80-9377-0601-020 (03-13)

Template

Right Hand Door Shown

 (Left Hand Installation is opposite.)

Preparation for Fasteners

Standar

d

Door or

Frame

Fasteners

Drill-Sizes

1/4" - 20

Machine Screw

Metal

Drill: #7 (0.201" dia.)
Tap:  1/4" - 20

Optional

Sex Nuts and Bolts

(SNB)

Hollow

Metal

9/32" (7 mm); through
3/8" (9.5 mm) on door or transom-face
opposite to closer

Aluminum

or Wood

3/8" (9.5 mm) through

• For 7570 MODELS ONLY

 set closer

  power for door size using chart below.

NOTE:

 Maximum of 16  360° turns

of Power Adjustment Nut

-

Turns from Zero

Interior Door Exterior Door

0

2

5

8

2

5

8

11

Door

Size

Inches

(mm)

28-32

(711-813)

33-36

(838-914)

37-42

(940-1067)

43-48

(1092-1219)

Install closer per instructions

with the proper pre-load 

applied to the arm then 

adjust spring power. The 

power adjustment will not

work properly if the closer

spring is not pre-loaded.

To increase power, use 11/16"

wrench to turn power

adjustment nut clockwise.

To decrease power, turn nut

counter clockwise.

 

DO NOT use a power drill or 

driver to turn adjustment nut. 

This will damage

closer and void

 warranty.

"Spring Power

Adjustment Nut"

+

-