4.3.6 Overview of input installation plan
The DRICO
slife
is configured for operation with end switches. The connection for the control
devices and sensors to the inputs is shown in a typical configuration in the following drawing:
Figure 7: Example installation with end switches, light barrier and safety contact edges
4.4 Relay output wiring
The DRICO
slife
provides three relays with normal open contact for signaling and lighting
purposes. The switching contacts are potential-free and can switch ohmic loads of maximum
250 W. The relays are preset with the following functions:
Figure no.
Terminal no.
Design.
Output function
9.1
1, 2
Rel1
Flashing light or beacon light
9.2
3, 4
Rel2
OPEN state of the gate
9.3
5, 6
Rel3
CLOSED state of the gate
The output of Rel1 (figure 4, no. 9.1) with the warning light function is permanently switched on
with the beginning of the pre-warning time and during the gate movement. The blinking function