8
230 VAC / 50 Hz Power supply connection
9
Connection for additional 230 VAC / 50 Hz loads
10 Fuse for the external 230 V loads (6,3 A) on terminal 6
3.4 Operating modes: Function and operation
The controller software is subdivided into individual function modules and is depicted for the user
in two possible operating modes (deadman operation and automatic operation).
3.4.1 Deadman operation
The gate control system can be used in deadman (Hold To Run) operation with limited comfort. In
deadman operation the gate can only be moved with the OPEN and CLOSE buttons specifically
connected to inputs ,In8‘ and ,In7‘. The gate does not require any safety contact strips for this
operation. The gate is only in operation for as long as the open or close button is pressed.
Deadman operation is only permitted, if the user has full visual contact with the gate system.
Even in deadman operation mode a STOP button is to be provided for in addition to the OPEN
and CLOSE buttons. If this button is not to be connected, the relevant input must be connected by
a wire bridge with +24 volts.
The control system also automatically switches out of automatic operation to this operating mode
if the safety devices on the gate do no longer permit automatic operation (e.g. defective safety
edges / light barrier). In this case the operator must also keep the command button (OPEN [In8] or
CLOSE [In7]) continuously pressed. The gate movement will only be initiated with a delay of 2
seconds. This is a safety feature and serves to signal the operator the transition from automatic
mode to deadman operating mode.
3.4.2 Automatic operation
The control system is normally operated in this automatic mode when safety is completely
established. All
of the control system‘s functions are only available to the user in automatic
operation. Here, the gate‘s complete safety is guaranteed b
y the activated safety devices.
In automatic operation a gate movement can be initiated by:
deadman button OPEN or CLOSE
Control device (OPEN or PartialOPEN)
Impulse button with TOGGLE function (OPEN, STOP, CLOSE, STOP)
Commands via radio remote control
Every command results in the execution of the complete, selected action (open gate, close gate,
etc.). Every action is immediately ended with a stop command or a signal from the safety devices.
Activation of the safety contact edges results in an immediate, complete reversal of the gate. An
interruption of the light barrier during the closing operation also results in the gate opening.
A movement command for the opposite direction of the current movement gently brakes the gate