English

Bits Per Second

Use this item to select the serial port transmission speed. The speed used in the host 
computer and the client computer must be the same. Long or noisy lines may require lower 
transmission speed. The options include [9600], [19200], [38400], [57600] and [115200].

Data Bits

Use this item to set the data transmission size. The options include [7] and [8] (Bits).

Parity

Use this item to select the parity bit. The options include [None], [Even], [Odd], [Mark] and 
[Space]. A parity bit can be sent with the data bits to detect some transmission errors.Mark 
and Space Parity do not allow for error detection. They can be used as an additional data 
bit.
Even: parity bit is 0 if the num of 1's in the data bits is even.
Odd: parity bit is 0 if num of 1's in the data bits is odd.
Mark: parity bit is always 1. 
Space: Parity bit is always 0. 

Stop Bits

The item indicates the end of a serial data packet. The standard setting is [1] Stop Bit. Select 
[2] Stop Bits for slower devices.

Flow Control

Use this item to set the flow control to prevent data loss from buffer overflow. When 
sending data, if the receiving buffers are full, a "stop" signal can be sent to stop the data 
flow. Once the buffers are empty, a "start" signal can be sent to restart the flow. Hardware 
flow uses two wires to send start/stop signals. The options include [None] and [Hardware 
RTS/CTS].

VT-UTF8 Combo Key Support

Use this item to enable or disable the VT-UTF8 Combo Key Support for ANSI/VT100 
terminals.

Recorder Mode

Use this item to enable or disable Recorder Mode to capture terminal data and send it as 
text messages.

Resolution 100x31

Use this item to enable or disable extended terminal resolution support.

Putty Keypad

Use this item to select Function Key and Keypad on Putty.

Legacy Console Redirection

Legacy Console Redirection Settings

Use this option to configure Legacy Console Redirection Settings, and specify how your 

Содержание D2143D4I2-2T

Страница 1: ...D2143D4I2 2T D2163D4I2 2T User Manual Version 1 0 Published May 2019 Copyright 2019 ASRock Rack INC All rights reserved...

Страница 2: ...mplied including but not limited to the implied warranties or conditions of merchantability or fitness for a particular purpose In no event shall ASRock Rack its directors officers employees or agents...

Страница 3: ...ant to know more about ASRock Rack you re welcome to visit ASRock Rack s website at www ASRockRack com or you may contact your dealer for further information ASRock Rack Incorporation 6F No 37 Sec 2 J...

Страница 4: ...recautions 12 2 3 Installation of Memory Modules DIMM 13 2 4 Expansion Slots PCI Express Slots 15 2 5 Jumper Setup 16 2 6 Onboard Headers and Connectors 17 2 7 Unit Identification purpose LED Switch 2...

Страница 5: ...ation 39 3 3 6 USB Configuration 40 3 3 7 Super IO Configuration 41 3 3 8 Serial Port Console Redirection 42 3 3 9 H W Monitor 46 3 3 10 Runtime Error Logging 48 3 3 11 Instant Flash 50 3 4 Security 5...

Страница 6: ...port CD Information 66 4 2 1 Running The Support CD 66 4 2 2 Drivers Menu 66 4 2 3 Utilities Menu 66 4 2 4 Contact Information 66 Chapter 5 Troubleshooting 67 5 1 Troubleshooting Procedures 67 5 2 Tec...

Страница 7: ...Factor 6 7 in x 6 7 in 17 02 cm x 17 02 cm Quick Installation Guide 1 x Oculink to 4 SATA Cable 60cm 1 x SATA Power Cable 80cm 1 x ATX 4P to 24P Power Cable 1 x I O Shield 2 x Screws for M 2 Sockets I...

Страница 8: ...cy ECC RDIMM 2133 2400 2666 MHz LR DIMM 2133 2400 2666 MHz the max speed may vary based on SoC SKU Expansion Slot PCIe 3 0 x 16 SLOT7 Gen3 x16 link Storage SATA Controller Intel Xeon D 2143 or D 2163...

Страница 9: ...t 1 rear build in CPU active fansink ATX Power 1 x 4 pin 1 x 8 pin support 12V DC IN DC IN mode power budget is up to 432W SATA Power 1 for DC IN mode Caution Misconnection may permanently damage the...

Страница 10: ...ration temperature 10 C 35 C Non operation temperature 40 C 70 C Install a CPU Fan when the airflow through the heatsink is below 2CFM For detailed product information please visit our website http ww...

Страница 11: ...this utility you can press the F6 key during the POST or the F2 key to enter into the BIOS setup menu to access ASRock Rack Instant Flash Just launch this tool and save the new BIOS file to your USB f...

Страница 12: ...88 pin module Blue DDR4 DDR4_D1 DDR4 Blue 64 bit 288 pin module 1 PSU_SMB1 FAN1 BAT1 NUT9 M2_1 PCIE7 1 ME_RECOVERY1 VGA1 USB 3 0 T USB2 B USB1 IPMI LAN UID1 LAN1 LAN2 CLRMOS1 FAN3 ITX_AUX_PANEL1 1 COM...

Страница 13: ...SGPIO Connector SATA_SGPIO1 12 TPM Header TPM1 13 Auxiliary Panel Header ITX_AUX_PANEL1 14 System Panel Header PANEL1 15 ME Recovery Jumper ME_RECOVERY1 16 OCuLink x4 Connector OCU2 17 OCuLink x4 Conn...

Страница 14: ...LED PWRBTN DDR4_C1 64 bit 288 pin module Blue DDR4 DDR4_D1 DDR4 Blue 64 bit 288 pin module 1 PCIE7 1 UID1 1 1 BMC AST2500 RoHS 1 1 2 3 4 5 FAN2 FAN1 FAN3 No Item Status Description 1 LED_FAN2 Amber FA...

Страница 15: ...witch LED UID1 LAN Port LED Indications There are two LED next to the LAN port Please refer to the table below for the LAN port LED indications Dedicated IPMI LAN Port LED Indications Activity Link LE...

Страница 16: ...dications 10G LAN Port LAN3 LAN4 LED Indications Activity Link LED Speed LED Status Description Status Description Off No Link Off 100Mbps connection or no link Blinking Yellow Data Activity Yellow 1G...

Страница 17: ...D2143D4I2 2T D2163D4I2 2T 11 English 1 7 Block Diagram...

Страница 18: ...member to use a grounded wrist strap or touch a safety grounded object before you handle the compo nents 3 Hold components by the edges and do not touch the ICs 4 Whenever you uninstall any component...

Страница 19: ...suggest not using this configuration 1 For dual channel configuration you always need to install identical the same brand speed size and chip type DDR4 DIMM pairs 2 It is not allowed to install a DDR...

Страница 20: ...14 English 1 2 3...

Страница 21: ...power cord is unplugged Please read the documentation of the expansion card and make necessary hardware settings for the card before you start the installation Step 2 Remove the system unit cover if y...

Страница 22: ...laced on the pins the jumper is Short If no jumper cap is placed on the pins the jumper is Open The illustration shows a 3 pin jumper whose pin1 and pin2 are Short when a jumper cap is placed on these...

Страница 23: ...urn off your system using the power switch RESET Reset Switch Connect to the reset switch on the chassis front panel Press the reset switch to restart the computer if the computer freezes and fails to...

Страница 24: ...e TPM system which can securely store keys digital certificates passwords and data A TPM system also helps enhance network security protects digital identities and ensures platform integrity PSU SMBus...

Страница 25: ...3 For more details please refer to the Cooler QVL list on the ASRock Rack website SATA Power Connector DC IN Mode 4 pin ATX12V3 see p 6 No 4 1 2 3 4 5V GND 12V GND Please use a SATA power cable to co...

Страница 26: ...a cabled baseboard or front panel connection for value added features and 3rd party add in cards such as Emergency Management cards that provide management features using the IPMB Serial Port Header...

Страница 27: ...pressed the front rear UID blue LED indicator will be turned on Press the UID button again to turn off the indicator 2 8 Driver Installation Guide To install the drivers to your system please insert t...

Страница 28: ...ndles all non TCP IP traffic The Secondary adapter will receive fallback traffic if the primary fails If the Preferred Primary adapter fails but is later restored to an active status control is automa...

Страница 29: ...ce mPCIe and mSATA The Ultra M 2 Socket supports a M 2 SATA3 6 0 Gb s module or a M 2 PCI Express module up to Gen3 x4 32Gb s Installing the M 2_SSD NGFF Module Step 1 Prepare a M 2_SSD NGFF module an...

Страница 30: ...protective film on the nut to be used Hand tighten the standoff into the desired nut location on the motherboard B A B A 20o Step 5 Align and gently insert the M 2 NGFF SSD module into the M 2 slot P...

Страница 31: ...talling the M 2_SSD NGFF Module Step 1 Prepare a M 2_SSD NGFF module and the screw 20o Step 2 Gently insert the M 2 NGFF SSD module into the M 2 slot Please be aware that the M 2 NGFF SSD module only...

Страница 32: ...of the screen has a menu bar with the following selections Item Description Main To set up the system time date information Advanced To set up the advanced UEFI features Security To set up the securit...

Страница 33: ...ption for the selected items Tab Switch to next function Enter To bring up the selected screen PGUP Go to the previous page PGDN Go to the next page HOME Go to the top of the screen END Go to the bott...

Страница 34: ...2 Main Screen Once you enter the UEFI SETUP UTILITY the Main screen will appear and display the system overview The Main screen provides system overview information and allows you to set the system t...

Страница 35: ...reen In this section you may set the configurations for the following items CPU Configuration DRAM Configuration Chipset Configuration Storage Configuration ACPI Configura tion USB Configuration Super...

Страница 36: ...lity issues with some power supplies Please set this item to Disabled if above issues occur Intel Turbo Boost Technology Intel Turbo Boost Technology enables the processor to run above its base operat...

Страница 37: ...lasses of malicious buffer overflow attacks Enable Intel TXT Support Enables Intel Trusted Execution Technology Configuration Intel Virtualization Technology Intel Virtualization Technology allows a p...

Страница 38: ...are P States Disable Hardware chooses a P state based on OS Request Legacy P States Native Mode Hardware chooses a P state based on OS guidance Out of Band Mode Hardware autonomously chooses a P state...

Страница 39: ...detect the memory module s inserted and assign the appropriate frequency automatically Channel Interleaving Select to configure Channel Interleaving settings Rank Interleaving Select to configure Ran...

Страница 40: ...ics Adapter If PCI Express graphics card is installed on the motherboard you may use this option to select PCI Express or Onboard VGA as the primary graphics adapter If no PCI Express graphics card is...

Страница 41: ...nables or disables the ASPM support for all CPU downstream devices OCU1 Link Speed This allows you to select OCU1Link Speed The default value is Auto OCU1 ASPM Support This option enables or disables...

Страница 42: ...tem has SR IOV capable PCIe Devices this option Enables or Disables Single Root IO Virtualization Support Restore AC Power Loss This allows you to set the power state after a power failure If Power Of...

Страница 43: ...e SATA Controllers SATA Mode Selection Identify the SATA port is connected to Solid State Drive or Hard Disk Drive Press Ctrl I to enter RAID ROM during UEFI POST process SATA ALPM Use this item to en...

Страница 44: ...nter RAID ROM during UEFI POST process sSATA ALPM Use this item to enable or disable Support Aggressive Link Power Management M2_1 sSATA M2_2 sSATA M2_1 PCIE M2_2 PCIE Depending on how many SATA ports...

Страница 45: ...aked up by a PCIE device and enable wake on LAN Ring In Power On Use this item to enable or disable Ring In signals to turn on the system from the powersoft off mode RTC Alarm Power On Allow the syste...

Страница 46: ...Enable or disable Legacy OS Support for USB 2 0 devices If you encounter USB compatibility issues it is recommended to disable legacy USB support Select UEFI Setup Only to support USB devices under th...

Страница 47: ...Port Use this item to enable or disable the serial port COM Change Settings Use this item to select an optimal setting for Super IO device SOL Configuration Use this item to set parameters of SOL Seri...

Страница 48: ...Redirection Settings and specify how your computer and the host computer to which you are connected exchange information Both computers should have the same or compatible settings Terminal Type Use t...

Страница 49: ...top Bits The item indicates the end of a serial data packet The standard setting is 1 Stop Bit Select 2 Stop Bits for slower devices Flow Control Use this item to set the flow control to prevent data...

Страница 50: ...ected exchange information Out of Band Mgmt Port Microsoft Windows Emergency Management Services EMS allows for remote management of a Windows Server OS through a serial port Terminal Type Use this it...

Страница 51: ...D2143D4I2 2T D2163D4I2 2T 45 English CTS and Software Xon Xoff Data Bits Parity Stop Bits...

Страница 52: ...l controlled by BMC If Manual is selected configure the items below FAN1 This allows you to set the CPU fan1 s speed The default value is Smart Fan FAN2 This allows you to set the rear fan1 s speed Th...

Страница 53: ...47 English Smart Fan Temp Control Smart Fan Temp x x means 1 to 11 stage This allows you to set temperature for each stage Watch Dog Timer This allows you to enable or disable the Watch Dog Timer The...

Страница 54: ...s S W Error Injection Support When it is set to Enabled S W Error Injection is supported by unlocking MSR Ox790 Memory Error Memory enabling and logging setup option Correctable Error Threshold Correc...

Страница 55: ...143D4I2 2T D2163D4I2 2T 49 English PCIE Uncorrected Error Enable Use this item to enable or disable PCIe Uncorrectable errors PCIE Fatal Error Enable Use this item to enable or disable PCIe Fatal erro...

Страница 56: ...isk or hard drive and launch this tool then you can update your UEFI only in a few clicks without preparing an additional floppy diskette or other compli cated flash utility Please be noted that the U...

Страница 57: ...press enter to remove the password User Password Set or change the password for the user account Users are unable to change the settings in the UEFI Setup Utility Leave it blank and press enter to rem...

Страница 58: ...re Boot Keys Please install default secure boot keys if it s the first time you use secure boot Clear Secure Boot keys Force System to Setup Mode clear all Secure Boot Variables Change takes effect af...

Страница 59: ...URE_LIST b EFI_CERT_X509 DER c EFI_CERT_RSA2048 bin d EFI_CERT_SHA256 384 512 2 Authenticated UEFI Variable 3 EFI PE COFF Image SHA256 Key Source Factory External Mixed Key Exchange Keys Enroll Factor...

Страница 60: ...s from a file 1 Public Key Certificate in a EFI_SIGNATURE_LIST b EFI_CERT_X509 DER encoded c EFI_CERT_RSA2048 bin d EFI_CERT_SHA256 384 512 2 Authenticated UEFI Variable 3 EFI PE COFF Image SHA256 Key...

Страница 61: ...natures Enroll Factory Defaults or load certificates from a file 1 Public Key Certificate in a EFI_SIGNATURE_LIST b EFI_CERT_X509 DER encoded c EFI_CERT_RSA2048 bin d EFI_CERT_SHA256 384 512 2 Authent...

Страница 62: ...to set the system boot order Boot Option 2 Use this item to set the system boot order Boot Option 3 Use this item to set the system boot order Boot Option Filter This option controls Legacy UEFI ROMs...

Страница 63: ...er the Boot Beep should be turned on or off when the system boots up Please note that a buzzer is needed Full Screen Logo Enable to display the boot logo or disable to show normal POST messages AddOn...

Страница 64: ...tion ROM only Select Legacy only to run those that support legacy option ROM only Select Do not launch to not execute both legacy and UEFI option ROM Launch Video OpROM Policy Select UEFI only to run...

Страница 65: ...the default is Disabled with NVMe device but it is Legacy with other devices This item can t select Video Option ROM policy OCU2 Slot OpROM Use this item to select slot storage and Network Option ROM...

Страница 66: ...Event Log The options include No Yes Next reset and Yes Every reset If Yes is selected all logged events will be erased When Log is Full Use this item to choose options for reactions to a full Smbios...

Страница 67: ...response for specified time out BMC starts at the same time when BIOS starts during AC power ON It takes around 90 seconds to initialize Host to BMC interfaces Inventory Support This will execute inve...

Страница 68: ...g for error progress codes during boot Erase SEL Use this to choose options for earsing SEL When SEL is Full Use this to choose options for reactions to a full SEL Log EFI Status Codes Use this item t...

Страница 69: ...ed by DHCP If you prefer using a static IP address toggle to Yes and the changes take effect after the system reboots The default value is No Configuration Address Source Select to configure BMC netwo...

Страница 70: ...ace is Username admin Password admin For more instructions on how to set up remote control environment and use the IPMI man agement platform please refer to the IPMI Configuration User Guide or go to...

Страница 71: ...following message Discard changes and exit setup will pop out Press ESC key or select Yes to exit the UEFI SETUP UTILITY without saving any changes Discard Changes When you select this option the foll...

Страница 72: ...matically displays the Main Menu if AUTORUN is enabled in your computer If the Main Menu does not appear automatically locate and double click on the file ASRSetup exe from the root folder in the Supp...

Страница 73: ...et to default settings 3 Check the settings of the 115V 230V switch on the power supply 4 Verify if the battery on the motherboard provides 3VDC Install a new battery if it does not If there is no vid...

Страница 74: ...battery on the motherboard provides 3VDC Install a new battery if it does not 2 Confirm whether your power supply provides adaquate and stable power Other problems 1 Try searching keywords related to...

Страница 75: ...t or a copy of your invoice marked with the date of purchase is required By calling your vendor or going to our RMA website http event asrockrack com tsd asp you may obtain a Returned Merchandise Auth...

Отзывы: