Enable wake up event occurs.

Power Policy

Select the Power Policy mode.

Thunderbolt Support

Enable Thunderbolt Support.

Zero-Power ODD

Enable/Disable Zero-Power ODD Feature.

Содержание B550D4M

Страница 1: ...B550D4M User Manual Version 1 0 Published February 2022 Copyright 2022 ASRock Rack INC All rights reserved ...

Страница 2: ...r implied including but not limited to the implied warranties or conditions of merchantability or fitness for a particular purpose In no event shall ASRock Rack its directors officers employees or agents be liable for any indirect special incidental or consequential damages including damages for loss of profits loss of business loss of data interruption of business and the like even if ASRock Rack...

Страница 3: ...RockRack com or you may contact your dealer for further information ASRock Rack Incorporation 6F No 37 Sec 2 Jhongyang S Rd Beitou District Taipei City 112 Taiwan R O C The terms HDMI and HDMI High Definition Multimedia Interface and the HDMI logo are trademarks or registered trademarks of HDMI Licensing LLC in the United States and other countries ...

Страница 4: ... 15 2 2 Pre installation Precautions 15 2 3 Installing the CPU 16 2 4 Installing the CPU Fan and Heatsink 18 2 5 Installing Memory Modules DIMM 21 2 6 Expansion Slots PCI Express Slots 23 2 7 Jumper Setup 24 2 8 Onboard Headers and Connectors 25 2 9 Dr Debug 31 2 10 Unit Identification purpose LED Switch 37 2 11 Driver Installation Guide 37 2 12 M 2 SSD Module Installation Guide 38 Chapter 3 UEFI ...

Страница 5: ...tion 48 3 3 6 USB Configuration 49 3 3 7 Super IO Configuration 50 3 3 8 Serial Port Console Redirection 52 3 3 9 H W Monitor 55 3 3 10 Network Stack Configuration 56 3 3 11 RAM Disk Configuration 58 3 3 12 Tls Auth Configuration 59 3 3 13 AMD PBS 60 3 3 14 AMD Overclocking 63 3 3 15 AMD CBS 64 3 3 16 iSCSI Configuration 65 3 3 17 Instant Flash 66 3 4 Server Mgmt 67 3 4 1 System Event Log 68 3 4 2...

Страница 6: ...4 Software Support 81 4 1 Install Operating System 81 4 2 Support CD Information 81 4 2 1 Running The Support CD 81 4 2 2 Drivers Menu 81 4 2 3 Utilities Menu 81 4 2 4 Contact Information 81 Chapter 5 Troubleshooting 82 5 1 Troubleshooting Procedures 82 5 2 Technical Support Procedures 84 5 3 Returning Merchandise for Service 84 ...

Страница 7: ...herboard ATX Form Factor 9 6 in x 12 in 24 4 cm x 30 5 cm Quick Installation Guide 1 x I O Shield 1 x Screw for M 2 Socket If any items are missing or appear damaged contact your authorized dealer Because the motherboard specifications and the BIOS software might be updated the con tent of this manual will be subject to change without notice In case any modifications of this manual occur the updat...

Страница 8: ...MM Type Dual Channel DDR4 memory technology Support DDR4 ECC Non ECC UDIMM For AMD Ryzen Desktop Processors with Radeon Graphics ECC support is only with Processors with PRO technologies DIMM Size Per DIMM ECC Non ECC UDIMM 32GB 16GB 8GB DIMM Frequency ECC Non ECC UDIMM 3200 2933 2666 2400 2133 MHz Voltage 1 2V Expansion Slot PCIe 4 0 3 0 x 16 Vermeer Matisse PCIE6 Gen4 x8 link CPU Cezanne Renoir ...

Страница 9: ...r is in use there will be no signal on the rear VGA port Serial port 1 x COM port USB 3 2 Gen1 Port 2 5Gbps USB 3 2 Gen2 Port 2 10Gbps LAN Port 2 1 x RJ45 Gigabit Ethernet LAN port LAN Ports with LED ACT LINK LED and SPEED LED HDMI 1 4 1 UID Switch 1 UID LED 1 Internal Connector Auxiliary Panel Header 1 includes chassis intrusion and front LAN LED Front Panel 1 TPM Header 1 17 pin LPC TPM SPI Head...

Страница 10: ...Adjust by CPU Temperature Fan Multi Speed Control Voltage Voltage Monitoring 3VSB 5VSB VCPU VSOC VCCM APU VDDP 1 05V_PROM_S5 2 5V_PROM 1 05V_PROM_RUN BAT 3V 5V 12V Support OS OS Microsoft Windows Windows 10 64 bit Windows 11 64 bit Linux CentOs 8 4 64 bit Ubuntu 21 04 64 bit 18 04 5 64 bit Hypervisor VMWare ESXi 7 0 U2a vSphere 7 0 U2b On the Windows system the RAID mode supports UEFI Boot only Th...

Страница 11: ...ager Intel Ethernet Connection Power Management And the PCI Devices Power On is enabled in UEFI SETUP UTILITY Advanced ACPI Configuration After that onboard LAN can wake up S5 under OS If you install Intel LAN utility or Marvell SATA utility this motherboard may fail Win dows Hardware Quality Lab WHQL certification tests If you install the drivers only it will pass the WHQL tests ...

Страница 12: ...ity you can press the F6 key during the POST or the F2 key to enter into the BIOS setup menu to access ASRock Rack Instant Flash Just launch this tool and save the new BIOS file to your USB flash drive floppy disk or hard drive then you can update your BIOS only in a few clicks without preparing an additional floppy diskette or other complicated flash utility Please be noted that the USB flash dri...

Страница 13: ...AUX_PANEL1 HDLED RESET PLED PWRBTN PANEL1 1 1 TPM1 BUZZER1 RoHS 2 3 1 6 9 10 12 14 15 16 17 18 24 13 29 31 7 8 FAN1 1 FRNT_VGA1 FAN2 ATX12V2 FAN5 FAN3 FAN6 FAN4 USB_1_2 1 USB3_7 1 SPEAKER1 COM2 1 Dr Debug 1 T 1 R 35 AMD B550 BIOS ROM 1 TPM_BIOS_PH1 1 20 21 28 USB 3 2 Gen2 T USB3_4 B USB3_3 LAN1 COM1 LAN2 HDMI1 NUT110_2 M2_2 SATA_5 SATA_6 23 1 IPMB1 BMC_SMB1 NUT80_2 NUT42_2 BMC ROM PSU_SMB1 UID1 4 ...

Страница 14: ...tem Fan Connector FAN5 14 ATX 4 Pin Power Connector ATX12V2 15 System Fan Connector FAN6 16 System Fan Connector FAN4 17 USB 3 2 Gen1 Header USB3_5_6 18 System Panel Header PANEL1 19 Auxiliary Panel Header AUX_PANEL1 20 USB 2 0 Header USB_1_2 21 Vertical Type A USB 3 2 Gen1 USB3_7 22 SATA3 Connector SATA_6 23 SATA3 Connector SATA_5 24 TPM Header TPM1 25 Clear CMOS Pad CLRCMOS1 26 Intelligent Platf...

Страница 15: ...sse 3 0 Cezanne Renoir x16 Slot PCIE6 35 TPM SPI Header TPM_BIOS_PH1 36 Mezzanine Slot MEZZ_A1 If the FRNT_VGA1 header is in use there will be no signal on the rear VGA port For DIMM installation and configuration instructions please see p 20 Installation of Memory Modules DIMM for more details ...

Страница 16: ... LED Indicators 1 1 2 3 4 5 6 7 8 1 B550D4M AMD B550 ATXPWR1 DDR4_A2 64 bit 288 pin module DDR4_A1 64 bit 288 pin module DDR4_B2 64 bit 288 pin module DDR4_B1 64 bit 288 pin moule Socket AM4 PGA 1331 FAN2 1 SATA_3 SATA_4 1 9 ...

Страница 17: ...ED1 Amber FAN1 failed 2 SB_PWR1 Green STB PWR ready 3 FAN_LED2 Amber FAN2 failed 4 FAN_LED3 Amber FAN3 failed 5 FAN_LED5 Amber FAN5 failed 6 FAN_LED6 Amber FAN6 failed 7 FAN_LED4 Amber FAN4 failed 8 BMC_LED1 Green BMC heartbeat LED 9 UID_LED1 Blue UID LED ...

Страница 18: ...is in use there will be no signal on the rear VGA port The HDMI1 port is only supported with APU Cezanne Renoir is installed LAN Port LED Indications There are two LED next to the LAN port Please refer to the table below for the LAN port LED indications Dedicated IPMI LAN Port LED Indications Activity Link LED Speed LED Status Description Status Description Off No Link Off 10M bps connection or no...

Страница 19: ...he table below for the LAN port LED indications LAN Port LED Indications Activity Link LED Speed LED Status Description Status Description Off No Link Off 10Mbps connection or no link Blinking Orange Data Activity Yellow 100Mbps connection On Link Green 1Gbps connection ACT LINK LED SPEED LED LAN Port ...

Страница 20: ...GEN1 USB2 0 USB TYPE A USB TYPE A ECC nonECC UDIMM PCIE GEN4 x8 AMD PROCESSOR Socket AM4 PGA 1331 Support Max 105 W DDR4 DRAM LPC PCIE USB VIDEO DAC AST2500 PCIE SLOT6 SPI FLASH 512Mb SIO NCT6796D R USB TYPE A HDMI GIGA LAN2 OCP MEZZ CONN TYPE A D SUB USB TYPE A USB 3 2 GEN1 HEADER SATA M 2_2 IPMI LAN USB TYPE A B550 FAN 6PIN x6 COM CONNECTOR BIOS SPI FLASH 32MB USB 2 0 Header 2PORT COM HEADER LPC...

Страница 21: ...on Precautions Take note of the following precautions before you install motherboard components or change any motherboard settings 1 Unplug the power cord from the wall socket before touching any components 2 To avoid damaging the motherboard s components due to static electricity NEVER place your motherboard directly on the carpet or the like Also remember to use a grounded wrist strap or touch a...

Страница 22: ...16 English 2 3 Installing the CPU Unplug all power cables before installing the CPU 2 1 ...

Страница 23: ...B550D4M 17 English 3 ...

Страница 24: ...ed to spray thermal grease between the CPU and the heatsink to improve heat dissipation Make sure that the CPU and the heatsink are securely fastened and in good contact with each other Installing the CPU Box Cooler SR1 Please turn off the power or remove the power cord before changing a CPU or heatsink Please be aware of the maximum dimensions of the heatsink to be used is 116 83 65mm 1 ...

Страница 25: ...B550D4M 19 English 2 3 ...

Страница 26: ...20 English 4 ...

Страница 27: ...type DDR4 DIMM pairs 2 It is unable to activate Dual Channel Memory Technology with only one or three memory module installed 3 It is not allowed to install a DDR DDR2 or DDR3 memory module into a DDR4 slot otherwise this motherboard and DIMM may be damaged UDIMM Memory Slot Matisse Renoir Vermeer Cezanne A2 A1 B2 B1 Freq Mhz Freq Mhz Freq Mhz Freq Mhz SR 3200 3200 3200 3200 DR 3200 3200 3200 3200...

Страница 28: ...22 English The DIMM only fits in one correct orientation It will cause permanent damage to the motherboard and the DIMM if you force the DIMM into the slot at incorrect orientation 1 2 3 ...

Страница 29: ...eration Mechanical Electrical Source PCIE6 3 0 x16 x8 CPU PCIE4 3 0 x8 x4 CPU Installing an expansion card Step 1 Before installing an expansion card please make sure that the power supply is switched off or the power cord is unplugged Please read the documentation of the expansion card and make necessary hardware settings for the card before you start the installation Step 2 Remove the system uni...

Страница 30: ...e pins the jumper is Short If no jumper cap is placed on the pins the jumper is Open The illustration shows a 3 pin jumper whose pin1 and pin2 are Short when a jumper cap is placed on these 2 pins NCSI Mode Jumper 3 pin NCSI_SEL1 see p 7 No 33 NCSI is set to onboard LAN1 Default NCSI is set to Mezzanine Card ...

Страница 31: ...rmal restart PLED System Power LED Connect to the power status indicator on the chassis front panel The LED is on when the system is operating The LED is off when the system is in S4 sleep state or powered off S5 HDLED Hard Drive Activity LED Connect to the hard drive activity LED on the chassis front panel The LED is on when the hard drive is reading or writing data The front panel design may dif...

Страница 32: ...se two 2 pin headers allow you to use the Gigabit internet indicator cable to connect to the LAN status indicator When this indicator flickers it means that the internet is prop erly connected C Chassis intrusion pin 2 pin CHASSIS This header is provided for host computer chassis with chassis intrusion detection designs In addition it must also work with external detection equipment such as a chas...

Страница 33: ...t USB 3 2 Gen1 ports on the I O panel there is one USB 3 2 Gen1 header on this motherboard This USB 3 2 Gen1 header can support two USB 3 2 Gen1 ports USB 3 2 Gen1 Connector USB3_7 see p 7 No 21 USB 2 0 Header 9 pin USB_1_2 see p 7 No 20 DUMMY GND GND P P USB_PWR P P USB_PWR 1 There is one USB 2 0 header on this motherboard Each USB 2 0 header can support two ports SATA_2 SATA_1 SATA_4 SATA_3 SATA...

Страница 34: ...V 12V 3V 12 1 13 24 3V 12V GND PSON GND GND GND 5V 5V 5V GND N A This motherboard provides a 24 pin ATX power connector To use a 20 pin ATX power supply please plug it along Pin 1 and Pin 13 ATX 12V Power Connectors 8 pin ATX12V1 see p 7 No 3 4 pin ATX12V2 see p 7 No 14 4 8 1 5 12V GND 1 2 3 4 GND 12V This motherboard provides one 8 pin and one 4 pin ATX 12V power connectors TPM Header 17 pin TPM1...

Страница 35: ... TTXD1 DDCD 1 1 RRI 1 This COM header supports a serial port module TPM SPI Header 13 pin TPM_BIOS_PH1 see p 7 No 35 SPI_WP SPI_CS MISO RSMRST TPM_CS SPI PIRQ SPI_RST MOSI SPI_CLK 3 3V GND SPI_HOLD X 1 This connector supports Trusted Platform Module TPM system for SPI interface which can securely store keys digital certificates passwords and data A TPM system also helps enhance network security pr...

Страница 36: ... management features using the IPMB Baseboard Management Controller SMBus Header 5 pin BMC_SMB1 see p 7 No 27 BMC_SMB_PRESENT_1_N Power BMC_SMBCLK GND BMC_SMBDATA The header is used for the SM BUS devices PSU SMBus Header PSU_SMB1 see p 7 No 5 3V 1 GND ALERT SMBCLK SMBDATA PSU SMBus monitors the status of the power supply fan and system temperature Clear CMOS Pads CLRCMOS1 see p 7 No 25 This allow...

Страница 37: ... codes Code Description 0x10 PEI_CORE_STARTED 0x11 PEI_CAR_CPU_INIT 0x15 PEI_CAR_NB_INIT 0x19 PEI_CAR_SB_INIT 0x31 PEI_MEMORY_INSTALLED 0x32 PEI_CPU_INIT 0x33 PEI_CPU_CACHE_INIT 0x34 PEI_CPU_AP_INIT 0x35 PEI_CPU_BSP_SELECT 0x36 PEI_CPU_SMM_INIT 0x37 PEI_MEM_NB_INIT 0x3B PEI_MEM_SB_INIT 0x4F PEI_DXE_IPL_STARTED 0x60 DXE_CORE_STARTED 0x61 DXE_NVRAM_INIT 0x62 DXE_SBRUN_INIT ...

Страница 38: ..._SB_SMM_INIT 0x72 DXE_SB_DEVICES_INIT 0x78 DXE_ACPI_INIT 0x79 DXE_CSM_INIT 0x90 DXE_BDS_STARTED 0x91 DXE_BDS_CONNECT_DRIVERS 0x92 DXE_PCI_BUS_BEGIN 0x93 DXE_PCI_BUS_HPC_INIT 0x94 DXE_PCI_BUS_ENUM 0x95 DXE_PCI_BUS_REQUEST_RESOURCES 0x96 DXE_PCI_BUS_ASSIGN_RESOURCES 0x97 DXE_CON_OUT_CONNECT 0x98 DXE_CON_IN_CONNECT ...

Страница 39: ... DXE_USB_ENABLE 0xA0 DXE_IDE_BEGIN 0xA1 DXE_IDE_RESET 0xA2 DXE_IDE_DETECT 0xA3 DXE_IDE_ENABLE 0xA4 DXE_SCSI_BEGIN 0xA5 DXE_SCSI_RESET 0xA6 DXE_SCSI_DETECT 0xA7 DXE_SCSI_ENABLE 0xA8 DXE_SETUP_VERIFYING_PASSWORD 0xA9 DXE_SETUP_START 0xAB DXE_SETUP_INPUT_WAIT 0xAD DXE_READY_TO_BOOT 0xAE DXE_LEGACY_BOOT ...

Страница 40: ...OM_INIT 0xB3 DXE_RESET_SYSTEM 0xB4 DXE_USB_HOTPLUG 0xB5 DXE_PCI_BUS_HOTPLUG 0xB6 DXE_NVRAM_CLEANUP 0xB7 DXE_CONFIGURATION_RESET 0xF0 PEI_RECOVERY_AUTO 0xF1 PEI_RECOVERY_USER 0xF2 PEI_RECOVERY_STARTED 0xF3 PEI_RECOVERY_CAPSULE_FOUND 0xF4 PEI_RECOVERY_CAPSULE_LOADED 0xE0 PEI_S3_STARTED 0xE1 PEI_S3_BOOT_SCRIPT 0xE2 PEI_S3_VIDEO_REPOST ...

Страница 41: ...LED 0x57 PEI_CPU_MISMATCH 0x58 PEI_CPU_SELF_TEST_FAILED 0x59 PEI_CPU_NO_MICROCODE 0x5A PEI_CPU_ERROR 0x5B PEI_RESET_NOT_AVAILABLE 0xD0 DXE_CPU_ERROR 0xD1 DXE_NB_ERROR 0xD2 DXE_SB_ERROR 0xD3 DXE_ARCH_PROTOCOL_NOT_AVAILABLE 0xD4 DXE_PCI_BUS_OUT_OF_RESOURCES 0xD5 DXE_LEGACY_OPROM_NO_SPACE 0xD6 DXE_NO_CON_OUT 0xD7 DXE_NO_CON_IN ...

Страница 42: ...0xD9 DXE_BOOT_OPTION_LOAD_ERROR 0xDA DXE_BOOT_OPTION_FAILED 0xDB DXE_FLASH_UPDATE_FAILED 0xDC DXE_RESET_NOT_AVAILABLE 0xE8 PEI_MEMORY_S3_RESUME_FAILED 0xE9 PEI_S3_RESUME_PPI_NOT_FOUND 0xEA PEI_S3_BOOT_SCRIPT_ERROR 0xEB PEI_S3_OS_WAKE_ERROR ...

Страница 43: ...front rear UID blue LED indicator will be turned on Press the UID button again to turn off the indicator 2 11 Driver Installation Guide To install the drivers to your system please insert the support CD to your optical drive first Then the drivers compatible to your system can be auto detected and listed on the support CD driver page Please follow the order from top to bottom to install those requ...

Страница 44: ...I Express module up to Gen3 x4 32Gb s Installing the M 2_SSD NGFF Module Step 1 Prepare a M 2 SSD module and the screw 2 1 3 A B C Step 2 Depending on the PCB type and length of your M 2 SSD module find the corresponding nut location to be used No 1 2 3 Nut Location NUT42 NUT80 NUT110 PCB Length 4 2cm 8cm 11cm Module Type Type2242 Type 2280 Type 22110 ...

Страница 45: ...hten the standoff into the desired nut location on the motherboard A B C A B C 20o Step 5 Align and gently insert the M 2 SSD module into the M 2 slot Please be aware that the M 2 SSD module only fits in one orientation NUT1 NUT2 C Step 6 Tighten the screw with a screwdriver to secure the module into place Please do not overtighten the screw as this might damage the module For the latest updates o...

Страница 46: ...urning the system off and then back on 3 1 1 UEFI Menu Bar The top of the screen has a menu bar with the following selections Item Description Main To set up the system time date information Advanced To set up the advanced UEFI features Server Mgmt To manage the server Security To set up the security features Boot To set up the default system device to locate and load the Operating System Event Lo...

Страница 47: ...r the selected items Tab Switch to next function Enter To bring up the selected screen PGUP Go to the previous page PGDN Go to the next page HOME Go to the top of the screen END Go to the bottom of the screen F1 To display the General Help Screen F7 Discard changes and exit the UEFI SETUP UTILITY F9 Load optimal default values for all the settings F10 Save changes and exit the UEFI SETUP UTILITY F...

Страница 48: ...3 2 Main Screen Once you enter the UEFI SETUP UTILITY the Main screen will appear and display the system overview The Main screen provides system overview information and allows you to set the system time and date ...

Страница 49: ...ns for the following items CPU Configuration Chipset Configuration Storage Configuration NVMe Configuration ACPI Configura tion USB Configuration Super IO Configuration Serial Port Console Redirection H W Monitor Network Stack Configuration RAM Disk Configuration Tls Auth Configura tion AMD PBS AMD Overclocking AMD CBS iSCSI Configuration and Instant Flash ...

Страница 50: ...3 3 1 CPU Configuration PSS Support Enable disable the generation of ACPI _PPC _PSS and _PCT objects SVM Mode Enable disable CPU Virtualization SPI LPC fTPM TPM switch To select 0 AMD CPU fTPM 1 LPC TPM 2 SPI TPM ...

Страница 51: ...e Devices this option Enables or Disables Single Root IO Virtualization Support Restore AC Power Loss Select the power state after a power failure If Power Off is selected the power will remain off when the power recovers If Power On is selected the system will start to boot up when the power recovers Restore AC Power Current State This allows you to restore AC Power Current State Onboard Debug Po...

Страница 52: ...46 English 3 3 3 Storage Configuration SATA Mode Select SATA Mode Storage Configuration of Vermeer Matisse series CPU Configure storage devices of Vermeer Matisse series CPU ...

Страница 53: ...B550D4M 47 English 3 3 4 NVMe Configuration The NVMe Configuration displays the NVMe controller and Drive information ...

Страница 54: ... PCIE Devices Power On Allow the system to be waked up by a PCIE device and enable wake on LAN RTC Alarm Power On Allow the system to be waked up by the real time clock alarm Set it to By OS to let it be handled by your operating system ...

Страница 55: ...lish 3 3 6 USB Configuration Legacy USB Support Enables Legacy USB support AUTO option disables legacy support if no USB devices are connected DISABLE option will keep USB devices available only for EFI applications ...

Страница 56: ...serial port Serial Port Address Use this item to select an optimal setting for Super IO device Set Parameters of COM2 Use this item to set parameters of Serial Port 1 COM Serial Port Use this item to enable or disable the serial port Serial Port Address Use this item to select an optimal setting for Super IO device SOL Configuration Use this item to set parameters of SOL ...

Страница 57: ...B550D4M 51 English SOL Port Use this item to enable or disable SOL Port Serial Port Address Use this item to select an optimal setting for Super IO device ...

Страница 58: ...ttings and specify how your computer and the host computer to which you are connected exchange information Both computers should have the same or compatible settings Terminal Type Use this item to select the preferred terminal emulation type for out of band management It is recommended to select VT UTF8 Option Description VT100 ASCII character set VT100 Extended VT100 that supports color and funct...

Страница 59: ... data flow Once the buffers are empty a start signal can be sent to restart the flow Hardware flow uses two wires to send start stop signals The options include None and Hardware RTS CTS VT UTF8 Combo Key Support Use this item to enable or disable the VT UTF8 Combo Key Support for ANSI VT100 terminals Recorder Mode Use this item to enable or disable Recorder Mode to capture terminal data and send ...

Страница 60: ...h a serial port Terminal Type EMS Use this item to select the preferred terminal emulation type for out of band management It is recommended to select VT UTF8 Option Description VT100 ASCII character set VT100 Extended VT100 that supports color and function keys VT UTF8 UTF8 encoding is used to map Unicode chars onto 1 or more bytes ANSI Extended ASCII character set Bits Per Second EMS Use this it...

Страница 61: ...or the status of the hardware on your system includ ing the parameters of the CPU temperature motherboard temperature CPU fan speed chassis fan speed and the critical voltage Watch Dog Timer This allows you to enable or disable the Watch Dog Timer The default value is Disabled ...

Страница 62: ...nable or disable IPv4 HTTP boot support If disabled IPv4 HTTP boot support will not be available Ipv6 PXE Support Use this item to enable or disable IPv6 PXE boot support If disabled IPv6 PXE boot support will not be available Ipv6 HTTP Support Use this item to enable or disable IPv6 HTTP boot support If disabled IPv6 HTTP boot support will not be available PXE boot wait time Wait time in seconds ...

Страница 63: ...B550D4M 57 English Media detect count Number of times the presence of media will be checked Use either or numeric keys to set the value ...

Страница 64: ...Disk Memery Type Specifies type of memory to use from available memory pool in system to create a disk Create raw Create a raw RAM disk Create from file Create a RAM disk from a given file Remove selected RAM disk s Remove selected RAM disk s ...

Страница 65: ...4M 59 English 3 3 12 Tls Auth Configuration Server CA Configuration Press Enter to configure Server CA Client Cert Configuration Enroll Cert Press Enter to enroll cert Delete Cert Press Enter to delete cert ...

Страница 66: ...s BOMAC0 MITT WITT Selection Use this item to configure MITT WITT Selection LAN Power Enable Use this item to enable or disable LAN power WLAN Enable Use this item to enable or disable WLAN Blue Tooth Enable Use this item to enable or disable Blue Tooth Wireless LAN Recovery Use this item to enable or disable Wireless LAN Recovery ...

Страница 67: ...Vddp 1 05V N 2 5 mV input rang is 0 127 Adjust V1 8 Adjust V1 8 stepping is 1mV V1 8 1 8V N 1 mV input rang is 0 127 AddCmd MemVref Adjust AddCmd MemVref Adjust stepping is VDDIO 1 256 MEM_VREF VDDIO N 256 input range is 1 255 AMD Fan Policy Air Cooling follow platform defined policy Water Cooling force PWM 100 Selecting Fan control to Manual in CBS will override this option AMD KVM Mouse Protocol...

Страница 68: ...62 English Enable wake up event occurs Power Policy Select the Power Policy mode Thunderbolt Support Enable Thunderbolt Support Zero Power ODD Enable Disable Zero Power ODD Feature ...

Страница 69: ...B550D4M 63 English 3 3 14 AMD Overclocking The AMD Overclocking menu accesses options for configuring CPU frequency and voltage ...

Страница 70: ...ons UMC Common Options Use this item to configure UMC Common options NBIO Common Options Use this item to configure NBIO Common options FCH Common Options Use this item to configure FCH Common options Chipset Common Options Use this item to configure Chipset Common options Soc Miscellaneous Control Use this item to configure Soc Miscellaneous Control ...

Страница 71: ...onfiguration Attempt Priority Change the priority using keys Use arrow keys to select the attempt then press to move the attempt up down in the attempt order list Host iSCSI Configuration Use this item to configure Host iSCSI settings ...

Страница 72: ...disk or hard drive and launch this tool then you can update your UEFI only in a few clicks without preparing an additional floppy diskette or other compli cated flash utility Please be noted that the USB flash drive or hard drive must use FAT32 16 12 file system If you execute Instant Flash utility the utility will show the UEFI files and their respective information Select the proper UEFI file to...

Страница 73: ...7 English 3 4 Server Mgmt Wait For BMC Wait For BMC response for specified time out BMC starts at the same time when BIOS starts during AC power ON It takes around 90 seconds to initialize Host to BMC interfaces ...

Страница 74: ...ng for error progress codes during boot Erase SEL Use this to choose options for earsing SEL When SEL is Full Use this to choose options for reactions to a full SEL Log EFI Status Codes Use this item to disable the logging of EFI Status Codes or log only error code or only progress code or both ...

Страница 75: ...refer using a static IP address toggle to Yes and the changes take effect after the system reboots The default value is No Configuration Address Source Select to configure BMC network parameters statically or dynamically by BIOS or BMC Configuration options Static and DHCP Static Manually enter the IP Address Subnet Mask and Gateway Address in the BIOS for BMC LAN channel configuration DHCP IP add...

Страница 76: ... the Support website at http www asrockrack com support faq asp VLAN Enabled Disabled Virtual Local Area Network If Enabled is selected configure the items below IPV6 Support Enabled Disable LAN1 IPV6 Support Manual Setting IPMI LAN IPV6 Select to configure LAN channel parameters statically or dynamically by BIOS or BMC Unspecified option will not modify any BMC network parameters during BIOS phas...

Страница 77: ...tings Use this item to Load BMC Default Settings KCS Control Select this KCS interface state after POST end If Enabled us selected the BMC will remain KCS interface after POST stage If Disabled is selected the BMC will disable KCS interface after POST stage ...

Страница 78: ...e it blank and press enter to remove the password User Password Set or change the password for the user account Users are unable to change the settings in the UEFI Setup Utility Leave it blank and press enter to remove the password Secure Boot Use this to enable or disable Secure Boot Control The default value is Disabled Enable to support Windows 8 or later versions Secure Boot Secure Boot Mode S...

Страница 79: ...nstall Default Secure Boot Keys Please install default secure boot keys if it s the first time you use secure boot Enroll Efi Image Allow the image to run in Secure Boot mode Enroll SHA256 hash of the binary into Authorized Signature Database db Restore DB Defaults Restore DB variable to factory defaults Platform Key PK Enroll Factory Defaults or load certificates from a file 1 Public Key Certific...

Страница 80: ...A2048 bin d EFI_CERT_SHAXXX 2 Authenticated UEFI Variable 3 EFI PE COFF Image SHA256 Key Source Factory External Mixed Authorized Signatures Enroll Factory Defaults or load certificates from a file 1 Public Key Certificate a EFI_SIGNATURE_LIST b EFI_CERT_X509 DER c EFI_CERT_RSA2048 bin d EFI_CERT_SHAXXX 2 Authenticated UEFI Variable 3 EFI PE COFF Image SHA256 Key Source Factory External Mixed Forb...

Страница 81: ... Public Key Certificate a EFI_SIGNATURE_LIST b EFI_CERT_X509 DER c EFI_CERT_RSA2048 bin d EFI_CERT_SHAXXX 2 Authenticated UEFI Variable 3 EFI PE COFF Image SHA256 Key Source Factory External Mixed OsRecovery Signatures Enroll Factory Defaults or load certificates from a file 1 Public Key Certificate a EFI_SIGNATURE_LIST b EFI_CERT_X509 DER c EFI_CERT_RSA2048 bin d EFI_CERT_SHAXXX 2 Authenticated U...

Страница 82: ...trols Legacy UEFI ROMs priority Fast Boot Enables Disables fast boot which skips memory training and attempts to boot using last known good configuration Boot From Onboard LAN I210 Use this item to enable or disable the Boot From Onboard LAN feature Setup Prompt Timeout Configure the number of seconds to wait for the UEFI setup utility Bootup Num Lock If this item is set to On it will automaticall...

Страница 83: ... Screen Logo Use this item to enable or disable OEM Logo The default value is Enabled AddOn ROM Display Use this option to adjust AddOn ROM Display If you enable the option Full Screen Logo but you want to see the AddOn ROM information when the system boots please select Enabled Configuration options Enabled and Disabled The default value is Enabled ...

Страница 84: ... only Select Legacy only to run those that support legacy option ROM only Select Do not launch to not execute both legacy and UEFI option ROM Launch Video OpROM Policy Select UEFI only to run those that support UEFI option ROM only Select Legacy only to run those that support legacy option ROM only Select Do not launch to not execute both legacy and UEFI option ROM PCIE4 Slot OpROM Use this item t...

Страница 85: ...s Disabled with NVMe device but it is Legacy with other devices This item can t select Video Option ROM policy MEZZ1 Slot OpROM Use this item to select slot storage and Network Option ROM policy In Auto option the default is Disabled with NVMe device but it is Legacy with other devices This item can t select Video Option ROM policy ...

Страница 86: ...ssage Discard changes and exit setup will pop out Press ESC key or select Yes to exit the UEFI SETUP UTILITY without saving any changes Discard Changes When you select this option the following message Discard changes will pop out Press F7 key or select Yes to discard all changes Load UEFI Defaults Load UEFI default values for all the setup questions F9 key can be used for this operation Boot Over...

Страница 87: ...unning The Support CD To begin using the support CD insert the CD into your CD ROM drive The CD automatically displays the Main Menu if AUTORUN is enabled in your computer If the Main Menu does not appear automatically locate and double click on the file ASRSetup exe from the root folder in the Support CD to display the menu 4 2 2 Drivers Menu The Drivers Menu shows the available device s drivers ...

Страница 88: ...fault settings 3 Check the settings of the 115V 230V switch on the power supply 4 Verify if the battery on the motherboard provides 3VDC Install a new battery if it does not If there is no video 1 Try replugging the monitor cables and power cord 2 Check for memory errors If there are memory errors 1 Verify that the DIMM modules are properly seated in the slots 2 Use recommended DDR4 ECC UDIMMs 3 I...

Страница 89: ... the battery on the motherboard provides 3VDC Install a new battery if it does not 2 Confirm whether your power supply provides adaquate and stable power Other problems 1 Try searching keywords related to your problem on ASRock Rack s FAQ page http www asrockrack com support ...

Страница 90: ...of your invoice marked with the date of purchase is required By calling your vendor or going to our RMA website http event asrockrack com tsd asp you may obtain a Returned Merchandise Authorization RMA number The RMA number should be displayed on the outside of the shipping carton which is mailed prepaid or hand carried when you return the motherboard to the manufacturer Shipping and handling char...

Отзывы: