Installation instructions
Gas hobs
05
A (mm)
B (mm)
C (mm) D (mm) E (>mm) F (>mm) G
H
HG11
600
1070
380
60 30 50 55 100
HG13
600
290
490
60 30 50 55 100
HG16
600
560
490
60 30 50 50 100
HG18
600
750
490
60 30 50 50 100
HG19
600
860
490
60 30 50 50 100
E
E/F
C
D
G
B
A
F
H
A (mm) B (mm) C (mm) D (mm)
HG11
min. 650 min. 900 min. 450 min. 120
HG13
min. 650 min. 600 min. 450 min. 120
HG16
min. 650 min. 600 min. 450 min. 120
HG18
min. 650 min. 750 min. 450 min. 120
HG19
min. 650 min. 900 min. 450 min. 120
A
B
C
D
A
B
C
E
D
A (mm) B (mm) C (mm) D (mm) E (mm)
HG11
1114
412
48 48 387
HG13 330
522
48
48
75
HG16 644
522
45
45
69
HG18 794
522
45
31
440
HG19 904
522
45
45
517
The gas connection must comply with national and local regulations.
The hotplate can be connected with rigid pipe as specified in
AS/NZS 5601.1current edition.
When the appliance is connected with a hose assembly,
the supply point shall be accessible with the appliance installed.
240 V - 50 Hz - max. 20 W
This appliance must be earthed
The electrical connection must comply with national and local regulations.
1/2” ISO 228 / 1/2" ISO 7-1
Free space around appliance
The fitting of the appliance should only be carried out by a authorised person/licensed gasfitter. Please read the safety regulations.
See the data plate for information regarding the total gas consumption, gas type and gas pressure.
Rangehoods and exhaust fans shall be
installed in accordance with
manufacturers instructions.
For an overhead exhaust fan A>750 mm!
Gas connection
Important information
Pictograms used
Electrical connection
y
y
x
x
>60º C
<60º C
oven
oven
Accessibility!
Y:
metal
Gas supply valve
shall be accessible
X:
safety hose
Gas supply valve
shall be accessible
Preparations for installation