Astria Fireplaces Mission36TMN Скачать руководство пользователя страница 1

Installation and Operation Instructions

Astria

TM

 Mission B-Vent Fireplace

Millivolt System

P/N 126753-01   Rev. B        03/2014.

Models
Mission36TMN

Mission42TMN

P126753-01

INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.

Installateur : Laissez cette notice avec l’appareil.
Consommateur : Conservez cette notice pour consultation ultérieure.

This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or mobile 

home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the 

rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.

WARNING AVERTISSEMENT AVISO

HOT GLASS

 WILL 

CAUSE BURNS.

DO NOT TOUCH

 GLASS 

UNTIL COOLED.

NEVER ALLOW

 CHILDREN 

TO TOUCH GLASS.

UNE SURFACE VITRÉE CHAUDE

 PEUT 

CAUSER DES BRÛLURES.

LAISSER REFROIDIR

 LA SURFACE VITRÉE 

AVANT D’Y TOUCHER.

NE PERMETTEZ JAMAIS

 À UN ENFANT DE 

TOUCHER LA SURFACE VITRÉE.

EL VIDRIO CALIENTE 

CAUSARÁ QUEMADURAS.

USTED DEBE 

NUNCA TOCAR 

EL VIDRIO CALIENTE.

LOS NIÑOS DEBEN 

NUNCA 

TOCAR EL VIDRIO.

WARNING: If the information in these 

instructions is not followed exactly, a fire or 

explosion may result causing property damage, 

personal injury or death.

AVERTISSEMENT : Assurez-vous de bien suivre les 

instructions données dans cette notice pour réduire au 

minimum le risque d’incindie ou d’explosion ou pour éviter 

tout dommage matériel, toute blessure ou la mort.

 

 Do not store or use gasoline or other 

flammable vapors and liquids in the vicinity 

of this or any other appliance.

 

 WHAT TO DO IF YOU SMELL GAS: 

• 

 Do not try to light any appliance. 

• 

 Do not touch any electrical switch; do not 

use any phone in your building. 

• 

 Immediately call your gas supplier from 

a neighbor’s phone. Follow the gas 

supplier’s instructions. 

• 

If you cannot reach your gas supplier, call 

the fire department.

 

Installation and service must be performed 

by a qualified installer, service agency or the 

gas supplier.

 

 Ne pas entreposer ni utilizer d’essence ni d’autres 

vapeurs  ou liquides inflammables dans le voisinage 

de cet appareil ou de tout autre appareil.

 

 QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ : 

• 

 Ne pas tenter d’allumer d’appareil.

• 

Ne touchez à aucan interrupteur. Ne pas vous 

servir des téléphones se trouvant dans le bâtiment 

où vous trouvez.

• 

Appelez immédiatement votre fournisseur de 

gaz depuis un voisin. Suivez les instructions du 

fournisseur.

• 

Si vous ne pouvez rejoindre le fournisseur de gaz, 

appelez le service des incindies.

 

L’installation et l’entretien doivent être assurés par un 

installateur ou un service d’entretien qualifié ou par le 

fournisseur de gaz.

PFS

®

US

C

f i r e - p a r t s . c o m

Содержание Mission36TMN

Страница 1: ...e personal injury or death AVERTISSEMENT Assurez vous de bien suivre les instructions donn es dans cette notice pour r duire au minimum le risque d incindie ou d explosion ou pour viter tout dommage m...

Страница 2: ...ain your appliance it also con tains information that will enable you to obtain replace ment parts or optional accessory items when needed Keep it with your other important papers This fireplace may n...

Страница 3: ...t from carpeting bedding material etc Turn off the gas valve and pilot light before cleaning fireplace 10 Have venting system inspected annually by a qualified service person If needed have venting sy...

Страница 4: ...ollowing items are packed inside the firebox Remove before positioning firebox into framing Transition Collar For vent connection Ceramic Log Pack Shrink wrapped on cardboard Three 3 plastic bags cont...

Страница 5: ...nections to the appliance This fireplace must be installed in an unconfined space with a minimum of 50 cubic feet per 1 000 BTUs of gas output Therefore 36 models require 2 650 cubic feet 42 models re...

Страница 6: ...23 kPa 13 WC 3 23 kPa Orifice Size 52 51 S T P Q R X Outside Air Kit Location Optional K 7 J I M L V 13 5 1 5 Glass Door Optional W O N Alternate Gas Supply Inlet 7 G H F A Stand Off Collar For Use Wi...

Страница 7: ...tle components in relation to fireplace opening Spacer 3 7 6 cm 1 1 2 3 8 cm Max B 6 15 2 cm A 12 22 9 cm Combustible Materials Header Figure 5 Mantel Clearances Side View Cross Section MISSION36TMN F...

Страница 8: ...face provided thatanygapisbetweenthemate rial used and the face is caulked withanoncombustiblecaulking Figure 7 Rough Opening for Installing in Wall B C A MISSION36TMN F0857 F0859 AND F0861 MISSION42...

Страница 9: ...in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than 1 2 in size GAS VENT DIRECTLY BELOW KEEP CLE...

Страница 10: ...connected to the appliance for venting to the outside of the building INNOVATIVE HEARTH PRODUCTS defines the installation standards of its product Third party products must be installed to their speci...

Страница 11: ...aping of spillage of burned gas is indicated when the match flickers or goes out Smoke from a cigarette will also tend to disperse away from the appliance If appliance is found to be improperly vent i...

Страница 12: ...not wire re mote wall switch to main power supply Standard 120v house hold current 3 Locate wall switch in a convenient location 4 After wire connections are complete replace refractory access panel...

Страница 13: ...o inside of appliance a sediment trap must be included outside appliance between gas line and gas shutoff valve It must extend down 3 beyond center of pipe Prepare incoming black iron gas line with te...

Страница 14: ...onotuseanopenflameforleak testing and do not operate any appliance if a leak is detected INSTALLATION Continued Complete your gas installation by connect ing incoming gas line with flexible gas line S...

Страница 15: ...to notch on left of log 2 see Figure 24 Rest lower end of log 5 on grate as shown in Figure 25 6 Insert lower end of log 6 between first two grate fingers as shown in Figure 25 and position upper end...

Страница 16: ...er end of log 5 into notch on top inner right of log 1 see Figure 28 Rest lower end of log 5 on middle grate finger as shown in Figure 29 6 Place log 6 into notch on top right of log 1 see Figure 28 R...

Страница 17: ...re 31 Sealing Between Appliance and Framing INSTALLING OPTIONAL GLASS DOOR ACCESSORY CAUTION Use only glass doors certified for use with this appliance Note Glass door may be heavy for some individual...

Страница 18: ...rame rail see Figure 34 CAUTION Always operate the appliance with the doors ei ther fully opened or fully closed Operating the appliance with the doors partially open can re sult in improper venting o...

Страница 19: ...e 36 Control Knob in the PILOT position Position Indicator Gas Control Knob Pilot Adjustment Screw FOR YOUR SAFETY READ BEFORE LIGHTING WARNING If you do not fol low these instructions exactly a fire...

Страница 20: ...e see Troubleshooting page 23 Thermopile Pilot Burner Ignitor Figure 38 Correct Pilot Flame Pattern Figure 39 Typical Flame Pattern OPTIONAL HAND HELD REMOTE OPERATION Note The receiver and hand held...

Страница 21: ...foreservicing appliance WARNING Failure to keep the primary air opening s of theburner s cleanmayresultin sooting and property damage PILOT AND BURNER Remove logs and ember material before cleaning bu...

Страница 22: ...parts This will protect your warranty coverage for parts replaced under warranty PARTS UNDER WARRANTY Contact authorized dealers of this product If they can t supply original replacement part s call...

Страница 23: ...es defective or too long 2 Thermopile not generating sufficient voltage 1 Pilot flame may be too low causing safety pilot to drop out 2 Improper venting or exces sive blockage REMEDY 1 Check to see if...

Страница 24: ...spark and electrode wire is properly connected replace ignitor 2 Using a match light pilot If pilot lights turn off pilot and trigger the red button again If pilot lights an improper gas air mixture c...

Страница 25: ...low fuel supply 3 Gas leak See Warning statement at top of page 1 Gas leak See Warning statement at top of page 2 Control valve defective 1 Foreign matter between control valve and burner 2 Gas leak S...

Страница 26: ...ON36TMN F0857 F0859 AND F0861 AND MISSION42TMN F0863 F0865 AND F0867 43 21 1 10 11 6 8 8 22 23 Back 25 13 4 14 45 17 3 44 40 39 41 42 9 9 7 46 19 47 7 47 20 5 16 12 15 25 33 31 28 32 27 11 24 18 38 37...

Страница 27: ...mbly 1 23 20042 20042 Air Kit Cover 1 24 106948 02 107823 02 Smoke Deflector 1 25 20027 20027 Brick Liner Retainer 2 26 107796 01 107796 02 Grate Assembly 1 27 107742 01 107742 02 Burner Pan 1 28 1077...

Страница 28: ...ry Std Brick F0859 F0861 F0865 and F0867 1 108165 01 108170 01 Right Refractory Herringbone F0859 F0861 F0865 and F0867 1 14 106660 01 107816 01 Rear Refractory Std Brick F0859 F0861 F0865 and F0867 1...

Страница 29: ...KEY NO PART NUMBER DESCRIPTION QTY 107999 01 Log Set 1 108724 01 Right Front 9 Split Log 1 2 901098 01 Rear Log 1 3 108720 01 Top Right Log 11 3 4 1 4 108721 01 Top Right Log 16 1 5 108722 01 Top Lef...

Страница 30: ...2B 108839 01 Right Front Log 15 3 4 Round 1 3 108722 01 Top Left Log 13 1 2 Y Log 1 4 108838 01 Inside Top Left Log 15 3 4 Split 1 5 108721 01 Inside Top Right Log 16 1 6 108720 01 Top Right Log 11 3...

Страница 31: ...Finish BD42B 42 Brushed Brass Finish BD42P 42 Platinum Finish FIXED GLASS DOORS FD36 36 Black Finish FD36B 36 Brushed Brass Finish FD36P 36 Platinum Finish FD42 42 Black Finish FD42B 42 Brushed Brass...

Страница 32: ...______________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ____________...

Страница 33: ...______________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ____________...

Страница 34: ...r acts of God b damages caused by abuse negligence misuse or unauthorized alteration or repair of the Product affecting its stability or performance The Product must be subjected to normal use The Pro...

Страница 35: ...odel located on product or identification tag ______________________________ Serial No located on product or identification tag ___________________________ Date Purchased ___________________________ K...

Страница 36: ...materials specifications pricesandalsotodiscontinuecolors stylesandproducts Consult your local distributor for fireplace code information Printed in U S A 2013 IHP LLC P N 126753 01 Rev B 03 2014 1508...

Отзывы: