ASSA ABLOY Entrance Systems AB

We

Lodjursgatan 10
SE-261 44 Landskrona
Sweden

declare under our sole responsibility that the type of equipment:
RD3, RD4, RD3 A1, RD4 A1, RD4 A2

complies with the following directives:

2014/30/EU ElectroMagnetic Compatibility Directive (EMCD)
2006/42/EC Machinery Directive (MD)
2011/65/EU on the restriction of the use of certain hazardous substances in electrical and electronic equipment
with the applicable amendments (RoHS)

Harmonized European standards which have been applied:

EN 60335-1:2012+A13:2017

EN ISO 13849-1:2015

EN 61000-6-2:2005

EN 60335-2-103:2015

EN 16005:2012/AC:2015

EN 61000-6-3:2007+A1:2011

Other standards or technical specifications, which have been applied:

IEC 60335-2-103 ed. 2:2006+A1:2010

IEC 60335-1 ed. 5:2010
EN 1627:2011 Class RC3

Certificate issued by a notified or competent body (for full address, please contact ASSA ABLOY Entrance Systems
AB) concerning the equipment:

SC0834-14

BY/112 02.01. 020 08532
TÜV B 058029 0045

The manufacturing process ensures the compliance of the equipment with the technical file. The manufacturing
process is regularly assessed by 3rd party.

The CE mark was first applied 2004-03-24.

Compilation of technical file:
Anders Forslind
ASSA ABLOY Entrance Systems AB
Lodjursgatan 10
SE-261 44 Landskrona
Sweden

Position

Signature

Date

Place

Global Quality Manager

Klas Hagelin

2020-10-08

Landskrona

Declaration of conformity

DoC 701475-en-22.0

1003090-en-12.0

Issue 2020-10-09

34

Содержание CDC 4

Страница 1: ...Original instructions User Manual Entrance Systems Revolving Doors ASSA ABLOY RD3 RD4 CDC 4 ...

Страница 2: ...al information PCD 9 Information prompts on PCD display 10 Access code 11 Changing operating mode 13 Real time operation 16 Safety 16 Safety devices on the door 17 Pressure sensitive safety edges 17 Force sensitive door leaves 17 Emergency stop button 18 Regular safety checks 21 Troubleshooting 22 Supervision system 22 Code List 23 Service Maintenance 23 Service request 24 Remote Control Operation...

Страница 3: ...ake lock 30 Electromechanical lock 30 Direction sensing radar DSR 31 Night closing door NCD 31 Reception panel 32 Quick guide changing operating mode 33 Other products from ASSA ABLOY Entrance Systems 34 Declaration of conformity ASSA ABLOY as word and logo are trademarks owned by the ASSA ABLOY Group ASSA ABLOY Entrance Systems 2020 Technical data subject to change without notice Backtrack inform...

Страница 4: ...ars of age if they have been instructed by a person in charge of their safety The operator can be used by children 8 years of age or younger if they are supervised by a person respons ible for their safety The operator can be used by persons with impaired physical sensory or mental capacity if they have been instructed by a person in charge of their safety Cleaning and user maintenance shall not b...

Страница 5: ...e user is encouraged to try to correct the interference by one or more of the following measures Re orient the receiving antenna Relocate the receiver with respect to the equipment Move the receiver away from the equipment Plug the receiver into a different outlet so that equipment and receiver are on different branch circuits Check that protective earth PE is connected Ifnecessary theusershouldco...

Страница 6: ...s or delays in deliveries by sub contractors caused by any such cir cumstances Please note Non compliance with manufacturers care and maintenance recommendations may void the warranty ASSA ABLOY Entrance Systems authorizedresellersshallextendthiswarrantytoend usersonly but have no authority to extend a greater or different warranty on behalf of ASSA ABLOY Entrance Systems A service agreement with ...

Страница 7: ...e unit max 400W LED spot lights max 60W LED panel lights max 150W Power consumption 20 to 50 C Temperature range IP20 Degree of protection IP54 Degree of protection control actuators Sound pressure Third party approvals from established certification organizations valid for safety in use see Declaration of Conformity Approvals How the ASSA ABLOY RD3 and ASSA ABLOY RD4 work The door is designed so ...

Страница 8: ...otate 360 option 1 Main control unit CDC 4 behind fascia sheets 2 Vertical presence photocell sensor PDR option 3 Dust protection roof max load 0 kg Do not walk or store any material on the roof 4 Program Control Device PCD with ON OFF key switch standard place 5 Emergency stop button 6 EMERGENCY OPENING button option 7 Activation by disabled people Recommended if applicable option 8 Door leaves w...

Страница 9: ...tion upwards Setpoint selection downwards Setpoint value change upwards Setpoint value change downwards Function selection F Setpoint confirmation and storage S Error clear 20 30 Clear display Leave menu C ON OFF switch 1 ON 0 OFF ILL 01914 Information prompts on PCD display FUNC DATA EAA156 P1 P2 P3 Description Prompt ON OFF switch in OFF position P1 Service request Call ASSA ABLOY Entrance Syste...

Страница 10: ... display 2 Enter the access code The display shows 3 Press to confirm the input If the access code is correct the display shows LO Logout 0 1 Level 01 4 Automatic logout ten minutes after the last key press 5 Automatic logout can be inhibited by typing F561 on the PCD Change access code At delivery the access code is 1234 To change follow the procedure below 1 Type 1234 If the access code is corre...

Страница 11: ...N OFF switch it can be opened with a key switch ask your local ASSA ABLOY Entrance Systems Service When the key switch is activated the door unlocks runs 360º and locks again Changing operating mode 1 Login on the PCD 1 2 4 5 7 8 0 3 6 9 F S C on FUNC DATA Access code ILL 01894 0 1 2 Type F2 The display shows F2 plus current operating mode 3 Use the up or down arrow to change the operating mode 01...

Страница 12: ...tion on page15 ILL 00180 Key impulse switch Automatic operation 02 The door is parked in standby position when there is no traffic As soon as the outside or inside ac tivation units detect approaching traffic the door starts rotating ILL 00189 Continuous rotation 06 The door rotates at a low speed As soon as the outside or inside activation units detect approaching traffic the door accelerates to ...

Страница 13: ...4 3 6 1 1 0 1 8 7 9 1 2 1 2 5 4 3 6 1 1 0 1 8 7 9 1 Deactivation Type F557 Real time operation OFF Prompt P3 extinguishes The door operates according to manually set operating mode EAA204 0 1 ON OFF switch The OFF 0 position overrides real time operation The door will be locked When set to the ON 1 position the door resumes operation according to schedule Manual setting of operating mode If the do...

Страница 14: ...9 10 10 10 Week schedule Schedule Week day Monday Tuesday Wednesday Thursday Friday Saturday Sunday Exceptions Exception schedule End exception Start exception 1 1 1 2 2 2 3 3 3 4 4 4 5 5 5 6 6 6 7 7 7 8 8 8 9 9 9 10 10 10 11 11 11 12 12 12 13 13 13 14 14 14 15 15 15 16 16 16 1003090 en 12 0 Issue 2020 10 09 14 ...

Страница 15: ...Read the value at the bottom of the display 00 Escape function is disabled when the door is locked default 01 Escape function is enabled when the door is locked Real time clock The CDC system has a real time clock built in The clock is used for event log recording and when the door is running according to a real time operation schedule FUNC DATA EAA168 Read real time clock TypeF71 Thedisplayshows1...

Страница 16: ...tandard Description No Pressure sensitive safety edges placed on the drum edges see page 17 1 Force sensitive door leaves see page 17 2 Emergency stop push button see page 17 3 Options Description No Pressure sensitive safety edges placed on the door leaves see page 28 A Infrared presence sensing system see page 28 B Vertical presence photocell sensor PDR see page 29 C Break out kit see page 27 D ...

Страница 17: ...cleared and the door pushed forward during the waiting period operation is resumed Incasetheblockingpersists E30isshownonthePCDandthedoorremainsstationary To resume operation after the obstacle has been removed the error can be cleared by pushing the door forward or pressing C on the PCD ILL 00048 Emergency stop button The door rotation can be stopped by pressing the emergency stop button To reset...

Страница 18: ...ls and weather stripping 1 condition of glazing rubbers 2 3 Check the safety sensors if any If you are unsure of which type of sensor you have please contact your ASSA ABLOY Entrance Systems representative If equipped with break out test that all door leaves can be released and are not mechanically jammed Press Emergency opening button and fold the door leaves Note If the door is placed in an esca...

Страница 19: ...aning should be documented To avoid damages to the profiles the brushes must be vacuum cleaned weekly Do not expose windows doors or profiles to alkalis Both aluminium and glass are sensitive to alkalis Do not clean with high pressure water Operator programme selector and sensor may be damaged and water may enter the profiles Do not use detergents or abrasive additives Do not scrub with materials ...

Страница 20: ... indicates that the signage is re quired by European directives and equivalent national legislation outside the European Union Product label Mandatory A No entry identifying one way traffic Mandatory in GB and US if applicable not included in the product B Supervision of child applied to both sides of the door Mandatory according to national regulations Recommended if the risk analysis shows use b...

Страница 21: ...has been used on page 27 for start up procedure See Emergency stop button on page 17 for start up procedure Check that nothing is jammed beneath the door The motor starts but door will not rotate Unlock the mechanical locks Change the setting of the PCD see Settings and operation PCD on page 9 The door does not close Check that there are no objects in the safety detection zone Check that nothing i...

Страница 22: ... activated Response from the PDR sensor fitted above the opening on the outside 22 Remove obstacle in the detection zone The detection zone of the touchless door leaf sensors activated Responsefromthetouchless door leaf sensors the door rotates slowly 25 Remove obstacle in the detection zone The detection zone of the touchless door leaf sensors activated Responsefromthetouchless door leaf sensors ...

Страница 23: ...ative to learn more about our service offering Minimum maintenance interval of once a year See EN16005 Action Revolutions Part Check Replace 300 000 1 500 000 Motor Check 300 000 Safety devices Check 300 000 Impulse devices Check 3 000 000 Gear box Check Replace 300 000 600 000 Drive belt Check Replace 300 000 600 000 Motor carbon brushes Check minimum once a year Break out function Check minimum ...

Страница 24: ...Windows 3 1 or higher is required to communicate with the door system Make following settings 1 Windows 3 1 3 11 Start terminal under Accessories or 2 Windows 95 98 and Windows XP Start HyperTerminal under Accessories 3 Windows 7 8 and Vista does not include terminal software A free alternative PuTTY can be downloaded from www putty org 4 Make the following settings VT100 8 bits data No parity One...

Страница 25: ...Whereupon the CDC main menu appears Logout Automatic logout occurs ten minutes after the last key press The automatic logout can be inhibited by entering PCD command F561 To log out manually select Logout from the main menu by pressing number key 6 Logout Menu Current Access Level 1 Logout Y N Press Y to logout or N to return to the main menu Main menu CDC Main Menu RD3 4 CDC42 Door Type Ver 1 01 ...

Страница 26: ...ess function key I Key Impulse Select operating mode by pressing corresponding number key Press Enter to confirm changes Press ESC to return to main menu Other information on screen Manually locked The ON OFF switch is in OFF position Key impulse from terminal is disabled Service request The door has been running for 300 000 revolutions Call for service Real time Real time operation is active Pres...

Страница 27: ... If the door is equipped with the break out solution this must be tested minimum once a year Local regulations needs to be followed Reset after the break out function has been used If the escape doors have been opened the display shows S37 or C3 To make it possible to close the escape doors do the following 1 Release the emergency opening button by turning it in the direction of the arrows 2 Close...

Страница 28: ...eaves providessafetyoverthewholeheightofthedoor Ifthesensor detects an obstacle the door stops or reduces speed to 0 5 rpm configurable When the obstacle is removed the rotation starts Laser presence sensing system Installedonthetopofthedoorleaves providessafetyoverthewholeheightofthedoor Ifthesensor detects an obstacle the door stops or reduces speed to 0 5 rpm configurable When the obstacle is r...

Страница 29: ...safety zone approx 25 from the drum edge the door stops When the obstacle is removed the rotation starts Push button for disabled Push button to reduce speed of the door ILL 00050 Push button inside door In case somebody is trapped in a compartment the door can be opened by pushing this button placed inside on the mid post 29 Issue 2020 10 09 1003090 en 12 0 ...

Страница 30: ...e activ ation units The brake can also be activated with a key switch or push button for immediate stop of the door ILL 00052 Electromechanical lock The electromechanical lock locks the door in home position ILL 00051 Direction sensing radar DSR The radar DSR is direction sensing i e it triggers an opening impulse for approaching objects only but not for objects leaving the door 1003090 en 12 0 Is...

Страница 31: ...ption panel ThereceptionpanelcontainsaProgramControlDevice PCD akeyimpulseandanemergencystop button The key impulse makes the door rotate 360º The maximum cable distance from the door to the reception panel is 100 m The reception panel replaces the standard PCD 31 Issue 2020 10 09 1003090 en 12 0 ...

Страница 32: ... FUNC DATA 1 2 4 5 7 8 0 3 6 9 F S C F2 06 FUNC DATA 1 2 4 5 7 8 0 3 6 9 F S C F2 07 FUNC DATA 1 2 4 5 7 8 0 3 6 9 F S C E 30 FUNC DATA 1 2 4 5 7 8 0 3 6 9 F S C E 20 FUNC DATA ILL 02055 1 2 4 5 7 8 0 3 6 9 F S C on FUNC DATA Locked 1 2 4 5 7 8 0 3 6 9 F S C S C3 FUNC DATA C C 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 I N EMERGENC Y PUSH TO OPE N I N EMERGENC Y PUSH TO OPE N E M ERGENCY STOP Acc...

Страница 33: ... doors Dock shelters Air curtains Folding doors Sliding doors High speed doors Swing doors Loadhouses Automatic and manual activation units Overhead sectional doors Service such as preventive maintenance and upgrade programs emergency repairs service advice and door management 33 Issue 2020 10 09 1003090 en 12 0 ...

Страница 34: ... Other standards or technical specifications which have been applied IEC 60335 2 103 ed 2 2006 A1 2010 IEC 60335 1 ed 5 2010 EN 1627 2011 Class RC3 Certificate issued by a notified or competent body for full address please contact ASSA ABLOY Entrance Systems AB concerning the equipment SC0834 14 BY 112 02 01 020 08532 TÜV B 058029 0045 The manufacturing process ensures the compliance of the equipm...

Страница 35: ......

Страница 36: ...AlbanyandMegadoor brands we offer our solutions under the ASSA ABLOY brand Our products and services are dedicated to satisfying end user needs for safe secure convenient and sustainable operations ASSA ABLOY Entrance Systems is a division within ASSA ABLOY assaabloyentrance com ASSA ABLOY Entrance Systems Tel 46 10 47 47 000 info aaes assaabloy com assaabloyentrance com ...

Отзывы: