background image

2

3

English

1.1  Shipping Box Contents

* The components are pre-installed.

** Please purchase seperately if needed. You may need this optional accessory when the power connectors 
of your GPGPU card are on the top side of it.

If any items are missing or appear damaged, contact your authorized dealer.

Item

Quantity

3U8G Series Barebone (3U form factor)

1

System Boards (MB)*

1

Power Supply Units*

4

System Fans*

8

HDD Backplane (BPB)*

1

Front Panel Board*

1

Power Distribution Boards (PDB)*

1

Switch Board  (SWB)*

1

Power Cable, ATX 24Pin, PDB to MB, 520mm*

1

Power Cable, ATX 8Pin-1, PDB to MB, 470mm*

1

Power Cable, ATX 8Pin-2, PDB to MB, 500mm*

1

PMBus Cable, PDB to MB(1*5Pin), 470mm*

1

3U Front Control Cable (1 to 4 connectors)*

1

3U USB Cable 9Pin, 850mm*

1

MiniSAS Cable, 380mm (SATA0-3)*

1

SATA Cable, 310mm (SATA4 / SATA5)*

2

BPB Power Cable, PDB to HDD BPB*

2

3U MNG Cable, Pitch 2.0 1*5P, 610mm*

1

GPGPU Power Cable*

8

Accessory Box

1

Support CD

1

User Manual

1

Quick Installation Guide

1

4U Top Cover (Optional)**

1

3U8G_RB(Optional)

1

3U8G_MCB(Optional)

1

Содержание BAREBONE 3U8G SERIES

Страница 1: ......

Страница 2: ...implied including but not limited to the implied warranties or conditions of merchantability or fitness for a particular purpose In no event shall ASRock Rack its directors officers employees or agent...

Страница 3: ...en removal of the chassis lid required for servicing Turn off power and unplug any power cords cables and Reinstall the chassis lid before restoring power Important Safety Instructions Pay close atten...

Страница 4: ...nel 8 2 5 Front Control Panel Buttons and LEDs 9 2 6 PSU LED 11 2 7 Drive Tray LEDs 11 2 8 Fan Failed LED 12 Chapter 3 Hardware Installation and Maintenance 13 3 1 Server Top Cover 14 3 2 Hard Drive 1...

Страница 5: ...Installing the CPU Fan and Heatsink 45 Installation of Memory Modules DIMM 46 Appendix B 47 Installing the Server in a Rack 47...

Страница 6: ......

Страница 7: ...ecifications might be updated the content of this documentation will be subject to change without notice In case any modifications of this documentation occur the updated version will be available on...

Страница 8: ...Backplane BPB 1 Front Panel Board 1 Power Distribution Boards PDB 1 Switch Board SWB 1 Power Cable ATX 24Pin PDB to MB 520mm 1 Power Cable ATX 8Pin 1 PDB to MB 470mm 1 Power Cable ATX 8Pin 2 PDB to MB...

Страница 9: ...tivity LED 4 x Network activity LEDs System event LED I O Ports 2 x USB 2 0 ports Drive Bay External 6 x 2 5 SATA HDDs 6Gb s System Cooling Fan 8 x 80 38 mm system fans Power Supply Capacity 4 3 1 Red...

Страница 10: ...apter provides diagrams showing the location of important components of the server system 2 1 System Components 6 x 2 5 Hot Swap HDD Trays Server Board Power Supply Units 8 x Hot Swap System Fans 8 x...

Страница 11: ...3U8G Series 5 English 2 2 Internal Features 10 11 12 13 14 15 16 17 5 1 6 18 8 7 19 20 21 22 23 24 25 9 2 3 4...

Страница 12: ...oard BPB 8 Power Distribution Board PDB 9 Switch Board SWB 10 System Fan 2 11 System Fan 4 12 System Fan 6 13 System Fan 8 14 System Fan 1 15 System Fan 3 16 System Fan 5 17 System Fan 7 18 GPGPU MIC...

Страница 13: ...3U8G Series 7 English 2 3 System Front Panel 2 1 3 No Description 1 Control Panel Buttons and LEDs 2 2 x USB 2 0 Ports 3 8 x GPGPU MIC Card Slots...

Страница 14: ...3 Mezzanine Card Support for 1GbE x 2 or 10GbE x2 Only supported for 3U8G C612 4 Low Profile PCI Express Slot for the riser card Only supported for 3U8G C612 V 5 Motherboard Tray Handle WARNING Pleas...

Страница 15: ...t Button 7 System Reset Button Please be noted that the functions are supported depending on the type of the server board Power Button Press the power switch button to toggle the system power on and s...

Страница 16: ...and initialize the system Status LED Definitions Power LED Status Description Green Power on Off Power off ID LED Status Description Blue System identification is active Off System identification is d...

Страница 17: ...OVP Fan Fail OTP UVP AC cord unplugged Amber blinking at 0 5Hz Warning high temp high power high current slow fan Green blinking at 0 5Hz AC Present Only 12VSB on PS off or PS in Smart Redundant stat...

Страница 18: ...vity LED Status Description Solid Green HDD active Blinking Green HDD accessing or reading Red HDD failed Off HDD powered off 2 8 Fan Failed LED Fan Failed LED Fan LED Status Description Solid Red Fan...

Страница 19: ...any system component A discharge of static electricity may damage components Wear a grounded wrist strap if available Installing Procedures The followings are prerequisite to be installed 2 5 HDD s Po...

Страница 20: ...covers Chapter 3 5 p 28 CPU DIMM A middle and C rear covers Appendix A p 38 A Top Middle Cover 1 1 1 2 1 Remove the eight screws that secure the top middle cover to the chassis 2 Lift up and remove th...

Страница 21: ...ews that secure the top front or rear cover to the chassis 2 Push the top front cover or the top rear cover toward the FRONT of the chassis to remove the cover from the locked position 3 Lift up and r...

Страница 22: ...outs 2 Slide the top front or rear cover toward the REAR of the chassis Use a 4U top front cover instead if the power connectors of your GPGPU card are on the top side of it Please purchase seperately...

Страница 23: ...both top front and rear covers are properly secured lower the top middle cover on the chassis Carefully align the mounting holes in the top middle cover and the chassis 5 Secure the top middle cover...

Страница 24: ...ot swappable 2 5 hard drives Six 2 5 hard drive trays are located on the rear of the chassis Removing 2 5 Hard Drive Trays from the Chassis 1 Press the locking lever latch on the drive tray to unlock...

Страница 25: ...ray with the printed circuit board side facing down Carefully align the mounting holes in the hard drive and the tray 2 Secure the hard drive using the two screws 3 Slide the drive tray into the HDD b...

Страница 26: ...r full load operation with the fourth power supply purely as a redundant load sharing backup It can be removed without affecting system operation 1 Align the power supply unit with the power supply sl...

Страница 27: ...e PSU 1 Hold onto the power supply handle while pressing the locking lever towards the power supply handle 2 Pull to remove the power supply from the chassis 1 1 1 2 1 Before replacing the power suppl...

Страница 28: ...p middle cover from the chassis See p 14 for more details 2 Lift to remove the failed fan 3 Align the mounting holes on the replacement fan corners with the fan mounts on the fan bracket Make sure the...

Страница 29: ...e fans on the cards the system requires back to front air flow routing so you need to reverse the fan modules before installing the system fans Be sure to completely power down the system before rever...

Страница 30: ...24 English To reverse fan modules please follow the steps below 1 Gently lift and remove the fans A from the front row and the fans B from the rear row FRONT REAR A B...

Страница 31: ...Series 25 English 2 Turn all the four fan modules A 180 degrees around Place them to the rear row 3 Turn all the four fan modules B 180 degrees around Place them to the front row 180 180 A B B A FRONT...

Страница 32: ...more instructions on how to remove and install a GPGPU card please refer to the section entitled 3 5 GPG or MIC Card 6 Move the jumper caps placed on the FAN Flow Switch Jumper FAN_FLOW_SW1 from pins...

Страница 33: ...N Flow Switch Jumper 3 pin FAN_FLOW_SW1 For Passive Card Front to back air flow Default For Active Card Back to front air flow 7 Place the GPGPU Card back into the Slot 8 Put the top front cover back...

Страница 34: ...or MIC Card Installing and Removing the GPU or MIC Card 1 Release the screw of the GPU MIC card slot on the front of the chassis 2 Pull down the retention lever 3 Release the screw that secures the bl...

Страница 35: ...3U8G Series 29 English 4 4 Lift to remove the blanking plate...

Страница 36: ...the back of the GPU MIC card or on the side of the card If the power connectors of the GPGPU card you use are on the top side the connectors and the connected cable will extend the height of the card...

Страница 37: ...3U8G Series 31 English 6 6 Gently place the GPU or MIC card into the empty slot Make sure the card is well seated...

Страница 38: ...32 English 8 7 7 Pull up the retention lever 8 Hand tighten the screw to secure the inserted GPU MIC card...

Страница 39: ...d tray 2 Press the locking tab in the middle to release the handles Release Handles 1 Locking Tab 2 3 Rotate and open the release handles on the sides of the motherboard tray to disengage the tray fro...

Страница 40: ...34 English 4 Then you can grasp the handles and slide the tray all the way out of the chassis 4...

Страница 41: ...ine on the tray almost reaches the edge of the chassis 2 Make sure the black line on the top edge of the tray is evenly aligned with the edge of the chassis 3 Then close the release handles completely...

Страница 42: ...card power off the server and unplug the power cord Please be noted that add on card is supported for certain models only Please check the rear panel of your chassis and see if a low profile PCI Expre...

Страница 43: ...ease refer to the followings for instructions 1 Peel off the adhesive backing on the bottom side of the air baffle Gently attach the air baffle onto the low profile passive heatsink 1 Air Baffle Low P...

Страница 44: ...add on card such as a graphics card to the riser card 4 5 Align the plate of the add on card with the openings in the back of the chassis Attach the add on card to the chassis with the screw that was...

Страница 45: ...3U8G Series 39 English Appendix A Installing the CPU Socket LGA2011 R3 A B A B 1 2 3...

Страница 46: ...40 English B A 4 5 6...

Страница 47: ...3U8G Series 41 English The cover must be placed if returning the motherboard for after service A B 7 8 9 B C A A B...

Страница 48: ...42 English Installing the CPU Socket LGA2011 A B A B 1 2 3...

Страница 49: ...3U8G Series 43 English B A 4 5 6...

Страница 50: ...44 English The cover must be placed if returning the motherboard for after service A B A B 7 8 9 B C A...

Страница 51: ...ish Installing the CPU Fan and Heatsink Passive heatsink for narrow ILM socket Before you installed the heatsink you need to spray thermal interface material between the CPU and the heatsink to improv...

Страница 52: ...ne correct orientation It will cause permanent damage to the motherboard and the DIMM if you force the DIMM into the slot at incorrect orientation For more information about DIMM installation please r...

Страница 53: ...rack Slide Rail Chassis Rail Removing the Chassis Rail from the Slide Rail Assembly 1 Pull out the inner chassis rail from the rail assembly 2 Push the white chassis rail release button toward the fro...

Страница 54: ...ard the front of the chassis until the chassis rail clips Make sure the rail is installed in the correct direction 3 Secure the chassis rail to the server chassis with screws 4 Repeat for the remainin...

Страница 55: ...ee space above the slide rail bracket are required If you use a 4U top cover for the server you need to have 9 holes of free space above the slide rail bracket For the rack with square mounting holes...

Страница 56: ...lish 2 Extend the pre attached front and rear adjustable brackets on the slide Do not fully tighten the nuts yet Front Bracket Rear Bracket 3 Adjust the brackets to accommodate the depth of the rack 1...

Страница 57: ...ackets with the mounting holes you selected on the rack 5 Tighten the screws to secure the slide rails to the rack Make sure the rear bracket meets the rear vertical rail of the rack 11U 12U 6 Fully t...

Страница 58: ...ached to the rack 2 Fully extend the slide rails from the rack by pulling the inner rails out until they are locked and cannot be pulled out further 11U 12U To slide an inner rail back into the slide...

Страница 59: ...the server slowly and evenly all the way into the cabinet to ensure that the slide assemblies are working correctly The server is heavy For safe lifting two or more persons are required to install the...

Страница 60: ...reverse these instructions When connecting cables to the server make sure there is enough cable slack so you can slide the server in and out of the rack without accidentally unplugging a cable Optiona...