4
800-810-WIRE (9473) • www.sargentlock.com • A7690C
4/15/08
Copyright
©
2008 SARGENT Manufacturing. All rights reserved.
Reproduction in whole or in part without the express written permission of SARGENT Manufacturing is pr
ohibited.
1. Prepare door according to template and instruction sheet supplied with exit device
2. Verify 1-1/8” mortise cylinder (size 41) is installed in rail insert with collar prior to installing exit
device on door
TO ADD OR REMOVE CYLINDER
1. Ensure power is disconnected
2. Separate circuit board and ground wire from mounting insert by
removing the four (4) screws from the under side
3. Once separated, slide cylinder through
collar into the insert as shown
NOTE: Orientation of the cylinder
Secure the cylinder with cylinder nut.
Tighten firmly
4. Re-attach circuit board and ground wire
to mounting insert with four (4) screws
5. Operate cylinder and verify cam is
operating switch properly
SARGENT
SARGENT
Collar
Cylinder Nut
DIP Switches
Top View
(LHRB shown)
Side View
Cam (cam engages switch)
SARGENT
SARGENT
Collar
Cylinder
Insert
Cylinder nut
Cylinder Installation
6
ORIENTATION OF CYLINDER
A7690C.indd 4
11/8/18 9:01 AM