Set Application

10

A. Determine if unit is Push or Pull. If Push 

application, the door opens away from you. If 
Pull application, the door opens toward you.

B. Flip the PUSH/PULL ARM dip switch to OFF for 

a Push application or ON for a Pull application. 
See Illustration at right.

Set Door Open and Closed Position

11

A. To set the closed position, fully close the door. 

Press and release the CLOSE button on the 
board (see Illustration at right). The flashing 
ORANGE LED should turn solid. 

NOTE:

 Any 

time the door is in the closed position, the 
orange LED should be solid.

B.  The GREEN OPEN LED should now be 

flashing. To set the fully open position, manually 
open the door to the open position and hold the 
door there. 

NOTE:

 If there is a wall or door stop 

at the open position, do not hold the door 
against the wall or stop.  

     Press and release the OPEN button on the 

board (see illustration at right). The flashing 
GREEN OPEN LED should turn solid. 

NOTE:

 

Any time the door is in the open position, the 
green LED should be solid. 

If the open 

position is not set within 30 seconds of 
setting the closed position in Step 11A, then 
Step 11 must be repeated.

C. Once door has fully closed after Step 11B, 

make sure there are no obstructions that could 
prevent the door from opening. Latching 
hardware must not prevent the door from 
opening during the following step.

D. The operator must now learn its internal 

settings. Press and release the LEARN button 
on the board (see illustration at right). The 
BLUE LEARN LED will start flashing and the 
door will open in small increments. Allow the 
door to open and close without interference. 

NOTE:

 If the spring is adjusted or accessories 

are attached to the door that would make the 
door heavier, 

Step 11D MUST be repeated

.

LEARN
button

CLOSE
button

OPEN
button

OFF   ON

Содержание Norton 6300 Series

Страница 1: ...ools required Use screw pack and hardware provided to mount operator ETL certified conforms to ANSI UL standard 325 for automatic closing doors and UL10C Positive Pressure Fire Test for Door Assemblie...

Страница 2: ...tion Opening and Closing Adjustments Setting Accessory Dip Switches Connecting Inputs Cover Installation Troubleshooting Pull Side Template Page 3 Page 4 Page 5 Page 7 Page 8 Page 9 Page 10 Page 11 Pa...

Страница 3: ...aluminum No 14 x 2 3 4 70mm long sheet metal screws for wood Door Prep Page 3 Standards ETL Certified conforms to ANSI UL standard 325 for automatic closing doors and UL10C Positive Pressure Fire Test...

Страница 4: ...screws If self drilling self tapping screws are used drill first mounting hole using a 3 16 drill and supplied screw Note Holes used for mounting the Back Plate are marked with a center mark on pull s...

Страница 5: ...pad can compress as screws are tightened make sure to double check screws for tightness Power Supply Board Assembly Installation 4 A Install 2 1 4 20 x 3 8 length cap screws in the top two tapped hole...

Страница 6: ...ng connector on the board closest to the frame attach the Back Plate Ribbon Harness to the board NOTE The connectors on the harness are keyed to allow for proper installation see illustration below Wh...

Страница 7: ...ely 30 and mate the slider in the track to the tapped hole on the end of the arm Use the 3 16 hex wrench to rotate the slider bolt counter clockwise until the slide is tight in the arm Conduit Holes E...

Страница 8: ...feels from the door opening and closing during manual use is controlled by this function B If required adjust the closing force nut in the end of the tube to the desired setting using a 3 4 deep well...

Страница 9: ...set for standard applications Fine tuning may be required for speci c applications Normally Closed 24VDC Output On the control board there should be one solid red LED for POWER one white LED that flas...

Страница 10: ...tion and hold the door there NOTE If there is a wall or door stop at the open position do not hold the door against the wall or stop Press and release the OPEN button on the board see illustration at...

Страница 11: ...andard for Power Assist and Low Energy Power Operated Doors for opening and closing based on the door width and weight Opening Speed Adjustment Sweep Speed Adjustment Speed of door closing from open t...

Страница 12: ...h for Special Application Requests Spare 2 Available Dip Switch for Special Application Requests Connecting Inputs 14 A Use green 2 position connectors attached to board to add any necessary inputs to...

Страница 13: ...ruction Input 8 Obstruction 2 Contact closure of this input while the door is closed or opening triggers the operator to stall If the contact is not removed after 10 seconds of closure the operator wi...

Страница 14: ...ocess If the door hit an obstruction reset to factory defaults by pressing and holding the POWER button until all LEDs light up then release Repeat Step18 to set Open and Closed Positions and Learn pr...

Страница 15: ...late Copyright 2017 Yale Security Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibited 80 9363...

Отзывы: