background image

Installation instructions

Gas hobs 

05

 

A (mm) 

B (mm) 

C (mm)  D (mm)  E (>mm)  F (>mm)  G 

H

HG11 

600 

1070 

380 

60 30 50 55 100

HG13 

600 

290 

490 

60 30 50 55 100

HG16 

600 

560 

490 

60 30 50 50 100

HG18 

600 

750 

490 

60 30 50 50 100

HG19 

600 

860 

490 

60 30 50 50 100

E

E/F

C

D

G

B

A

F

H

 

A (mm)  B (mm)  C (mm)  D (mm) 

HG11 

min. 650  min. 900  min. 450  min. 120 

HG13 

min. 650  min. 600  min. 450  min. 120

HG16 

min. 650  min. 600  min. 450  min. 120 

HG18 

min. 650  min. 750  min. 450  min. 120 

HG19 

min. 650  min. 900  min. 450  min. 120 

A

B

C

D

A

B

C

E

D

 

A (mm)  B (mm)  C (mm)  D (mm)  E (mm)

HG11 

1114 

412 

48 48 387 

HG13 330 

522 

48 

48 

75

HG16 644 

522 

45 

45 

69 

HG18 794 

522 

45 

31 

440 

HG19 904 

522 

45 

45 

517 

The gas connection must comply with national and local regulations.

The hotplate can be connected with rigid pipe as specified in 
AS/NZS 5601.1current edition.

When the appliance is connected with a hose assembly, 
the supply point shall be accessible with the appliance installed.

 

 

 

240 V - 50 Hz - max. 20 W  

This appliance must be earthed

 

The electrical connection must comply with national and local regulations.

 

 

 

1/2” ISO 228 / 1/2" ISO 7-1  

Free space around appliance

The fitting of the appliance should only be carried out by a authorised person/licensed gasfitter. Please read the safety regulations.
See the data plate for information regarding the total gas consumption, gas type and gas pressure.

Rangehoods and exhaust fans shall be 
installed in accordance with
manufacturers instructions.

For an overhead exhaust fan A>750 mm!

Gas connection

Important information

Pictograms used

Electrical  connection

y

y

x

x

>60º C

<60º C

oven

oven

Accessibility!

Y: 

metal
Gas supply valve 
shall be accessible

X: 

safety hose
Gas supply valve 
shall be accessible

 

 

   

   
   

 

Preparations for installation

Отзывы: