INSTALLATION INSTRUCTIONS:
Seals Gap
Between a Pair
of Doors
DOOR
DOOR
(6)- #8 x 1 FHSMS
For attaching astragal to door edge.
(2)- #6 x 1/2 FHSMS
For attaching top bolt strike plate.
(4) 8-32 x 1/2 FHMS
For attaching strike plates.
(1)- Top Bolt Strike Plate
Installation Kit:
1.
Determine door and/or frame size.
If the frame is finished- a space for the Astragal must
be provided by trimming the edge of the inactive
door. See fig.1 for SLIMLINE and COLONIAL Style
Astragals and fig.2 for MORTISE Types.
If frame has not been fabricated- it can be sized so
that door edge need not be trimmed except to
remove bevel from inactive door. Construct frame
3/4” wider than total width of the doors for SLIMLINE
and COLONIAL Style Astragals and 3/8” wider for
MORTISE Types. In all cases, edge of inactive door
must be square.
• Strike Plates not furnished, use plates supplied
with locksets.
(1)- 3/32 Hex Key
For adjusting spring bolt locking
units (not included with slide bolt
astragals)
No. 3496 Colonial Style shown, others with locking spring
Bolts are No. 3492, 3494, and 3498.
Product / Finish
Tools Required
(not to scale - larger view inside)
C
o
lo
n
ia
l S
ty
le
w
it
h
S
lid
e B
o
lt
www.pemko.com