is allowed.

4' 

4' 

8' 

Standard 

Cord of

Wood

8 Ft. 

(2.4M)

4 Ft. 

(1.2M)

4 Ft. (1.2M)

Marginal Location

Wind Direction

Location

Not

Recommended

Outside Air 

Intake

Facing the Wind

Location

Not 

Recommended

Location Recommended

Tree

Figure 1

Figure 2

Prohibited Fuels

These appliances are designed to burn natural well-seasoned wood. 

The wood fuel should be air dried seasoned hardwoods, as compared 

to softwoods or to green or freshly cut hardwoods. Burning artificial 

logs, in some model appliances is allowed (see Installation and Op-

eration manual); please read and follow the instructions provided by 

the manufacturer. DO NOT BURN:

NOTE: The use of a firewood moisture meter is recommended 

to ensure the firewood contains less than 20% moisture.

Seasoning Guide

Softwoods  -  6 months to 18 months

Hardwoods  -  12 months to 24 months
Logs that are 5” diameter across or larger should be split in half, 

three pieces if over 8 inches, and four pieces when over a foot 

across. If a tree has been dead for 2  -  4 years it still needs to be 

cut, split, and seasoned for 6 to 24 months depending on the wood.

• Garbage;

•  Lawn clippings or yard waste;

•  Materials containing rubber, 

including tires;

•  Materials containing plastic;

•  Waste petroleum products, 

paints or paint thinners, or 

asphalt products;

•  Materials containing asbestos;

•  Construction or demolition 

debris;

•  Railroad ties or pres-

sure-treated wood; woods that 

have been dipped in tar, pitch, 

pine tar, creosote, etc.

• Manure or animal remains;

• Salt water driftwood or 

other previously salt water 

saturated materials;

• Unseasoned wood;

• Christmas tree branches;

• Paper products, colored 

paper, cardboard, plywood, 

or particleboard; 

• Gasoline;

• Naphtha;

• Engine Oil; 

• Flammable Liquids; 

• Solvents;

• Grease; or

• Charcoal or Coal

Содержание Tuscan36P2

Страница 1: ...DA The authority having jurisdiction such as the municipal building department fire department etc should be contacted before installation to determine the need to obtain a permit POUR LE CANADA L autorité compétente comme le service municipal du bâtiment les pompiers etc doit être contacté avant l installation afin de déterminer la nécessité d obtenir un permis This appliance may be installed in ...

Страница 2: ...allation 12 Operation and Maintenance Guidelines 13 Technical Service 14 Replacement Parts 14 Important Notices Canada 15 Parts 16 Accessories 18 Draft Smoke Guidelines Appendix A 21 Warranty 23 Thank you for your purchase We appreciate your business Please carefully read and follow all instructions in this manual Pay special attention to all warnings and safety information Following these safety ...

Страница 3: ...seasignificanthazard IMPORTANT See appendix A page 21 for additional information regarding draft requirements smoking causes and troubleshooting WARNING BURNINGIMPROPERFUEL I E CHAR COAL CAN RESULT IN CARBON MONOXIDE POISON ING WHICH MAY LEAD TO DEATH Carbon Monoxide Poisoning Early signs of carbon monoxidepoisoningresemblethefluwithheadaches dizziness or nausea If you have these signs get fresh a...

Страница 4: ...29 737 mm 41 1042 mm 1 26 mm 1 26 mm 21 534 mm 8 204 mm 35 889 mm 37 940 mm 41 1042 mm 1 26 mm AIRSPACE TO COMBUSTIBLE MATERIAL 0 0 mm TO TOP SPACERS 0 0 mm TO BOTTOM 8 204 mm EACH SIDE NO COMBUSTIBLE MATERIAL ON FACE HEARTH EXTENSION 51 X 16 1296 mm X 407 mm COMBUSTIBLE WALL BOARD NOT LESS THAN 12 305 mm TO PERPENDICULAR SIDEWALL OUTSIDE AIR LEFT SIDE ONLY ROUND TOP TERMINATION SQUARE CHASE TOP T...

