9. With door closed, slide Closed Position Magnet so it aligns with 

the Reed Switch.  See fig. 8.

10. Slide Open Position Magnet so it is 180° from the Reed Switch.  

See fig. 9.  Slide Open Position Magnet as needed to get proper 
door opening.

11. Continue to page 4.

Fig.8

Closed Position

Magnet

Reed Switch

Fig.9

Open Position

Magnet

Reed Switch

7.   Verify switch is in the “ON” position for the circuit breaker and 

activate unit.

8.   Immediately after activating the unit, watch the Cam Driver, fig. 6, 

as it rotates around.  As soon as the Cam Driver contacts the 
Pinion Extension, flip the circuit breaker switch to the “RESET” 
position.

Pinion
Extension

Cam

Driver

Pinion
Flat

Fig.6

Fig.7

Pinion

Extension

Cam
Driver

Pinion
Flat

Fig.11

Fig.10

Pinion

Extension

Cam
Driver

Pinion
Flat

These instructions are used to change the application of a LEO  

operator from a Pull Side unit to a Push side unit.

®

12. The unit shown in fig.10 is configured for a pull side application.  

Note the valve orientation of the closer body.  The photo in fig.11 
shows a close-up view of the clutch mechanism configured for pull 
side application.

Instructions continued on page 3.