background image

17

Definitions

All Code Lockout Mode:

 

This feature is enabled by the Master PIN Code. When enabled, it restricts all 

user (except Master) PIN Code access. When attempting to enter a code while the unit is in Lockout, the 

RED locked padlock will appear on the screen.

Automatic Re-lock Time: 

After a successful code entry and the unit unlocks, it will automatically re-lock 

after thirty (30) seconds.

Inside Indicator Light: 

Located on the interior escutcheon. Shows active status (Locked) of lock and can 

be enabled or disabled in the 

Advanced Lock Settings

 (Main Menu selection #3).

Language Setting Mode: 

Choosing English (1), Spanish (2) or French (3) becomes the (default) setting for 

the lock’s voice prompts

.

Low Battery: 

When battery power is low, the Low Battery Warning indicator flashes RED. If battery power 

is completely lost, use the 9 Volt battery override. To use the 9V battery override apply 9V battery, in either 

direction, to terminals below the touchscreen for backup power option. Wake up the lock and enter your 

PIN Code to unlock the door.

Master PIN Code: 

The Master PIN Code is used for programing and for feature settings. 

It must be 

created prior to programming the lock.

 The Master PIN Code will also operate (unlock/lock) the lock.

Network Module Settings: 

With the optional Network Module installed, this setting becomes available thru 

the Main menu (7) and allows the lock to connect with a network controller.

One Touch Locking: 

When the latch is retracted, activating the keypad will extend the latch (during 

Automatic Re-lock duration or when Automatic Re-lock is disabled). When One-Touch Re-lock is 

not

 in 

use 

(disabled)

, any valid PIN Code will re-lock the lock.

Previous: 

While in Menu Mode, pressing this icon cancels the current operation and returns the user to the 

previous step.

Privacy Mode: 

Privacy mode is disabled by default Privacy mode is enabled/disabled in the app.

Shutdown Time: 

The unit is shutdown (flashing RED) for sixty (60) seconds and does not allow operation 

after the wrong code entry limit (5 attempts) has been met.

Tamper Alert: 

Audible alarm sounds if attempting to forcibly remove outside lock from door.

User PIN Code: 

The User Code operates the lock. Maximum number of User Codes is 250 with Network 

Module; without Network Module maximum is 25 User Codes. Note: When deleting User Code(s), screen 

will display User Number (not code) being deleted.

Volume Setting Mode: 

The volume setting for PIN Code verification is set to 

Low (2)

 by default; otherwise 

it can be set to 

High (1) 

or 

Silent (3)

 for quiet areas.

Wrong Code Entry Limit: 

After five (5) unsuccessful attempts at entering a valid PIN Code, the unit will 

shut down and not allow operation.

Содержание Emtek EMPowered

Страница 1: ...EMPowered Motorized Touchscreen Keypad Deadbolt...

Страница 2: ...16 Machine Screws x4 8 x 3 4 Wood Screws x2 10 32 x 1 3 8 Machine Screws x2 10 x 3 Wood Screws AA x4 Batteries Security Plate Strike Plate Battery Cover Mounting Plate Interior Escutcheon Deadbolt La...

Страница 3: ...3 Door Prep Door Jamb Prep 2 3 8 or 2 3 4 Backset 2 1 8 Diameter Bore 1 8 Deep 2 1 4 1 1 Diameter Edge Bore 2 3 4 3 16 Deep 2 3 4 1 1 8 3 4 1 1 4 1 1 4 Deep...

Страница 4: ...4 Install Latch Strike Plate Bolt must be in retracted unlocked position Note horizontal orientation of mechanism 1 x2 x4 Note Use only the supplied latch for proper functionality...

Страница 5: ...5 Install Touchscreen Escutcheon 2 Outside of the door Inside of the door...

Страница 6: ...6 Install Interior Mounting Plate 3 Loosen screw to remove cover x2...

Страница 7: ...7 Connect the Cable Assembly 4...

Страница 8: ...8 Install Interior Escutcheon 5 x3 See comment about reset button on page 16 Resetting Lock to Factory Default...

Страница 9: ...9 Testing Operation 6...

Страница 10: ...10 Bolt must be in retracted unlocked position before installing batteries Install Batteries 7...

Страница 11: ...11 Install Cover 8 Secure cover by tightening screw on bottom...

Страница 12: ...12 Handing the Lock Activate the Lock OR Handing Lock Handing Lock Complete...

Страница 13: ...ting the lock to factory default Programming and use of lock is not possible until this step has been successfully completed Enter a 4 to 8 digit PIN Code followed by the gear key Registered Press Pre...

Страница 14: ...des 25 without Network Module Enter Master PIN Code Press Enter 4 8 digit PIN Code Press code flashes To end programming Adding more User Codes Press Menu Mode enter number press the gear key to conti...

Страница 15: ...ss PIN Code Management With Network Module Up to 250 Users User Type User Name User PIN Code Master User____ User____ User____ User____ User____ User____ User____ User____ User____ User____ User____ U...

Страница 16: ...einstall batteries Release reset button 5 Replace battery cover Upon reset Master PIN Code creation is the only option available and must be performed prior to any other programming of the lock Factor...

Страница 17: ...ock Network Module Settings With the optional Network Module installed this setting becomes available thru the Main menu 7 and allows the lock to connect with a network controller One Touch Locking Wh...

Страница 18: ...Lock Response Menu mode enter number press key to continue 3 Enter digit corresponding to the function to be performed followed by the key Follow the voice commands The Master PIN Code must be registe...

Страница 19: ...French Delete M U U U Continue Continue Continue Complete Complete Complete User PIN Code Registration Handing the Lock 1 1 1 1 2 2 1 1 3 3 3 3 3 PIN PIN PIN PIN 2 5 Volume Settings 4 Language Setting...

Страница 20: ...l not auto matically re lock Check to see if Auto Re lock Mode is enabled Disable Auto Re lock Mode to lock the door automatically If low battery indicator is lit see below change batteries PIN Codes...

Страница 21: ...made to bolt c Verify proper door preparation and re bore holes that are too small or misaligned d Verify keypad wire harness is routed under the bolt see Fig A e Verify bolt is installed with correc...

Страница 22: ...allation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the int...

Страница 23: ...cm between the radiator your body INDUSTRIE CANADA CONFORME Ce dispositif est conforme la norme CNR 210 d industrie Canada applicable aux appareils radio exempts de licence Son fonctionnement est suje...

Страница 24: ...te of California to cause cancer and birth defects or other reproductive harm For more information go to www P65Warnings ca gov Copyright 2019 EMTEK Products Inc an ASSA ABLOY Group company All rights...

Отзывы: