Technical changes reserved. 08/2018
Page 1 of 8
A.S.T. - Angewandte System Technik GmbH, Mess- und Regeltechnik
Strain Gauge Measuring Amplifier BA 627
Original of the
Manual
Table of contents
1.
Safety precautions ........................................................................................................................ 2
1.1.
Field of application ................................................................................................................... 2
1.2.
Installation ................................................................................................................................ 2
1.3.
Maintenance ............................................................................................................................. 2
1.4.
Factory setting .......................................................................................................................... 2
2.
Operation ........................................................................................................................................ 3
2.1.
Overview operating elements BA 627 ...................................................................................... 3
2.2.
Sensitivity (S1) ......................................................................................................................... 3
2.3.
Signal output (S2, S4, S5) ........................................................................................................ 3
2.4.
Zero alignment (Zero >0<) ....................................................................................................... 4
2.5.
Zero range (S3-2) ..................................................................................................................... 4
2.6.
Amplification (Gain fine) ........................................................................................................... 4
2.7.
Cut-off-frequency (S3-1) .......................................................................................................... 4
2.8.
Test input ................................................................................................................................. 4
3.
Specifications ................................................................................................................................ 5
3.1.
General technical data ............................................................................................................. 5
3.2.
Connections ............................................................................................................................. 6
3.3.
Dimensions .............................................................................................................................. 7
4.
EC Declaration of Conformity ....................................................................................................... 8
A.S.T. - Angewandte System Technik GmbH, Mess- und Regeltechnik
Marschnerstraße 26 01307 Dresden
Telefon (03 51) 44 55 30 Telefax (03 51) 44 55 555
www.ast.de