Assi Control MP-2000 Скачать руководство пользователя страница 1

 

 

 

T a b l e   o f   c o n t e n t s  

M P   -   2 0 0 0  

 

X   /   2 0 0 9  

 

INTRODUCTION Page 

FAST START 

Page 

FUNCTIONS OF THE OPERATING KEYS 

Page 

 
IMPORTANT NOTES 

Page 

1.  Retention of the stored measured values  

when changing the battery 

Page 

2. Power 

supply 

Page  5 

3.  Checking the batteries or rechargeable batteries 
4. Automatic 

power-off 

Page  5 

5.  Changing the probe 

Page 

6. Battery 

check 

Page  5 

 
I. MENU 

OPERATION 

Page 

1. 

DC / AC / PEAK selection Page 

2. Display 

settings 

Page 7 

3. Memory 

settings 

Page 8 

4. 

Print & PC settings 

Page 

5. Setting 

options 

Page 

10 

 

 

II. MEASURING 

PROBES 

Page 

12 

III. 

CHECKING WITH THE PRECISION  
CALIBRATION STANDARD 

Page  13 

IV.  OPERATION WITH THE PRINTER 

Page  13 

V. INTERFACE 

SETTINGS 

Page 

13 

VI. SOFTWARE 

Page 

 

14 

TECHNICAL DATA 

Page  15 

MEGA-PRINT DATA PRINTER 

Page  16 

INTERNET SURVEY 

Page  17 

S T R U M E N T I  

&

  S E R V I Z I  

p e r   i l   s i s t e m a   q u a l i t à  

Via S. Silvestro, 92 21100 Varese
Tel + 39 0332 - 213045 

           212639- 220185 
Fax +39 0332 - 822553 
www.assicontrol.com 
e-mail: [email protected] 
C.F. e P.I. 02436670125  

Содержание MP-2000

Страница 1: ...DC AC PEAK selection Page 6 2 Display settings Page 7 3 Memory settings Page 8 4 Print PC settings Page 9 5 Setting options Page 10 II MEASURING PROBES Page 12 III CHECKING WITH THE PRECISION CALIBRATION STANDARD Page 13 IV OPERATION WITH THE PRINTER Page 13 V INTERFACE SETTINGS Page 13 VI SOFTWARE Page 14 TECHNICAL DATA Page 15 MEGA PRINT DATA PRINTER Page 16 INTERNET SURVEY Page 17 STRUMENTI SER...

Страница 2: ...you Which magnetic fields can the MP 2000 measure The MP 2000 field meter measures all practically occurring magnetic fields both DC and AC in a range from 0 1 to 40 000 A cm Oersted The device has two measurement ranges 0 199 9 A cm Oersted 200 40 000 A cm Oersted DC 200 20 000 A cm Oersted AC 1 A cm 0 1 kA m 1 256 Oe Gauss 0 1256 mT Measurement range switching takes place automatically The measu...

Страница 3: ...simply replace the cable in the event of a cable breakage The convenient menu operation in several languages allows simple operation of the device for the most part without an operating manual The MP 2000 offers the possibility to create up to 100 measurement storages total memory capacity 10 000 measured values Statistical evaluation takes place either on the display or by connecting a printer or...

Страница 4: ...en doing so The last measured value appears briefly on the display followed by the current measured value To change the language English is preset press the MENU key Scroll through the menu using the arrow keys confirm your selection using the OK key FUNCTIONS OF THE OPERATING KEYS DC AC PEAK Display Batch Print PC Setup Language LCD Light Unit Bat Voltage Reset DC AC PEAK Display Batch Print PC S...

Страница 5: ...onally appears on the display then the device switches itself off automatically for protection if the battery voltage is too low The exact battery voltage can additionally be displayed for checking purposes The battery voltage should be greater than 3 0 V Used batteries are special waste and must be disposed of accordingly 7 Automatic Power Off The device switches itself off automatically 2 minute...

Страница 6: ...und The selected menu item is called up via the OK key either a sub menu or the selected device function appears The C key is used to quit the device menu the main menu field is selected with the central blue key 1 DC AC PEAK Selection DC Field Switch to the DC steady field range in order to measure static fields The DC symbol is shown behind the current measured value on the display RMS AC Field ...

Страница 7: ...nd a higher meas ured value is recorded then the old measured value will be overwritten by the new one A short acoustic signal is sounded when the measured value is exceeded The peak value memory is reset via the 0 key When measuring AC fields in peak value memory mode the peak value and not the effective value will be saved if the AC field is sinusoidal 2 Display The various display functions of ...

Страница 8: ...cally adjusted according to the size of the current measured value Press once the right hand blue MEM key to save the current measured value in the batch memory Zero setting is carried out via the 0 key 3 Memory The MP 2000 contains a maximum of 100 different application memories for the saving and statistical evaluation of object related series of measurements A maximum of 10 000 measurements can...

Страница 9: ...f batch memories is selected here the max number of measured values that can be saved per memory is displayed at the same time 4 Print PC This menu item serves exclusively to send the stored measured data via the se rial interface to the MEGA PRINT printer or via the USB wireless interface to the PC In addition there is a possibility to send the current measured value to the PC every 0 5 sec in co...

Страница 10: ...the memories as otherwise the printer s paper consumption will be very high and the data transfer will take a very long time Current Transfer If this function is activated the current measured value will be sent to the USB wireless interface and the serial interface every 0 5 sec DC AC PEAK Display Batch Print PC Setup Print PC Send to PC Send to PC Print Values Print all Batches Current Transfer ...

Страница 11: ... V or less in order to save the battery Select measuring unit Gauss mT A cm kA m switching 1 A cm 0 1 kA m 1 256 Oe Gauss 0 1256 mT Display battery voltage The battery voltage should be greater than 3 0 V Language LCD Light Unit Bat Voltage Reset DC AC PEAK Display Batch Print PC Setup Deutsch English Spanisch Niederlande DC AC PEAK Display Batch Print PC Setup Language LCD Light Unit Bat Voltage ...

Страница 12: ...e distinguished by their design and measuring range as follows Table of available measuring probes Probe type Measuring range A cm Gauss Dimensions Axial field probes P A2 P A4 0 20 000 A cm Gauss 0 40 000 A cm Gauss Tangential field probes P T2 P T4 0 20 000 A cm Gauss 0 40 000 A cm Gauss Reed probes P Z2 P Z4 0 20 000 A cm Gauss 0 40 000 A cm Gauss 1 A cm 0 1 kA m 1 256 Oe Gauss 0 1256 mT A cali...

Страница 13: ...yed Compare the displayed value with that of the calibration standard IV OPERATION WITH THE PRINTER The device s interface parameters have been set in the factory so that the MEGA PRINT data printer available from us can be connected without having to change the interface parameters Operating instructions 1 Connect the printer cable to the device socket RS 232C and the printer 2 Switch on the MP 2...

Страница 14: ...alues into an existing Excel file STAT 6 statistics program This specially developed program features a graphical evaluation of the measured values as a bar and line chart with statistical evaluation and runs under Windows XP and Vista 32 bit You can also measure online using the STAT 6 program in conjunction with the MP 2000 The current measured value is shown in large characters on the screen so...

Страница 15: ...5 KHz Peak value memory PEAK HOLD Impulse duration 0 1 msec For use with measuring probes Axial and tangential field probes P A2 P T2 P Z2 P A4 P T4 P Z4 see Page 12 Power supply 3 x 1 5V AA Mignon alternatively 3 x 1 2V AA rechargeable Operating time Approx 100 hrs Automatic switch off 2 min if no change in measurement Battery indication X Measurement store 10 000 measurements Applications memory...

Страница 16: ... be at least 4 hours The green LED blinks during the charging process it lights steadily when the battery is fully charged The charger then switches automatically to maintenance charging mode The capacity of the rechargeable battery is sufficient for approx 60 hours of opera tion Notes on operation 1 The operation of the MEGA PRINT printer in conjunction with the MP 2000 mag netic field meter is e...

Страница 17: ...ntout The MEGA PRINT must be charged up again if individual lines of the printout are not printed correctly Inserting a new paper roll Open the cover Insert the paper roll Pull out the end of the paper Close the cover ...

Отзывы: