19
A7690C • 800-810-WIRE (9473) • www.sargentlock.com
4/15/08
Copyright
©
2008 SARGENT Manufacturing. All rights reserved.
Reproduction in whole or in part without the express written permission of SARGENT Manufacturing is pr
ohibited.
Electroguard
™
Input/Output Diagram
11
Electrical Specifications
12
Page 24 Art
Input Voltage. . . . . . . . . . . . . . . . . . . 24VDC regulated/filtered
Power Consumption. . . . . . . . . . . . . 200 mA Unloaded (typical/standard), 500 mA Loaded (Optional Features)
Output Relays . . . . . . . . . . . . . . . . . . Form C, 1 Amp 24VDC
Operating Temp . . . . . . . . . . . . . . . . 0°C to 49°C (32°F to 120°F)
The following are the input and output connector designations.
Harness
Circuit
Connector
Board Input/
Harness
Function
Pin No.
Pin No.
Output
Wire Color
8-2
J1-1
input
Red
+24VDC power
8-1
J1-2
input
Black
-24VDC (Circuit Ground)
8-3
J1-3
input
White
Fire alarm contact
8-5
J1-4
input
Orange
External inhibit - disarm unit from
i/s or o/s (key switch, card reader, keypad)
8-6
J1-5
input
Blue
Door position sensor (Door Status/Monitor)
8-4
Chassis
Ground
Green
ESD (Earth) Ground
8-7
J2-1
output
Brown
Remote alarm relay (C.)
4-1
J2-2
output
Violet
Remote alarm relay (N.O.)
8-8
J2-3
output
Yellow
Remote alarm relay (N.C.)
4-2
J2-4
output
Grey
Latchbolt monitor relay (C.)
4-4
J2-5
output
Tan
Latchbolt monitor relay (N.O.)
4-3
J2-6
output
Pink
Latchbolt monitor relay (N.C.)
The Latchbolt monitor relay prevents the door from
being armed when latchbolt or vertical rods are
retracted
J2-7
output
Red/Green
Voice/Gang (C)
loose
J2-8
output
Red/Yellow
Voice/Gang (N.O)
wires
J2-9
output
Red/Black
Voice/Gang (N.C)
Voice Module 3071/3072 is required
NOTES:
1. Remote alarm relay shown in power “off” state. Power “on” relay energizes; contacts reverse state
2. Latchbolt monitor relay shown in power “off” state. Power “on” relay energizes; contacts reverse state
Page 24 Art
Page 24 Art
N.C. N.O. N.C.
A7690C.indd 19
11/8/18 9:02 AM