2.5.2 Battery-low warning
When the battery voltage in the door communication unit drops below a certain level,
a warning is given in the related corridor panel. If the battery voltage drops below a
critical level, the LCU will enter a state of access denied, i.e. it is no longer possible
to unlock the Allure lock with a card.
To be able to exchange the batteries in this case, follow the steps below:
1. In
Lock Service 3G
, choose
Parameters
in the left pane.
2. Click the
Readout
button; after this it will be possible to unlock the lock
with a card (will work twice, i.e. for steps 3 and 5 below).
Figure 48
3. Present a card at the lock to unlock it.
4. Exchange the batteries in the door communication unit.
5. Present the card at the lock to unlock it again.
Note:
An event about the battery exchange will be saved in the LockLog™. Choose
LockLog™
under
Readout
in the left pane of
Lock Service 3G
to read out a log.
The log can also be saved and will then be available under
Database
=>
LockLog™
2.5.3 Battery replacement
1. Open the door and remove the front end of the door communication unit.