Astria Fireplaces Inglenook CLP2 Скачать руководство пользователя страница 1

Astria® Multi-Sided

Wood burning Fireplaces

MODELS

INSTALLATION AND OPERATION 

INSTRUCTIONS

P/N 126647-01 Rev.  E  02/2018

REPORT NO. 09-146

P126647 01

Inglenook CRP2

Inglenook CLP2

PFS

®

US

C

SAVE THIS BOOK

This book is valuable. In addition to instructing you on how to install and maintain your appliance, it also 

contains information that will enable you to obtain replacement parts or accessory items when needed. Keep 

it with your other important papers.

INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.

Installateur : Laissez cette notice avec l’appareil.
Consommateur : Conservez cette notice pour consultation ultérieure.

This wood burning fireplace complies with UL127 

CAN/ULC-S610-M87 standard as a FACTORY 

BUILT FIREPLACE.

Ce foyer au bois est conforme aux UL 127 CAN/ULC-

S610-M87 norme comme une USINE CONSTRUITE 

CHEMINÉE.

This fireplace is approved for use as a wood burning fireplace or for use with a vented gas log approved to 

ANS Z21.60, Z21.84 standards or for use with a vent-free gas log heater approved to ANS Z21.11.2 standard. 

An INNOVATIVE HEARTH PRODUCTS, LLC hood must be installed when using a vent-free log heater (see Ac-

cessories, page 17). 
FOR CANADA: The authority having jurisdiction 

(such as the municipal building department, fire 

department, etc.) should be contacted before 

installation to determine the need to obtain a permit.

POUR LE CANADA: L’autorité compétente (comme le 

service municipal du bâtiment, les pompiers, etc.) doit 

être contacté avant l’installation afin de déterminer la 

nécessité d’obtenir un permis.

This installation manual will enable you to obtain a safe, efficient and dependable installation of your fireplace 

system. Please read and understand these instructions before beginning your installation.

Do not alter or modify the fireplace or its components under any circumstances. Any modification or alteration of 

the fireplace system, including but not limited to the fireplace, chimney components and accessories, may void the 

warranty, listings and approvals of this system and could result in an unsafe and potentially dangerous installation.

IMPORTANT! TO ASSURE PROPER ALIGNMENT OF GLASS DOORS: INSTALL THIS FIREPLACE IN A SQUARE 

AND PLUMB CONDITION, USING SHIMS AS NECESSARY AT SIDES AND/OR BOTTOM.

Ce manuel est disponible en francais, simplement  

en faire la demande. Numéro de la pièce 126647-02.

NOTE: DIAGRAMS AND ILLUSTRATIONS THROUGHOUT THE MANUAL ARE NOT TO SCALE.

Содержание Inglenook CLP2

Страница 1: ...st be installed when using a vent free log heater see Ac cessories page 17 FOR CANADA The authority having jurisdiction such as the municipal building department fire department etc should be contacted before installation to determine the need to obtain a permit POUR LE CANADA L autorité compétente comme le service municipal du bâtiment les pompiers etc doit être contacté avant l installation afin...

Страница 2: ...h have been designed and tested for the fireplace system you may cause a fire hazard The IHP warranty will be voided by and IHP disclaims any respon sibility for the following actions a Modification of the fireplace components doors air inlet system and damper control b Use of any component part not manufactured or approved by IHP in combination with an IHP fireplace system Proper installation is ...

Страница 3: ...seasignificanthazard IMPORTANT See appendix A page 19 for additional information regarding draft requirements smoking causes and troubleshooting WARNING BURNING IMPROPER FUEL I E CHARCOAL CAN RESULT IN CARBON MONOXIDE POISONING WHICH MAY LEAD TO DEATH Carbon Monoxide Poisoning Early signs of carbon monoxidepoisoningresemblethefluwithheadaches dizziness or nausea If you have these signs get fresh a...

Страница 4: ...or clothing ignition Young children should be carefully supervised when in the same room as fireplace SAFETY Continued Figure 1 Dimensions MODEL CATALOG NO Inglenook CRP2 F0698 Inglenook CLP2 F0699 Inglenook CRP2 F0700 Inglenook CLP2 F0701 31 788 mm 39 1 8 994 mm 13 331 mm 22 559 mm 18 7 8 480 mm 22 3 4 578 mm 7 178 mm 8 204 mm 20 508 mm 20 508 mm 12 305 mm 10 1 2 667 mm 16 1 4 413 mm 8 3 4 223 mm...

Страница 5: ...NG DO NOT PACK REQUIRED AIR SPACES WITH INSULATION OR OTHER MATERIALS Do not obstruct fireplace openings ie louvers etc with any type of facing material Combustible mate rial must not be in contact with back of front face of fireplace FRAMING 1 Frame opening for fireplace using dimensions shown in Figures 2 and 3 2 If fireplace is to be installed directly on carpeting tile or any combustible mater...

Страница 6: ...stone etc Provide a means to prevent hearth extension from shifting and seal gap between fireplace frame and hearth extension with a non combustible material such as sand cement grout see Figure 3 page 5 WARNING Hearth extension is to be installed only as shown in Figure 5 MANTEL CLEARANCES Woodwork such as wood trims mantels or any other combustible material must not be placed at least 9 above op...

Страница 7: ...e preferable to provide a better draw Maximum height approved for any chimney run with this fireplace system is 60 feet as measured from fireplace bottom to flue outlet end of termination Double Wall Chimney System An IHP chimney system consists of 12 18 24 36 and 48 snap lock double wall pipe segments planned for maximum adaptability to individual site requirements Actual lengths gained after fit...

Страница 8: ... 34 5 8 48 8DM Pipe Section 46 5 8 RT 8DM Round Termination 6 7 8 RTL 8DM Round Termination 7 3 4 RTT 8DM Round Termination with Slip Section 6 7 8 to 23 1 8 RTTL 8DM Round Termination with Slip Section 7 3 4 to 21 1 2 ET 8DM Square Chase Termination 12 ETL 8DM Square Chase with Slip Section 7 to 15 ETO 8DM Square Chase with Mesh 12 ETLO 8DM Square Chase with Mesh and Slip Section 12 to 21 1 2 Lin...

Страница 9: ... ceiling into an attic a firestop thimble 38FST or FST30 is required to avoid intrusion by insulation and recommended to negotiate a joist see Figure 15a page 10 Figure 12 Typical Offset Installations Figure 13 Chimney Supports Return Elbow Return Elbow Return Elbow Return Elbow Return Elbow Offset Elbow Offset Elbow Offset Elbow Offset Elbow 6 1 88 m Max 6 1 88 m Max 6 1 88 m Max 6 1 88 m Max 6 1...

Страница 10: ...et must be supported Figure 16 Support Sections 20 FT 6 10 m 20 FT 6 10 m 12S 8DM Support Return Elbow Effective Height of Termination Cap Effective Height of Termination Cap Effective Height of Termination Cap RT 8DM RT 8DM RT 8DM 14 4 27 m Min Height Standard Installation Alternate Installation 15 4 57 m Min Height 2 61 m Max Pipe Length 30E 8DM Maximum Height 60 18 29 m Figure 17 Typical Instal...

Страница 11: ...h roof opening chart Slide flashing over pipe until base is flat against roof Replace as many shingles as needed to cover exposed area and flashing base Secure in position by nailing through shingles see Figure 19 DO NOT NAIL THROUGH FLASHING CONE Installing Flashing on a Metal Roof When installing flashing on a metal roof it is required that putty tape be used between flashing and roof Flashing m...

Страница 12: ...3 above the highest point where it passes through the roof and must be at least 2 above roof with a 10 horizontal span see Figure 23 FINISHING FIREPLACE Combustible materials such as wallboard sheet rock drywall ply wood etc may directly contact sides and top front edge at nailing flanges of fireplace face It is important that combustible materials do not overlap the face itself Brick glass tile o...

Страница 13: ...ne and refractory knockout hole with refractory cement or commercial furnace cement Install the gas appliance or cap off gas line if desired CAUTION All gas piping and connections must be tested for leaks after installation is completed After ensuring that gas valve is on apply soap and water solutiontoallconnectionsandjoints Bubblesforming show a leak Correct all leaks at once DO NOT USE AN OPEN ...

Страница 14: ...replace system in a cold climate area Following these steps will aid in reducing cold air infiltration from fireplace enclosure into living space 1 Fireplace must be placed on a solid continuous surface Add insulation under fireplace in all cold climate areas 2 Insulate under raised platform or cantilevered chase to reduce air infiltration 3 Insulate walls of chase both outer and interior partitio...

Страница 15: ...ous condition OPERATION AND MAINTENANCE GUIDELINES Continued Cleaning Glass Clean glass with any commercial glass cleaner or soap and water Do not use any abrasive material to clean glass Do not clean glass with any cool water if glass is still hot from the fire To remove doors refer to instructions included with glass door kit GRATE The grate is designed to provide you with the maximum solid fuel...

Страница 16: ...d Glass Door Brushed F1024 DC36L R LS RS Glass Door Platinum DOUBLE WALL PIPE F0895 12 8DM 12 Section Double Wall Pipe Snap Lock F0896 18 8DM 18 Section Double Wall Pipe Snap Lock F0897 24 8DM 24 Section Double Wall Pipe Snap Lock F0898 36 8DM 36 Section Double Wall Pipe Snap Lock F0899 48 8DM 48 Section Double Wall Pipe Snap Lock 30 OFFSET AND RETURN F0900 30E 8DM 30 Degree Offset and Return F088...

Страница 17: ...ETL 8HT Hi Temp Large Pyramid Top with Slip Section MESH SQUARE TOP TERMINATION F0922 ETO 8DM Square Top with Mesh MESH SQUARE TOP TERMINATION WITH SLIP SECTION F0923 ETLO 8DM Square Top with Mesh and Slip Section ADJUSTABLE HOOD Required when installing a vent free gas log in this fireplace F1764 GA6050 Black Fireplace Hood FAN KIT F1087 VCBK4R 2 Fan Kit Corners Only F1088 VCBK4L 2 Fan Kit Corner...

Страница 18: ...6 8HT 36 Section Hi Temp Double Wall Pipe Snap Lock F0885 48 8HT 48 Section Hi Temp Double Wall Pipe Snap Lock F0886 30E 8HT 30 Degree Hi Temp Offset and Return F0887 12S 8HT Hi Temp Chimney Support For Use With Chimney Heights In Excess of 30 F0888 RT 8HT Hi Temp Round Top with Mesh Screen F0889 RTT 8HT Hi Temp Round Top with Mesh Screen and Slip Sec tion F0890 RLT 8HT Hi Temp Round Top with Louv...

Страница 19: ...ing the proper venting system for your installation American National Standards Institute ANSI NFPA 211 Standard for Chimneys Fireplaces Vents and Solid Fuel Burning Appli ances See Draft Section A chimney or vent shall be so designed and constructed to develop a flow sufficient to completely remove all flue and vent gases to the outside atmosphere The venting system shall satisfy the draft requir...

Страница 20: ...est location to install your appliance is determined by consid ering the location of windows doors and the traffic flow in the room where the appliance is located allowing space in front of the unit for the hearth extension and the mantel and taking into consideration the location of the hot air ducts some models outside air kit and chimney Ifpossible youshouldchoosealocationwherethechimneywillpas...

Страница 21: ..._____________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ________________________________________...

Страница 22: ..._____________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ________________________________________...

Страница 23: ...or propane gas Fuel products with abnormal burning characteristics including but not limited to fuel such as driftwood coal or plywood and wood products using a binder may burn at excessive temperatures and may cause damage to the Product or may cause it to function improperly c damages caused by failing to provide proper maintenance and service in accordance with the instructions provided with th...

Страница 24: ...01 Innovative Hearth Products reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your local distributor for fireplace code information Printed in U S A 2013 Innovative Hearth Products LLC P N 126647 01 Rev E 02 2018 1769 East Lawrence Street Russellville AL 35654 ...