background image

Safety Contact Mat

INSTRUCTION MANUAL

©

 ASO GmbH

All Rights Reserved

Содержание SENTIR mat

Страница 1: ...Safety Contact Mat INSTRUCTION MANUAL ASO GmbH All Rights Reserved ...

Страница 2: ...cs that is then given as a potential free relay output At the same time the entire switching circuit is wire fault or manipulation monitored In case of special requirements the SENTIR mat can be produced for a 4 wire monitoring Terminal resistance 8kOhm Mat 3 Mat 2 Mat 1 Evaluation electronic 2 2 2 2 Relay contact Voltage supply Please pay attention to Up to 10 contact mats wired in series may be ...

Страница 3: ...26 Kg m2 57 32lb 10 76ft2 approx 31 5 kg m 69 45lb 10 76ft2 Inactive edge 16 mm 0 63 30 40 mm 1 18 1 57 Switching pressure Test piece Ø 80 mm 3 15 approx 150 N Test piece Ø 80 mm 3 15 approx 150 N Static load max 2000 N over Ø 80 mm 3 15 max 2000 N over Ø 80 mm 3 15 Response time 25 ms 25 ms Switching cycles min 1 million min 1 million Electrical capacity 24 V 100 mA 24 V 100 mA Material PUR black...

Страница 4: ... 0 2 3 Number of switch zones within one mat 4 Materials ground plate U One compound mat T With molded ramp rail F For ARB or TBV cover 5 Cable versions 0 1x double lead cable connection 1 1x cable connection internal end resistor 2 2x double lead cable connection 3 1x cable connection with external resistor 4 0 1x M8 connector male and 1x M8 connector female Alternatives on request 6 Surface ARB ...

Страница 5: ...to SENTIR mat 14 ARB 14 TBV 14 NP Articel No 603020 Material PA 6 30 DV black Weight ca 29 g 0 06lb pc Aluminum surface Applicable to SENTIR mat 14 ARB Articel No 1600028 Material Aluminum 2 5 mm 0 10 max 2500 x 1400 mm 98 43 x55 12 Weight Ca 7 6 kg m 1 56 lb ft2 Steinless steel surface Applicable to SENTIR mat 14 TBV Articel No 1600016 Material Stainless steel 2 5 mm 0 10 max 2500 x 1250 mm 98 43...

Страница 6: ...nections other than those described with the instructions MOUNTING INFORMATION Preparations set up Lay out and position the mat correctly Mats may not be folded or bent Safety Contact Mats may not be manipulated in any way Cut outs or shortening is not possible The floor or mounting surface for the SENTIR mats has to be flat smooth rigid clean and dry and show no observable distortion under the he...

Страница 7: ... Safety contact mat SENTIR mat 14 with ramp rail RS 14 and mounting rail BS 14 Example of calculation 1200 mm 62 mm 62 mm 1076 mm 47 24 2 44 2 44 42 36 500 mm 62 mm 35 mm 403 mm 19 69 2 44 1 38 15 87 Ordering example SENTIR mat 14 1000 x 400 mm 19 69 2 44 with RS 14 and BS 14 also with specification for positions of RS 14 BS 14 and cable outlet resistor 8 2 kΩ Ω 400 1000 35 62 62 62 ramp rail RS 1...

Страница 8: ...d with 6 mm 0 24 dowels and appropriate screws and seal the holes with the sealing plugs fig 3 For additional ramp rails follow the same instructions The fixation rail BS 14 is used to fix SENTIR mat on the side facing the machine Mounting instructions of the ramp rail RS 14 apply to fixation rail BS 14 as well If possible cables should be led out laterally and connected to the electronic moni tori...

Страница 9: ...re ramp rails have to be cut off on the sides which are supposed to be sequenced Spray soapy water over knife and given cutting slit fig 10 Adjust the SENTIR mats and protect them against displacement fig 11 Afterwards the mats have to be connected electrically and the resistance has to be checked by a trained electrical technician experienced in safety installations The resistance is supposed not t...

Страница 10: ...unction failure as well as a risk of injury Test the SENTIR mat operations If the inspections tests performed reveal any problems do not allow use of the machine until they are rectified Record the inspection and test in a written log Thorough Examination and test Recommended twice yearly or after damage To be done by a person trained or qualified in electrical and mechanical engineering Isolate p...

Страница 11: ... safety regulations and accidents prevention rules The information contained in this operating instructions manual is provided without liability and is subject to technical modifications There are no residual risks provided that the safety instructions as well as the instructions regarding mounting commissio ning operation and maintenance are observed Exclusion of Liability The manufacturer shall ...

Страница 12: ...d for errors or misprints ENGLISH DOC0000358 Instruction Manual Rev 04 Subject to technical modifications No liability can be assumed for errors or misprints ASO Safety Solutions Inc 300 Roundhill Drive Unit 6 NJ 07866 Rockaway T 1 973 5869600 F 1 973 5861590 www asosafety com E Mail aso us asosafety com ...

Отзывы: