2
80-9357-0140-020 (09-10)
9. With door closed, slide Closed Position Magnet so it aligns with
the Reed Switch. See fig. 8.
10. Slide Open Position Magnet so it is 180° from the Reed Switch.
See fig. 9. Slide Open Position Magnet as needed to get proper
door opening.
11. Continue to page 4.
Fig.8
Closed Position
Magnet
Reed Switch
Fig.9
Open Position
Magnet
Reed Switch
7. Verify switch is in the “ON” position for the circuit breaker and
activate unit.
8. Immediately after activating the unit, watch the Cam Driver, fig. 6,
as it rotates around. As soon as the Cam Driver contacts the
Pinion Extension, flip the circuit breaker switch to the “RESET”
position.
Pinion
Extension
Cam
Driver
Pinion
Flat
Fig.6
Fig.7
Pinion
Extension
Cam
Driver
Pinion
Flat
Fig.11
Fig.10
Pinion
Extension
Cam
Driver
Pinion
Flat
These instructions are used to change the application of a LEO
operator from a Pull Side unit to a Push side unit.
®
12. The unit shown in fig.10 is configured for a pull side application.
Note the valve orientation of the closer body. The photo in fig.11
shows a close-up view of the clutch mechanism configured for pull
side application.
Instructions continued on page 3.