Aspar 8I8O Скачать руководство пользователя страница 16

SDM-8I8O

User Manual

8.2.  Bit access

Modbus

Address

Dec

Address

Hex

Address

Register name

Access

Description

193

192

0x0C0 Default state of output 1 Read & Write

Default state of output  1

194

193

0x0C1 Default state of output 2 Read & Write

Default state of output  2

195

194

0x0C2 Default state of output 3 Read & Write

Default state of output  3

196

195

0x0C3 Default state of output 4 Read & Write

Default state of output  4

197

196

0x0C4 Default state of output 5 Read & Write

Default state of output  5

198

197

0x0C5 Default state of output 6 Read & Write

Default state of output  6

199

198

0x0C6 Default state of output 7 Read & Write

Default state of output  7

200

199

0x0C7 Default state of output 8 Read & Write

Default state of output  8

10801

800

0x320 Input 1

Read

Input 1 state

10802

801

0x321 Input 2

Read

Input 2 state

10803

802

0x322 Input 3

Read

Input 3 state

10804

803

0x323 Input 4

Read

Input 4 state

10805

804

0x324 Input 5

Read

Input 5 state

10806

805

0x325 Input 6

Read

Input 6 state

10807

806

0x326 Input 7

Read

Input 7 state

10808

807

0x327 Input 8

Read

Input 8 state

817

816

0x330 Output 1

Read & Write

Output 1 state

818

817

0x331 Output 2

Read & Write

Output 2 state

819

818

0x332 Output 3

Read & Write

Output 3 state

820

819

0x333 Output 4

Read & Write

Output 4 state

821

820

0x334 Output 5

Read & Write

Output 5 state

822

821

0x335 Output 6

Read & Write

Output 6 state

823

822

0x336 Output 7

Read & Write

Output 7 state

824

823

0x337 Output 8

Read & Write

Output 8 state

2113

2112

0x840 Capture 1

Read & Write

Capture counter 1

2114

2113

0x841 Capture 2

Read & Write

Capture counter 2

2115

2114

0x842 Capture 3

Read & Write

Capture counter 3

2116

2115

0x843 Capture 4

Read & Write

Capture counter 4

2117

2116

0x844 Capture 5

Read & Write

Capture counter 5

2118

2117

0x845 Capture 6

Read & Write

Capture counter 6

2119

2118

0x846 Capture 7

Read & Write

Capture counter 7

2120

2119

0x847 Capture 8

Read & Write

Capture counter 8

Expansion Module – 8 digital inputs, 8 digital outputs

User Manual

Version 1.3

16 z 18

Содержание 8I8O

Страница 1: ...SDM 8I8O Expansion Module 8 digital inputs 8 digital outputs Version 1 3 User Manual Manufactured for...

Страница 2: ...by our professionals and serve as a description of the product without incurring any liability for the purposes of commercial law This information does not release you from the obligation of own judg...

Страница 3: ...N2 and IN3 and IN4 can be used to connect two encoders All inputs and outputs are isolated from the logic of using optocouplers Each channel can be individually configured in one of several modes This...

Страница 4: ...30V Max current 500mA Output Type PNP Output protection 4A polymer fuse Isolation 1500 Vrms Counters No 8 Resolution 32 bity Frequency 1kHz max Impulse Width 500 s min Temperature Work 10 C 50 C Stor...

Страница 5: ...rectly to the rail in the DIN industry standard Power connectors communication and IOs are at the bottom and top of the module USB connector configuration and indicators located on the front of the mo...

Страница 6: ...es and their cross sections 3 2 Network Termination Transmission line effects often present a problem on data communication networks These problems include reflections and signal attenuation To elimin...

Страница 7: ...DBUS RTU or MODBUS ASCII 3 5 1 Default settings You can restore the default configuration by the switch SW8 see 3 5 2 Restore the default configuration Boud rate 19200 Pariti Nie Data bits 8 Stop bits...

Страница 8: ...00 other value 10 40005 4 0x04 Parity 0 none 1 odd 2 even 3 always 1 4 always 0 40004 3 0x03 Stop Bits LSB 1 one stop bit 2 two stop bit 40004 3 0x03 Data Bits MSB 7 7 data bits 8 8 data bits 40006 5...

Страница 9: ...ss 2 3 Module address 4 4 Module address 8 5 Module address 16 6 Module address 32 7 Module address 64 8 Restoring default settings Restoring default settings see 3 5 1 Default settings i 3 5 2 Restor...

Страница 10: ...removing To remove the panel and gain access to the switch you must pry open the panel using a thin tool eg a small screwdriver as in the picture below Expansion Module 8 digital inputs 8 digital outp...

Страница 11: ...it received the correct packet and sends the answer Inputs state LED indicates that the signal to input is connected Outputs state LED indicates that the output is on Expansion Module 8 digital inputs...

Страница 12: ...SDM 8I8O User Manual 7 Module Connection Expansion Module 8 digital inputs 8 digital outputs User Manual Version 1 3 12 z 18...

Страница 13: ...SDM 8I8O User Manual Expansion Module 8 digital inputs 8 digital outputs User Manual Version 1 3 13 z 18...

Страница 14: ...ct packets MSB Read Write 40037 36 0x24 Sent packets LSB Read Write No of sent packets 40038 37 0x25 Sent packets MSB Read Write 30051 50 0x32 Inputs Read Inputs state 40052 51 0x33 Outputs Read Write...

Страница 15: ...6 0x60 CCounter 7 LSB Read Write 32 bit value of captured counter 7 40098 97 0x61 CCounter 7 MSB Read Write 40099 98 0x62 CCounter 8 LSB Read Write 32 bit value of captured counter 8 40100 99 0x63 CCo...

Страница 16: ...ate 10805 804 0x324 Input 5 Read Input 5 state 10806 805 0x325 Input 6 Read Input 6 state 10807 806 0x326 Input 7 Read Input 7 state 10808 807 0x327 Input 8 Read Input 8 state 817 816 0x330 Output 1 R...

Страница 17: ...Read Write Captured value of counter 3 2132 2131 0x84B Captured 4 Read Write Captured value of counter 4 2133 2132 0x84C Captured 5 Read Write Captured value of counter 5 2134 2133 0x84D Captured 6 Re...

Страница 18: ...r registers of the module This program can be a convenient way to test the system as well as to observe real time changes in the registers Communication with the module is done via the USB cable The m...

Страница 19: ...odbus Registers 7 3 5 Communication settings 7 3 5 1 Default settings 7 3 5 2 Restore the default configuration 7 3 5 3 Configuration registers 8 4 Switches 9 5 Front panel removing 10 6 Indicators 11...

Отзывы: