6.3.2 Changing the operating mode: Deadman / automatic operation
The technician can specifically switch the control system - which normally runs in automatic
operation - to deadman operation. The gate can then only be activated with the connected
deadman buttons for the OPEN and CLOSE directions (IN8 and IN7). The external safety devices
(safety contact edges and light barrier) are deactivated in the process.
-
Menu: „Service Menu“, „Password Input“: Enter password
-
Menu: „Settings“, „Operating Mode“: Select the operating mode
-
Check function!
6.3.3 STOP operating element
A STOP button or switch can be connected to input „In6“ to stop a running motor or to prevent a
motor from starting. This element must be designed as a normally closed contact. Multiple contact
circuits can also be switched sequentially one after the other in the form of a STOP chain (e.g.
motor temperature switch, access switch, STOP button).
-
Switch control system to a zero-potential state
-
Connect OPEN button to In5 and +24V input terminal (make contact)
-
Switch on power supply for control system
-
Check function!
6.3.4 OPEN operating element
In addition to the deadman OPEN, an additional OPEN button can be connected to IN5 to trigger
the opening of the gate. The function on this input is only supported in automatic operation. The
input can thus also be used by loop detectors, radio receivers, timers or static switches for
opening the gate and keeping it open.
-
Switch control system to a zero-potential state
-
Connect OPEN button to In5 and +24V input terminal (make contact)
-
Switch on power supply for control system
-
Check function!
6.3.5 Selecting the operating functions on inputs In3 and In4
Three various combinations can be selected for both command inputs In3 and In4 by selecting the
submenu „Input: In3/4“ in the „Settings“ menu. Variants 1 to 3, which are listed in the following
three tables, are available.
Variant 1
Terminal No.
Designation
Input function
3
In8
Deadman button OPEN (e.g. key switch button on gate)
4
In7
Deadman button CLOSE (e.g. key switch button on gate)
5
In6
STOP button (normally closed contact)
6
In5
OPEN impulse
7
In4
PartialOPEN impulse (pedestrian passage)
8
In3
TOGGLE switching impulse (OPEN /STOP/CLOSE /STOP / ...)
9
In2
End switch for OPEN position (normally closed contact)
10
In1
End switch for CLOSE position (normally closed contact)
Содержание DRICO slife 150 FU 12