background image

19

Astra P-7 USER MANUAL

The Idle display mode has the following options:

The display stays in the last selected menu section. In case the menu has been in the edit mode, the changes are 

discarded and the edit mode is exited.
The display exits the last selected menu section and cycles between a current room temperature and a clock. 

<-> 

The display exits the last selected menu section and moves to the Temperature menu. The actual measured room 
temperature is displayed on the screen. 
The display exits the last selected menu section and moves to the Time menu. The current time is indicated on 
the screen. 
Beeper volume setting enables the user to change the volume of the display signals from 1 to 5 or switch the 
beeper off.
The beeper is off.

The sound level is 1.

...

...
The sound level is 5.

The controller information menu subsection. Used for service purposes.

Version of the controller main board.

Version of the controller display.

The service menu subsection. Access for the authorized service personnel only.

The random 4-digit number combination is indicated on the screen.

To modify the setup options, press 

 button to enter the Setup menu section. The set idle display brightness value is displayed. 

To move between the setup options, press 

 buttons to display the settings. To change a setting, press   button and use 

 

buttons to increase/decrease the selected values. When finished, press   button to confirm the set value.

8. MAINTENANCE AND CLEANING

Regular cleaning is of crucial importance for the continued operation of the stove. Failure to follow the cleaning schedule, or the use 

of dirty fuel can clog the inner spaces of the stove. These impurities can hinder air supply to the combustion chamber and cause the 

stove to stop working. To prevent this outcome, it is highly recommended that the user perform the cleaning activities specifically as 
described in the following chapters.

• CLEANING SCHEDULE

Tasks/ Frequency

Daily

Once per 2-3 days

Once per 30 days Once per 60-90 days Once per season

Fire pot cleaning

o

Ashes drawer emptying

o

Door glass cleaning

o

Flame trap cleaning

o

Exchanger tubes scraping

o

Combustion chamber vacuuming

o

Pellet hopper vacuuming

o

Flue channels cleaning

o

Door gasket changing

o

Chimney cleaning

o

Содержание P-7

Страница 1: ...Astra P 7 USER MANUAL CONTACT INFORMATION MACHINERY PLANT ASTRA AB ULONŲ G 33 LT 62161 ALYTUS LITHUANIA TEL 370 315 75449 E MAIL INFO ASTRA LT WWW ASTRA GAS LT ASTRA MACHINERY PLANT AB ANNO 1929 ...

Страница 2: ......

Страница 3: ...Power Regulation 17 Regulation of the RoomVentilator 18 Setting the Fuel Options 18 Modifying the Setup Options 18 8 MAINTENANCE AND CLEANING 19 Cleaning Schedule 19 Exterior Surfaces Cleaning 20 Heat ExchangerTubes Cleaning 20 Ashes Drawer Cleaning 20 Combustion Chamber Cleaning 21 Fire Pot Cleaning 21 Vermiculite Plates Cleaning 21 FlameTrape Cleaning 21 Flue Channels Cleaning 23 Pellet Hopper P...

Страница 4: ...le the stove is in operation its surfaces the glass the door handle and flue ducting become very hot Use extreme caution and be sure to use heat resistant personal protective equipment when touching these components Kindle the stove only after the daily inspection described in this manual has been performed To avoid a potential fire hazard do not dry laundry on or near the stove Keep clothes and o...

Страница 5: ...stovewithoutunpleasantinterruptions useonlyhigh quality6mmwoodpellets andkeepthecombustionchamber firepotandfluechannelsofthestovecleanedatalltimes 3 TECHNICAL DESCRIPTION Components of the stove Woodpelletsfromthehopper4aretransportedbymeansoftheauger5intothefirepot19 Fig 1 Theelectricaligniter18kindles the pellets The flame and hot flue gases rise to stainless steel heat exchanger 1 descend afte...

Страница 6: ...ces EN 60335 2 Safety particular requirements for fuel burning appliances having electrical connections EN 55014 1 EN 55014 2 EN 61000 3 2 EN 61000 3 3 Electromagnetic compatibility Model of the stove Astra P 7 Heat transfer medium Air Rated heating output 7 8 kW Reduced heating output 2 6 kW Period of complete burning of one full fuel load min max 9 30 hrs Weight 85 kg Height 910 10 mm Width 453 ...

Страница 7: ...5 18 16 17 L N 8 9 6 LCD 12 13 14 Fig 2 Circuit diagram of the stove Circuit Diagram The electrical circuit diagram of the stove is presented below in Fig 2 The denomination of elements is as follows T1 Room temperature sensor T2 Smoke temperature sensor B1 Electrical 250 W igniter M1 Fan 1 smoke exhaust fan M2 Fan 2 room ventilator M3 Auger gear motor SK1 Pellet hopper safety thermostat SK2 Diffe...

Страница 8: ...f the stove is important for the successful heating of the room Please take into account the next considerations before deciding where to place the stove If the supply air needed for combustion is to be taken from another room that room must be ventilated or have air inflow from outside Thestovecanconsumeupto40m3ofairperhouratmaximum sothesufficientamountofitmustbesuppliedeitherfrom outside or fro...

Страница 9: ...the front side It is recommended to increase the mentioned distances further if very easily flammable objects like curtains are present in the vicinity of the stove Fig 3 Chimney installed outside the house Yes YES NO FIG 6 FIG 9 YES FIG 10 Insulated flue Chimney cap for rain protection Insulated chimney tee with condensation drain pipe Fig 4 Incorrect installation with 90 bend as the first connec...

Страница 10: ...cap and a peephole Chimney cap for rain protection Thistypeofinstallation Fig 5 doesnotrequire aninsulatedflueasthesmokepipeisassembled partly inside the house and partly inside an existingflue Achimneyteewithapeepholecap isinstalledinthelowerpartoftheflue Please note the use of two 45 bends in order to guarantee that ash falls into the chimney tee withthecapandthepeephole This type of installatio...

Страница 11: ...of installation Fig 8 does not require an insulated flue for the part inside the house whereas for the outside part an insulated tube must be used A chimney tee with a peephole is installed in the lower part of the flue inside the house Another chimney tee is installed in the outside part of the flue making it available for inspection Sufficient draught is essential for the efficiency of all chimn...

Страница 12: ...potmayfalldownand harm the vermiculite plates The appliance should be carefully loaded unloaded and transported to avoid any significant impact The stoves can be loaded one on the top of another because the packaging is designed so that the stoves may be transported and stored in two decks However loading other objects on the top is prohibited as the packaging frame of the stove has been designed ...

Страница 13: ...her than force Therefore the display will not react if gloves are worn while attempting to use the controller Button Description This button is used to start and stop the combustion process in the stove The process is launched or stopped by pressing the button and holding it for 1 second Menu buttons are intended to navigate horizontally the controller menu look at the menu structure tree presente...

Страница 14: ...ou skip to the next subsection the number from 1 to 4 lights in the screen To modify a setting in the menu press button to enter the edit mode for the selected setting The screen value starts blinking Use buttons to change the value To move through the steps in the edit mode use buttons When finished press button to save the setting and exit the edit mode The display returns to the menu entry you ...

Страница 15: ...buttonandentertheeditmode With buttonschoosethedesiredvalue Weekly timer is switched off Weekly timer is switched on The icon in the indicator line lights permanently The first step in weekly timer programming is to describe the time intervals programs The description consists of specifying the interval start time the end time and the desired temperature Then the desired programs are assigned to e...

Страница 16: ...ogram number Press With buttons set the desired program number Press for confirmation Tuesday 3differentprogramscanbeassignedtoeachdayofaweek Press button and enter the desired values If only 2 programs are planned for a particular day choose option OFF for one of the entries With buttons set the desired program number Press With buttons set the desired program number Press With buttons set the de...

Страница 17: ...atthesametime themanually setroomtemperaturetemporarygainspriority Thisprioritydisappears whenthecurrentweeklytimerprogramends Whenthenext time program starts the room temperature again is controlled by the weekly timer To view a current room temperature press button to enter the Temperature menu section The actual measured room temperature value is indicated on the screen Actual measured room tem...

