Assa Abloy Norton 6300 Series Скачать руководство пользователя страница 11

Copyright © 2017 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved. 
Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited. 

80-9363-0001-020 Rev 7 08/17

Page 11

 

Opening and Closing Adjustments

12

A. Turn potentiometers (shown below) to make any adjustments. The table below shows the times 

required per ANSI/BHMA A156.19 (American National Standard for Power Assist and Low Energy 
Power Operated Doors) for opening and closing based on the door width and weight.

Opening Speed 
Adjustment

Sweep Speed Adjustment
(Speed of door closing from 
open to Latch Speed Range)

Latch Speed Adjustment
(Speed of door closing 
from Sweep/Latch 
transition point to close)

Hold Open Delay
(5-30 sec)

Open Delay 1
(Delay before door opens 
after an activation from 
Input 1)

Open Delay 2
(Delay before door opens
after an activation from 
Input 2)

Contact Factory for 
assistance with 
additional settings

Available adjustment for 
Special Application 
Requests

Increase

Decrease

Содержание Norton 6300 Series

Страница 1: ...ools required Use screw pack and hardware provided to mount operator ETL certified conforms to ANSI UL standard 325 for automatic closing doors and UL10C Positive Pressure Fire Test for Door Assemblie...

Страница 2: ...tion Opening and Closing Adjustments Setting Accessory Dip Switches Connecting Inputs Cover Installation Troubleshooting Pull Side Template Page 3 Page 4 Page 5 Page 7 Page 8 Page 9 Page 10 Page 11 Pa...

Страница 3: ...aluminum No 14 x 2 3 4 70mm long sheet metal screws for wood Door Prep Page 3 Standards ETL Certified conforms to ANSI UL standard 325 for automatic closing doors and UL10C Positive Pressure Fire Test...

Страница 4: ...screws If self drilling self tapping screws are used drill first mounting hole using a 3 16 drill and supplied screw Note Holes used for mounting the Back Plate are marked with a center mark on pull s...

Страница 5: ...pad can compress as screws are tightened make sure to double check screws for tightness Power Supply Board Assembly Installation 4 A Install 2 1 4 20 x 3 8 length cap screws in the top two tapped hole...

Страница 6: ...ng connector on the board closest to the frame attach the Back Plate Ribbon Harness to the board NOTE The connectors on the harness are keyed to allow for proper installation see illustration below Wh...

Страница 7: ...ely 30 and mate the slider in the track to the tapped hole on the end of the arm Use the 3 16 hex wrench to rotate the slider bolt counter clockwise until the slide is tight in the arm Conduit Holes E...

Страница 8: ...feels from the door opening and closing during manual use is controlled by this function B If required adjust the closing force nut in the end of the tube to the desired setting using a 3 4 deep well...

Страница 9: ...set for standard applications Fine tuning may be required for speci c applications Normally Closed 24VDC Output On the control board there should be one solid red LED for POWER one white LED that flas...

Страница 10: ...tion and hold the door there NOTE If there is a wall or door stop at the open position do not hold the door against the wall or stop Press and release the OPEN button on the board see illustration at...

Страница 11: ...andard for Power Assist and Low Energy Power Operated Doors for opening and closing based on the door width and weight Opening Speed Adjustment Sweep Speed Adjustment Speed of door closing from open t...

Страница 12: ...h for Special Application Requests Spare 2 Available Dip Switch for Special Application Requests Connecting Inputs 14 A Use green 2 position connectors attached to board to add any necessary inputs to...

Страница 13: ...ruction Input 8 Obstruction 2 Contact closure of this input while the door is closed or opening triggers the operator to stall If the contact is not removed after 10 seconds of closure the operator wi...

Страница 14: ...ocess If the door hit an obstruction reset to factory defaults by pressing and holding the POWER button until all LEDs light up then release Repeat Step18 to set Open and Closed Positions and Learn pr...

Страница 15: ...late Copyright 2017 Yale Security Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibited 80 9363...

Отзывы: