Assa Abloy Sargent 2409 Series Скачать руководство пользователя страница 4

Support Unit Single Station Wiring Diagram

(24VAC/DC Input)

Support Unit Single Station Wiring Diagram

(120VAC Input)

Master Unit Single Station Wiring Diagram

(24VAC/DC Input)

Master Unit Single Station Wiring Diagram

(120VAC Input)

All wiring diagrams are shown with circuits energized in stand by mode.

Once alarmed, detector remains in alarm until reset by turning the reset switch on the detector.

Refer to ANSI NFPA 72 for recommended smoke detector applications.

Environmental limits:  100° F(38° C); 95% relative humidity; not for use where high concentrations of 
corrosive vapors exist.  Do not install where air velocity exceeds 30 ft. per minute.

24V AC/DC INPUT CIRCUIT 

BOARD

(shown with 4-pin jumper for non-

detectored units)

120V AC INPUT 

CIRCUIT BOARD

(shown with Wiring 

Harness detectored 

units)

TWO PIN JUMPER

WIRE

SOLENOID 

CONNECTION

WIRING 

HARNESS

SEE PAGES 6 - 8 

FOR ADDITIONAL 

WIRING OPTIONS

SOLENOID 

CONNECTION

120V AC 

POWER INPUT

TEST SWITCH

TEST SWITCH

24V AC/DC 

POWER INPUT

SOL

1

2

3

4

3

2

1

120VAC Circuit Board

4-Pin
Jumper

SOL

1

2

3

4

3

2

1

24VAC/DC Circuit Board

4-Pin
Jumper

4-PIN

JUMPER

SOL

1

2

3

24VAC/DC Circuit Board

1

2
3
4

5

6

7

8

9

10

11

12
13

14
15

Smoke

Detector

SOL

1

2

3

120VAC Circuit Board

1

2
3
4

5

6

7

8

9

10

11

12
13

14
15

Smoke

Detector

Fuse

PTO125V

(125V / 1/2A)

Fuse

PTO125V

(125V / 1/2A)

TWO PIN JUMPER

WIRE

4

Copyright © 2015, Sargent Manufacturing Company, an ASSA ABLOY Group 
company, All rights reserved. Reproduction in whole or in part without the 
express written permission of Sargent Manufacturing Company is prohibited.

A8200 (10/15)

Содержание Sargent 2409 Series

Страница 1: ...hru 8 of these instructions 24VDC 2409 Support Unit shown 12 2409 Master Unit shown Hinge Edge of Door Hinge Edge of Door Hinge Edge of Door INSTALLER LEAVE INSTRUCTIONS WITH BUILDING OWNER CAUTION 1...

Страница 2: ...s any of these parts could fail at any time Therefore test your smoke detector system per NFPA 72 Chapter 10 at least semiannually Clean and take care of your smoke detectors regularly Refer to Page 5...

Страница 3: ...elease their doors The unit that initiated the alarm will have its LED on The LED on the other interconnected units will flash as normal Refer to Interconnection Wiring Diagram for connections CONNECT...

Страница 4: ...h 4 pin jumper for non detectored units 120V AC INPUT CIRCUIT BOARD shown with Wiring Harness detectored units TWO PIN JUMPER WIRE SOLENOID CONNECTION WIRING HARNESS SEE PAGES 6 8 FOR ADDITIONAL WIRIN...

Страница 5: ...pen now Maintenance of Smoke Detectors It is recommended to clean smoke detectors at least every six months The frequency of cleaning will depend upon local ambient conditions The smoke detector in th...

Страница 6: ...VDC Solenoid Alarm Panel Alarm Circuit Trouble Circuit EOL Res 2 24VDC 0 15A Max To External Alarm 1 24V AC DC or 120V AC Input from Regulated Power Supply MPS10 or equiv 24V DC 0 15A Max To External...

Страница 7: ...or equiv Earth Ground 1 2 3 4 P1 P3 Circuit Board 2 1 3 Two Pin Jumper Wire 24VDC Solenoid 24V AC DC or 120V AC Input from Regulated Power Supply MPS10 or equiv Earth Ground 1 2 3 4 P1 P3 Circuit Boa...

Страница 8: ...2 3 5 4 Remote Detector Relay 4 15 10 4 4 4 15 15 15 C N O 8 Copyright 2015 Sargent Manufacturing Company an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the e...

Отзывы: