MAINTENANCE GUIDE/WARNINGS
1- PH & ORP SENSORS
1- Cleaning (electrode bulb clogged or covered in scales).
o
Wet the sensor in a hydrochloric acid solution diluted to 10%, or a cleaning solution provided by a
professional for ten minutes.
o
Rinse well with clean water.
o
Calibrate the sensor once again.
Warning:
Always clean the sensor before calibrating it.
Warning:
In order to clean the sensor, avoid using abrasive materials that might scratch the electrode bulb.
Warning:
NEVER WIPE THE SENSOR WITH A CLOTH OR RAG, but instead drain off any excess by shaking it softly.
2- Winter shutdown
Dismantle the pH/RX sensor and put back in place the original cover it was provided with, after necessarily filling it
with a potassium chloride solution (KCl) in order to wet the sensor membrane.
Warning: Store the sensors in a dry location at a constant temperature. Never leave the sensors out in the open air
or exposed to frost.
2- ELECTRODE
1- Electrode handling
If the electrode's removal/insertion is difficult, heavily grease the toric joint (O-ring) of the
electrode, as well as the vessel, using silicone grease each time it is handled.
2- Cleaning - scale removal
If the electrode plates have limescale deposits on them, then they must be cleaned by soaking
them for several hours in a solution containing 80% water and 20% hydrochloric acid.
Warning: ALWAYS POUR ACID INTO WATER AND NEVER THE OTHER WAY AROUND. WEAR PROPERLY ADAPTED
PROTECTIVE GEAR.
Warning
:
Upon soaking the electrode in order to remove limescale deposits, do not submerge it beyond the toric
joint (O-ring).
Then check the reasons for the limescale build-up.
salt level too low
polarity inversion duration too long
electrode reaching end of life span
pH too high
failure in case's polarity inversion
If the pool filtering continues throughout the winter months, the chlorinator's operation will stop at any
temperature below 5°C. In such an instance, remove the electrode from the vessel and, after cleaning it, store it in a
dry place protected from frost.
3- VESSEL
If there is a risk of frost/freezing, flush the vessel out using the flushing plug located beneath the vessel.