![ASO Safety Solutions DRICO slife 150 FU 12 Скачать руководство пользователя страница 39](http://html1.mh-extra.com/html/aso-safety-solutions/drico-slife-150-fu-12/drico-slife-150-fu-12_operating-manual_2984509039.webp)
DRICO
slife
FU 12
Operating Manual
_______________________________________________________________________________________________________________________________________
DIN EN ISO 9001
status: 31.03.2017 / Rev. 01
page 39 of 48
Display
Meaning
Start of
Event Logbook
First memory entry made
0 =>
250 ProgrammInit
Programm-Init (First entry)
…
…
HHH =>
253 RESET
Log entry due to control system restart
…
…
End of
Log-System
Last memory entry made
6.6 Parameters for reference and error numbers
The entries possible in the abovementioned log systems for events or errors that have occurred
are briefly listed below:
Reference-/
error no.
Text
Meaning
25
Stat.Edge OPEN
Stationary safety contact edge OPEN was activated
26
Stat.Edge CLOSE
Stationary safety contact edge CLOSE was activated
27
Mov.Edge OPEN
Travelling safety contact edge OPEN was activated
28
Mov.Edge CLOSE
Travelling safety contact edge CLOSE was activated
86
No.ofReversions
The maximum number of revisions for a movement
direction (without reaching the end position) was reached
130
SKL OPtstErr
Erroneous test results for the stationary safety contact
edge OPEN were detected
131
SKL CLtstErr
Erroneous test results for the stationary safety contact
edge CLOSE were detected
197
BEGIN
Program restart
201
ROM Error
The motor controller detected a program memory error
(fatal exception error)
202
EEPROM Bcc
An error occurred while accessing the EEPROM
(can sporadically occur directly while reset)
203
StackReg.Err
The motor controller detected a memory stack error
(fatal exception error)
204
StackErr:low
The motor controller detected a memory stack error
(fatal exception error)
Содержание DRICO slife 150 FU 12
Страница 1: ...drive control DRICO slife 150 270 FU 12 ...
Страница 47: ... DRICO slife 150 270 FU 12 drive control Notes ...