Страница 5: ...it is available with this fireplace see Optional Outside Air Kit on page 7 MINIMUM CLEARANCE TO COMBUSTIBLES Ceiling 40 1016 mm minimum Back and sides of fireplace 3 4 19 mm minimum Floor 0 0 mm minimum Perpendicular wall to opening 12 305 mm minimum Top spacers 0 0 mm minimum Mantel clearances see Mantels page 6 Chimney outer pipe surface 1 26 mm minimum Not required at nailing flanges See step 2...

Страница 6: ...rete metal glass marble stone etc Provide a means to prevent the hearth extension from shifting and seal gap between the fireplace frame and hearth extension with a noncom bustible material see Figure 3 WARNING Hearth extension is to be installed only as shown in Figure 3 Figure 3 Hearth Extension Seal Gap Fireplace Front Ember Protector Fireplace Front Raised Hearth Fireplace Front Elevated Ember...

Страница 7: ...ty to individual site requirements Actual lengths gained after fitting overlaps must be taken into consideration lineal gain and are given in the lineal gain chart see Figure 6 Lineal gain is the actual measurable length of a part after two or more parts are connected For Canada use chimney parts designated HT ASSEMBLY AND INSTALLATION OF DOUBLE WALL CHIMNEY SYSTEM Each double wall chimney section...

Страница 8: ...ove offset rests on return elbow Straps must be securely nailed to rafters or joists see Figure 8 details A and B 3 Maximum length of pipe between supports return elbow or 12S 8DM is 6 of angle run Maximum of two 6 angle run sections per chimney system see Figure 7 4 All pipe connections between offset and return must be secured with two screws on outer pipe only see Figure 9 page 9 Do not penetra...

Страница 9: ...showninFigure10 They also provide complete separation from one floor space to another or attic space as required by most codes When the double wall pipe passes through a framed opening into an attic space the firestop must be placed into an attic floor as shown in Figure 11 NOTICE The installation of a firestop thimble FST30 or 38FST is recommended when negotiating a joist and to prevent intrusion...

Страница 10: ...ingles as needed to cover exposed area and flashing base Secure in position by nailing through shingles see Figure 13 DO NOT NAIL THROUGH FLASHING CONE Installing Flashing on a Metal Roof When installing flashing on a metal roof it is required that putty tape be used between the flashing and roof The flashing must be secured to the roof using 8 x 3 4 screws and then sealed with roof coating to pre...

Страница 11: ...at is within a horizontal distance of 10 feet see Figure 17 FINISHING FIREPLACE Combustible materials such as wallboard sheet rock drywall ply wood etc may make direct contact with sides and top around the fireplace face It is important that combustible materials do not overlap the face itself Brick glass tile or other noncombustible materials may overlap the front face provided they do not obstru...

Страница 12: ...nections must be tested for leaks after the installation is completed After ensuring that the gas valve is on apply soap and water solution to all connections and joints Bubbles formingshowaleak Correctallleaksatonce DONOT USEANOPENFLAMEFORLEAKTESTINGANDDONOT OPERATE ANY APPLIANCE IF A LEAK IS DETECTED LEAK TESTING SHOULD BE DONE BY A QUALIFIED SERVICE PERSON Note An IHP hood must be installed whe...

Страница 13: ...he appliance imme diately if doors are damaged and contact a qualified installer for repair Only doors certified with the ap pliance shall be used WARNING Do not slam or strike doors Damage can result in a hazardous condition Cleaning Glass Clean the glass with any commercial glass cleaner or soap and water Do not use any abrasive material to clean the glass Do not clean the glass with any cool wa...

Страница 14: ...rdered through your IHP distributor or dealer Parts will be shipped at prevailing prices at time of order When ordering repair parts always give the following information 1 The model number of the fireplace 2 The serial number of the fireplace 3 The part number 4 The description of the part 5 The quantity required 6 The installation date of the fireplace If you encounter any problems or have any q...

Страница 15: ...ipe Snap Lock F0884 36 8HT 36 Section Hi Temp Double Wall Pipe Snap Lock F0885 48 8HT 48 Section Hi Temp Double Wall Pipe Snap Lock F0886 30E 8HT 30 Degree Hi Temp Offset and Return F0887 12S 8HT Hi Temp Chimney Support For Use With Chimney Heights In Excess of 30 F0888 RT 8HT Hi Temp Round Top with Mesh Screen F0889 RTT 8HT Hi Temp Round Top with Mesh Screen and Slip Sec tion F0890 RLT 8HT Hi Tem...

Страница 16: ...Astria us com 126764 01_F 16 PARTS 9 24 16 31 25 16 4 30 32 19 12 23 20 28 17 8 1 5 21 2 18 11 14 3 13 22 10 6 29 7 33 34 26 27 15 MODEL CATALOG NO TuscanP2 F0540 TuscanP3 F0541 ...

Страница 17: ...mper Can Collar 1 16 J8012 Kit Screen Assembly 1 17 Firebox Top Assembly 1 18 J3980 Air Kit Door Assembly 1 19 Face Weldment 1 20 J4470 Air Deflector 1 21 Fireplace Top Insulation 1 22 J4052 Access Panel 1 23 J4491 Grate 1 24 Collar Insulation 1 25 J6893 Chimney Starter Collar 1 26 J6895 Refractory Retainer 2 27 J3939 Grate Retainer 2 28 J4504 Door Stop 1 29 J4523 Pivot Clip 2 30 J6905 Spring Clip...

Страница 18: ...White S36 1 4 Refractory Rear Her White S36 1 5 Refractory Btm Rear White S36 1 6 Refractory Btm Frnt White S36 1 1 2 4 3 6 5 Stacked Refractory Shown ACCESSORIES REFRACTORY STAIN KITS Use the refractory stain kits to give white refractory panels a new look Kit includes foam roller handle paint tray and one can of stain Available stain colors are creamer ivory Rust terra cotta and Cappuccino rosy ...

Страница 19: ...n Hi Temp Double Wall Pipe Snap Lock F0882 18 8HT 18 Section Hi Temp Double Wall Pipe Snap Lock F0883 24 8HT 24 Section Hi Temp Double Wall Pipe Snap Lock F0884 36 8HT 36 Section Hi Temp Double Wall Pipe Snap Lock F0885 48 8HT 48 Section Hi Temp Double Wall Pipe Snap Lock 30 OFFSET AND RETURN F0900 30E 8DM 30 Degree Offset and Return OPTIONAL OUTSIDE AIR KIT FOR FLOOR INSTALLATION F1091 AK4 Comple...

Страница 20: ...1 ETL 8DM Square Top with Slip Section F0893 ETL 8HT Hi Temp Large Pyramid Top with Slip Section MESH SQUARE TOP TERMINATION F0922 ETO 8DM Square Top with Mesh MESH SQUARE TOP TERMINATION WITH SLIP SECTION F0923 ETLO 8DM Square Top with Mesh and Slip Section STAINLESS STEEL HOOD Required when installing a vent free gas log in this fireplace F1052 HS36 36 Stainless Steel Hood w 4 Brow DRAIN PAN F10...

Страница 21: ...ons inadequate chimney heights adversewindconditionsand orunusualenvironmental factors or conditions beyond our control take into account all variables within the installation and install the appliance in such a manner that satisfies the draft requirements of the appliance See Chimney Guidelines to assist you in selecting the proper venting system for your installation American National Standards ...

Страница 22: ...The best location to install your appliance is determined by consid ering the location of windows doors and the traffic flow in the room where the appliance is located allowing space in front of the unit for the hearth extension and the mantel and taking into consideration the location of the hot air ducts some models outside air kit and chimney Ifpossible youshouldchoosealocationwherethechimneywi...

Страница 23: ...or propane gas Fuel products with abnormal burning characteristics including but not limited to fuel such as driftwood coal or plywood and wood products using a binder may burn at excessive temperatures and may cause damage to the Product or may cause it to function improperly c damages caused by failing to provide proper maintenance and service in accordance with the instructions provided with th...

Страница 24: ...01 Innovative Hearth Products reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your local distributor for fireplace code information Printed in U S A 2014 Innovative Hearth Products LLC P N 126764 01 Rev F 01 2019 1769 East Lawrence Street Russellville AL 35654 ...

Отзывы: