14
EN
Connection assignment (refer to connection diagram in assembly
instructions)
Terminal Connection
Description
1
24 V DC
Input for external voltage supply
2
0 V DC
Input for external voltage supply
3
0 V DC
Output for locking element (maximum 380 mA)
4
24 V DC
5
Terminals for manual triggering button (NOC)
6
When a manual triggering switch is connected:
Remove plug-in bridge J1 (black).
7
24 V DC
Voltage supply for external smoke switch
8
GND
9
Alarm contact
Input for additional external smoke switch with
cable monitoring
When an additional external smoke switch is
connected: Remove plug-in bridge J2 (red).
Alarm relay as a potential free inverter, maximum 1 A / 24 V DC (resistive load)
10
Contact (NC)
11
Middle contact (C)
12
Normally open contact (NOC)
Plug-in sockets
· Plug-in socket, grey:
Output for voltage supply, locking element sliding rail
· Plug-in socket, white:
Input for voltage supply, smoke switch
I
I
Electrical
connection