Assa Abloy Lockwood 5831 Series Скачать руководство пользователя страница 8

8

Lockwood Product Catalogue | 5831 Series

  

Low Energy Operator 

1300 LOCK UP (1300 562 587) 

lockweb.com.au

5831 Series Low Energy Operator

Low Energy vs Full Energy Operators: Which is 

right for my project?

Here are criteria to help you answer the question: Is my 
project better suited to low or high energy door operators?

The 5831 Series is designed, built and tested in a state-of-the-art 
facility in Monroe, North Carolina, USA . The information below is 
designed to help you determine if a low energy operator is right for 
your application .

They can be found in entrances to public buildings, including 
schools, libraries, museums, offices and government buildings .

PROJECT  

TYPE

Is this an entirely new project 

or a retrofit project for which 

you must use an existing door 

system?

NEW

New construction projects may specify high or low energy door 

operators or a combination of both, depending on the intended use.
In retrofit projects, installing high energy operators is possible, though 

costly, because it requires removal of the entire door frame for add 

following: and a structural beam above the door for support.
Low energy operators can be installed on any existing door system.

RETROFIT

INTENDED  

USE

Are openings required to 

be accessible by mobility 

challenged individuals? (Usage 

expectations and relevant 

compliance standards will 

determine this.)

YES

Modern, low energy door operators enable smooth and quiet door 

operation, much like an ordinary door. They can be used manually the 

majority of the time and used automatically on occasion by mobility-

challenged individuals.
Low energy operators provide access to mobility-challenged 

individuals without requiring them to push or pull open the door in 

front of their path of travel.

NO

TRAFFIC  

VOLUME  

& FLOW

What is the expected traffic flow 

and volume of usage?

HIGH

Low energy operators are often suitable for high and low traffic areas. 

Some models are designed with a regenerative power system, which, 

during manual operation, charges an onboard battery pack used 

during automatic operation.
This feature eliminates the need to run electrical wire to the unit. High 

energy operators are designed to operate quickly and continuously for 

convenience (for example, in supermarkets and hospital emergency 

rooms).

LOW

COST OF 

OWNERSHIP

What is the overall cost of 

ownership, including installation 

cost, lifetime energy costs and 

maintenance costs?

HIGH

High energy door operators are often packaged for sale with an annual 

maintenance agreement to ensure the doors continue to operate 

safely. In addition, installation costs for high energy operators have 

been estimated to be twice that of low energy operators.
Some low energy operators have been designed to be installed and 

serviced by existing facility maintenance staff, consume minimal 

electrical power each year, and require no formal maintenance 

agreements.

LOW

ACCESS  

CONTROL  

/ SECURITY

Is it necessary to control who 

has access to particular areas? 

In other words, is access control 

required?

YES

When necessary, low energy operators can be integrated with electric 

locking devices for complete access control.

NO

Содержание Lockwood 5831 Series

Страница 1: ...We take the worry out of protecting what s valuable to you Lockwood no worries www lockweb com au 5831 Series Low Energy Operator...

Страница 2: ...ess Interface Module 10 Product Dimensions 11 Accessories 12 Kits 13 How to order 14 As one of the world s only regenerative power door operators The Lockwood 5831 Series is a heavy duty low energy do...

Страница 3: ...tery placing the battery in any part of the body or swallowing may lead to serious injury Ifyoususpectyourchildhasswallowedorinsertedabuttonbattery seekmedicalattentionimmediately o Australia Call the...

Страница 4: ...en applied using the 80 25 guideline the operator will self generate all the power it needs to keep its field replaceable onboard battery pack charged A fully charged battery has the capability to ope...

Страница 5: ...and no low voltage license Installed similar to a manual door closer in less than an hour A scalable solution in either Regenerative or Powered modes Integrates into existing Access Controlled enviro...

Страница 6: ...king Braking or slowing of the door if excessive door speed occurs resulting from a wind load or an abusive open condition Emergency Interface Relay Door closes and ignores any activation input until...

Страница 7: ...elp determine the correct Swing Door Operator product to select If in any doubt it is recommended to forward through the enquiry to ASSA ABLOY Entrance Systems Low Energy vs Full Energy Operators 5831...

Страница 8: ...y can be used manually the majority of the time and used automatically on occasion by mobility challenged individuals Low energy operators provide access to mobility challenged individuals without req...

Страница 9: ...RGY OPERATORS Building Standard AS5007 2007 Powered Doors for Pedestrian Access and Egress Has the ability to meet the requirement AS5007 2007 Powered Doors for Pedestrian Access and Egress Speed of O...

Страница 10: ...scription The Wireless Interface Module allows the 5831 Series door operator to interface to 5800 wired or wireless push buttons wireless remote an electric lock fire panel access control and an outsi...

Страница 11: ...roduct Catalogue 5831 Series Low Energy Operator 1300 LOCK UP 1300 562 587 lockweb com au Product dimensions Push Side Pull Side All dimensions are approximate 460mm 292mm 184mm 83mm 38mm 38mm 216mm 2...

Страница 12: ...24V direct replc of former 1015 transformer armored dr cord end links 50 of low voltage cable power port cnt Accessories ADA1002 Operator Cover Black ADA1006 Operator Mounting Bracket with covers ADA1...

Страница 13: ...Kit 5831AUXNPB with ADA1021 Pull Side Conversion Kit OR Compliance to AS1428 1 Where used in applications specifically intended to meet the requirements of AS1428 1 it is recommended that these steps...

Страница 14: ...2 x Wireless Narrow Push Bottons Contiuous Powered 5831AUXNPB ADA1015T 24V Operator Push Side Arm Assembly 2 x Wireless Narrow Push Bottons 24V Hardwire Kit Integrated 5831AUXNPB ADA1015T 24V ADA1028W...

Страница 15: ...5831 Series Low Energy Operator 15 Lockwood Product Catalogue 5831 Series Low Energy Operator 1300 LOCK UP 1300 562 587 lockweb com au...

Страница 16: ...et place is backed by the Lockwood 25 Year Mechanical Warranty ensuring that Lockwood continues to keep Australians safe by delivering security and peace of mind For warranty terms and conditions plea...