Re-Fasten

Screws

TOP & BOTTOM 

8-32 X 5/16" 

TRUSS HEAD SCREWS

TOP & 

BOTTOM 

YOKES

BACK of 

STILE WALL

INSIDE of 

STILE WALL

DEPTH

DIM.

TUBE

SPACERS

MOUNTING

PLATE

3/16" 

HEX KEY

DEPTH

DIM.

Lock Prep for Traditional 

Mounting Installations

MEASURE the depth from the back of the 

stile to the inside wall, see 

Diagram 13A

.

MATCH THE DEPTH dimension from 

face of Mounting Plate to the Tube 

spacers. Use 3/16” Hex Key for fine 

adjustment, see 

Diagram 13B

.

Lock Prep for Mounting 

Tab Installations Only

REMOVE top and bottom screws and 

yokes (adjustable mounting tube 

brackets), see 

Diagram 14A

.

RE-FASTEN screws, see 

Diagram 14B

.

DIAGRAM 13A:

DIAGRAM 13B:

DIAGRAM 14A:

DIAGRAM 14B:

of 8

Содержание Adams Rite DL100

Страница 1: ...ow Lock 125 3 2 mm For optimal lock performance the gap between the door and frame must meet industry standard of 1 8 DL100 Wireless Deadlatch Installation Instructions Frame and Door Preparation 1 PR...

Страница 2: ...DER C L C L RADIUS BEVEL C L C L HOW BACKSET IS MEASURED A A A DIAGRAM 6B Door Stiles DIAGRAM 6C Mortise Cylinder Cam Turning Key Handle Paddle DOES NOT pull Main Latch Assy MORTISE CYLINDER CAM DL100...

Страница 3: ...r the holes after drilling See Diagram 8 5 POSITION reader in desired location on door See Diagram 2B 6 Using backplate as a template MARK and DRILL 3X 7 64 DIA holes and 1X 3 8 DIA hole in the door D...

Страница 4: ...URE the depth from the back of the stile to the inside wall see Diagram 13A 2 MATCH THE DEPTH dimension from face of Mounting Plate to the Tube spacers Use 3 16 Hex Key for fine adjustment see Diagram...

Страница 5: ...tral position for flat or radius door stiles Bevel Adjustment 1 ROTATE bevel tab to desired hand position see Diagram 15 2 Bevel adjustment allows flat faceplate to sit flush with beveled door stile R...

Страница 6: ...matic NOTE Verify wire harness is not being contacted by mounting screws Verify Lock Operation 1 INDEPENDENTLY TURN the key or operate the trim to ensure the main latch collapses into the door releasi...

Страница 7: ...0 TEN Red Flashes Error in Lock Continuous Yellow Flashes 25 sec every 5 seconds Low Battery Continuous Red Flashes 25 sec every 5 seconds Dead Battery APERIO LED HUB CODES Steady Green Online Steady...

Страница 8: ...tement This device complies with Industry Canada license exempt RSS standards s Operation is subject to the following two conditions 1 this device may not cause interference and 2 this device must acc...

Отзывы: