![ASO Safety Solutions DRICO slife 150 FU 12 Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/aso-safety-solutions/drico-slife-150-fu-12/drico-slife-150-fu-12_operating-manual_2984509021.webp)
DRICO
slife
FU 12
Operating Manual
_______________________________________________________________________________________________________________________________________
DIN EN ISO 9001
status: 31.03.2017 / Rev. 01
page 21 of 48
Display
Meaning
Hold to Run Mode
Opening
Deadman operation, open gate active
Hold to Run Mode
Closing
Deadman operation, close gate active
Hold to Run Mode
Stop Immediately
Deadman operation, stop active
5.2.2 LCD sensor depiction
Detailed information on the configured sensors is also possible with the help of the display. The
current status of the configured sensors is listed by pressing the rotary and selection switch. The
individual sensors are shown sequentially by rotating the switch.
The respective sensor from the parameter list is specified in the first row.
The sensor‘s current status is displayed in the second row. Here, a „1“ represents a
n active
sensor, while a „0“ represents an inactive one. These displays are constantly updated and
facilitate easy troubleshooting. These displays are also overwritten with the depiction of the
operating modes 60 seconds after the last actuation of the rotary switch.
Sensors that are not installed (specified by parameters in the program) are also not shown.
Display
Meaning
Start of Sensors
The first entry in the sensor table is made by rotating the selection
switch to the left
LimitSwitchOPEN
Wert: 2 => x
Current value of the end switch for the gate‘s open direction
LimitSwitchCLOSE
Wert: 1 => x
Current value of the end switch for the gate‘s close direction
Stat.Edge OPEN
Wert: 1 => x
Immobile safety contact edge for the gate‘s open direction
Stat.Edge CLOSE
Wert: 1 => x
Immobile safety contact edge for the gate‘s close direction
Mov.Edge OPEN
Wert: 1 => x
Accompanying safety contact edge for the open direction (INDUS)
Mov.Edge CLOSE
Wert: 1 => x
Accompanying safety contact edge for the close direction (INDUS)
Lightbarrier
Wert: 1 => x
Status of light barrier
End of Sensors
The last entry in the sensor table is made by rotating the selection
switch to the right
5.2.3 Error / event presentation
The display proactively displays information on some error messages and special events of the
control or gate without the operator having to scroll through the diagnostics menu or the sensor
representation.
Содержание DRICO slife 150 FU 12
Страница 1: ...drive control DRICO slife 150 270 FU 12 ...
Страница 47: ... DRICO slife 150 270 FU 12 drive control Notes ...