Assa Abloy SARGENT 1431 Скачать руководство пользователя страница 3

B

Door Closer Cycle

Opening
cycle

DOOR WIDTH

1431 DOOR CLOSER

(INCHES)

24-30

TURN nut 1-3 

30-36

FACTORY SET

36-42

TURN nut 1-3

42-48

TURN nut 7-9

FINAL ADJUSTMENT AND REGULATING PROCEDURES

7

8

ADJUST CLOSING POWER TO THE MINIMUM REQUIRED TO
RELIABLY CLOSE AND LATCH DOOR

9

INSTALL COVER AS SHOWN

3

SPRING POWER 

ADJUSTMENT GUIDELINES

SHORT SCREW

GAP

PLASTIC SPACER

AND LONG SCREW

MOVE

INSERT AS

NEEDED

10

SLIGHT TIGHTENING OR
LOOSENING OF HOLD OPEN
NUT CHANGES HOLDING
POSITION OF DOOR

NOTE:

ALWAYS USE A DOOR

STOP TO STOP DOOR TO
PROTECT WALL AND TRIM

ADJUSTMENT OF HOLD OPEN ARM
(PH10 ARM ONLY)

1-3/8" WRENCH

A7387D

– Adjust Door speed, and Latching speed valves to achieve the desired closing time. 

Recommend 6 seconds minimum from 90° to the closed position.

– If Backcheck is required, adjust valve to achieve a slight cushioning effect. 

Auxiliary stop required.

– If closer is equipped with Delayed Action, 

regulate valve to achieve the desired delay.

Latching speed range

Closing 
speed range

Backcheck range

Spring Power
Adjustment

Backcheck

Closing speed

Latching speed

Delayed

action

(Optional)

SLOW

DOWN

SPEED

UP

Delayed
action range

Use 1/8" hex wrench to

adjust valves

– If door is hard to open, decrease power

slightly

– If door does not latch, increase power 

as required

– Use the chart as a starting point

– Doors adjusted with high closing power 

to overcome strong draft conditions may
exceed ADA standards.  

Copyright © 2006-2008 SARGENT Manufacturing. All rights reserved. 
Reproduction in whole or in part without the express written 
permission of SARGENT Manufacturing is prohibited.

A7387C  1/30/08  3:17 PM  Page 3