17
A7690C • 800-810-WIRE (9473) • www.sargentlock.com
4/15/08
Copyright
©
2008 SARGENT Manufacturing. All rights reserved.
Reproduction in whole or in part without the express written permission of SARGENT Manufacturing is pr
ohibited.
8900 Inside of door Dwg
Installing 59-8900/12-59-8900 Series Mortise Lock Exit Device
General Touch Bar
8900 Side View of Door Dwg
Lever
Lever arm
Latchbolt
Push Rail
MOUNT CHASSIS
Truss head
screws
Rail wire
& connector
Chassis
arm
Opening in
chassis for wire
Chassis
mounting
holes
Inside of door
8900 Mortice Lock Dwg
1. Feed wire and connector through chassis as shown
2. Snap the ElectroLynx connectors together and gather
excess wire in the top section of the chassis.
Wire tie in place
3. Finish installation per instruction sheet A6705 and
Section 10 within this manual
IMPORTANT: Surface of door where
exit device is to be applied must be
flush. Clear away any raised projections
to allow exit device to rest on flat
surface of door
8600 Verticlal Rod w/touchbar
Lock Down Key —
7/32” hex key
To operate: Depress
pushrail, insert hex key
and turn clockwise.
(Not furnished with 12-)
Push rail
Rail assembly
Exit Device Installation (continued)
A7690C.indd 17