8
EN
6. Technical information
Product - The Vault
Net weight........................................................................................................... 30 kg
Gross volume ....................................................................................................... 21 l
External dimension h, w, d...........................................................580 x 455 x 350 mm
Power input........................................................................................................180 W
Defrosting .................................................................................................... Automatic
Compressor ..........................................................................................................ACC
Energy consumption ...............................................................................1,5 kWh/24 h
Evaporator ................................................................................Finned coil evaporator
Condenser ................................................................................Finned coil condenser
Temperature control................................................................... Electronic thermostat
Lightning ....................................................................................................LED (RGB)
Climate class ............................................................................................................7*
*=Appliace is safety tested by SGS Fimko Ltd. in testroom c35°C/75% relative humidity.
Temperatures
Average temperature .................................................................. 3 °C (factory setting)
Operating conditions MIN .................................................................................. +12°C
Operating conditions MAX (75%RH) ................................................................. +38°C
7. Refrigerant
WARNING
The appliance contains in the refrigerant circuit the refrigerant propane
(R290), a highly environmentally compatible natural gas that is flammable.
While transporting and installing the appliance ensure that no parts of the
refrigerant circuit are damaged.
Procedure if the refrigerant circuit is damaged:
•
Avoid open fire and ignition sources at all costs
• Ensure that room in which the appliance is located is well ventilated
WARNING: Do not try to repair refrigerant circuit by yourself. Service and
repair work for refrigerant circuit must be always done by trained technician.