Страница 18: ...areexpressedinthefollowingvalues These values stand for the moisture content in pellets The dryer the fuel the higher fuel value in this menu section must be chosen The fuel quality option in this stove is deactivated The fuel value 1 is set irreversibly Modifying the setup options The Setup menu section enables you to set the options for Key lock Idle display brightness Idle display mode Beeper v...

Страница 19: ...l only The random 4 digit number combination is indicated on the screen Tomodifythesetupoptions press buttontoentertheSetupmenusection Thesetidledisplaybrightnessvalueisdisplayed Tomovebetweenthesetupoptions press buttonstodisplaythesettings Tochangeasetting press buttonanduse buttons to increase decrease the selected values When finished press button to confirm the set value 8 MAINTENANCE AND CLE...

Страница 20: ...e stove The pellet stove is a generator of heat and technically sophisticated appliance Therefore we strongly recommend servicing by qualified personnel at least onceayear atthestartoftheheatingseasontoascertain and ensure the continued function and efficiency of all the stove s components EXTERIOR SURFACES cleaning To clean the surfaces on the painted metal parts use a clothslightlymoistenedinwat...

Страница 21: ...nd shining look When combustion is regulatedproperly thesurfaceoftheseplatesremainscleanandwhite Thus theplatesactasindicator alightcolourindicatesthat the combustion quality is high a dark colour signals that combustion quality is poor Vermiculite plates do not require any specific maintenance Gentle cleaning with a brush to remove any ash residue is all that is necessary Donotuseanyabrasivespong...

Страница 22: ...22 Astra P 7 USER MANUAL Fig 18 Opening the inspection hatches of the flue channels Fig 18b Fig 18a Fig 17a Fig 17b Fig 17 Removing the top cover of the stove ...

Страница 23: ...Safety thermostat 2 Take out the display Use a PH1 size cross screwdriver to unscrew four screws fastening the case of the display Lift the display Fig 17a The display is connected to the controller board by RJ11 type data cable Do not forget to disconnect the cable before taking out the display 3 Remove the rooftop cover Unscrew six M5 bolts in the top rear side of the stove three on the left and...

Страница 24: ...s hopper Deletethealertbypressingandholding theStart stopbuttononthedisplay Combustion chamber or chimney is dirty Indication Icon Cleaning is blinking Indication Icon Cleaningis blinking Code A003 Code Cause The combustion chamber or the chimney are dirty and require cleaning There is too much ash or unburned pellets in the combustion chamber and or thechimneyiscongestedwithsoot Solution Inspect ...

Страница 25: ...up moment for example configuration data An unexpected error appears on the screen when making changes to the controller settings Solution disconnect and then reconnect the display to reset it If the problem persists contact service personnel for support Power supply failure During power supply failure the controller remains active due to internal battery Its internal status remains as it was befo...

Страница 26: ...e claims for such kind of damages should be presented to the vendor company the warranty term is not extended after removing the faults which have occurred during the warranty period cleaning of the stove and installation works are not covered by the warranty thedamagecausedtothepremisesandthepropertyinthepremises humanhealthduetothestovesfaultwillnotbecompensated the warranty repair works and rep...

Страница 27: ...on responsible for installation and testing Name surname signature of the employee I accept the installation works Name surname signature of the employee WARRANTY AND POST WARRANTY REPAIR CARD Pellet stove repaired by Company technician Address Telephone Repair date Information on fault works performed Signatureofthetechnician Pellet stove repaired by Company technician Address Telephone Repair da...

Страница 28: ...gnetic compatibility directive 89 106 EEC Construction products directive The following standards were applied for the Astra P 7 pellet stove EN 14785 Residential space heating appliances fired by wood pellets EN 60335 1 Safety of household and similar electrical appliances EN 60335 2 Safety particular requirements for fuel burning appliances having electrical connections EN 55014 1 EN 55014 2 EN ...

Отзывы: