7
EN EN
EN
2. PUTTING INTO OPERATION
2.1. INSTALLATION
IMPORTANT!
Never move the appliance by grasping the edge of the glass sides.
Position the device where it is protected from
sunlight
and other
heat
sources
, since operation may be disturbed if the ambient temperature
e25°C
.
•
The appliance
should not be operated
in rooms where the
temperature
drops below +10°C
since this disrupts the lubrication
of the compressor.
Leave at least
10 cm space between the appliance’s side walls/roof/back
and neighbouring surfaces such as other devices, walls, furniture and ceiling to
provide free air flow behind the device to enable proper operation.
If the furnishing of the room allows positioning only close to the heat source
the following minimum clearances must be kept:
•
Put a
0.5-1 cm
thick insulation board between two devices if they
are
3 cm or less
apart.
•
Min. 30 cm from oil or coal-fired ovens.
IMPORTANT!
If the humidity is
above 60%
, condensation may occur on the glass.
2.2. ELECTRICAL CONNECTION
The appliance may be connected to
220-240 V
,
50 Hz mains
via properly
mounted grounded socket. Check if the voltage meets the local voltage and
make sure that the connecting cable isn’t stuck anywhere.
A fuse/circuit breaker of
10 A
is required for the operation of the appliance.
•
If the connection cable is damaged or it has to be extended, the
job must be done by a qualified electrician to avoid the dangerous
situations.
Do not use an extension cord!
The appliance must be positioned in a way
that the
main plug is easily accessible
.