Assa Abloy Sargent 2409 Series Скачать руководство пользователя страница 8

Wiring Diagram for 12-2409 to 2409/9-2409

2409/9-2409 Unit - 

24v ONLY

12-2409 Unit -120v or  

24v Input  

To Solenoid

To Solenoid

7 6 5 4 3 2 1

8 7 6 5 4 3 2 1

1

4

Field Wiring Provided by Others

Wire Nut or Splice Connector (Provided)

Interconnection Wiring Diagram

#1

#2

#3

#5

#4 

Remote

Detector

Relay

4

15

10

4

4

4

15

15

15

C

N.O.

8

Copyright © 2015, Sargent Manufacturing Company, an ASSA ABLOY Group 
company, All rights reserved. Reproduction in whole or in part without the 
express written permission of Sargent Manufacturing Company is prohibited.

A8200 (10/15)

Notes:

Five Detectors Maximum.

Use Terminals 4 and 15 to wire detectors in 
parallel (see #1,#2, and #3).

Use Terminal 10 to signal remote detectors 
with relay contact only (see #4 and #5).

Содержание Sargent 2409 Series

Страница 1: ...hru 8 of these instructions 24VDC 2409 Support Unit shown 12 2409 Master Unit shown Hinge Edge of Door Hinge Edge of Door Hinge Edge of Door INSTALLER LEAVE INSTRUCTIONS WITH BUILDING OWNER CAUTION 1...

Страница 2: ...s any of these parts could fail at any time Therefore test your smoke detector system per NFPA 72 Chapter 10 at least semiannually Clean and take care of your smoke detectors regularly Refer to Page 5...

Страница 3: ...elease their doors The unit that initiated the alarm will have its LED on The LED on the other interconnected units will flash as normal Refer to Interconnection Wiring Diagram for connections CONNECT...

Страница 4: ...h 4 pin jumper for non detectored units 120V AC INPUT CIRCUIT BOARD shown with Wiring Harness detectored units TWO PIN JUMPER WIRE SOLENOID CONNECTION WIRING HARNESS SEE PAGES 6 8 FOR ADDITIONAL WIRIN...

Страница 5: ...pen now Maintenance of Smoke Detectors It is recommended to clean smoke detectors at least every six months The frequency of cleaning will depend upon local ambient conditions The smoke detector in th...

Страница 6: ...VDC Solenoid Alarm Panel Alarm Circuit Trouble Circuit EOL Res 2 24VDC 0 15A Max To External Alarm 1 24V AC DC or 120V AC Input from Regulated Power Supply MPS10 or equiv 24V DC 0 15A Max To External...

Страница 7: ...or equiv Earth Ground 1 2 3 4 P1 P3 Circuit Board 2 1 3 Two Pin Jumper Wire 24VDC Solenoid 24V AC DC or 120V AC Input from Regulated Power Supply MPS10 or equiv Earth Ground 1 2 3 4 P1 P3 Circuit Boa...

Страница 8: ...2 3 5 4 Remote Detector Relay 4 15 10 4 4 4 15 15 15 C N O 8 Copyright 2015 Sargent Manufacturing Company an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the e...