Preparation for Work - 1
Mains Cable Connection / Controls and Operational Characteristics :
Check the mains voltage, phases and frequency before operating the machine. The mains voltage to
be used is declared in the section “Technical Characteristics” of this manual and on the name-plate
of the machine.
Make sure that the cables connecting the machine to the mains are properly grounded and power
supply is sufficient for the normal operation of the machine. The welding machine must only
connected to a 16 A slow-blow fuse protected line with the plug provided.
1- This machine has been designed to operate on 1 phase, 220 V (AC) and 50-60 Hz mains
voltage with insulation based on the line-neutral voltage values. It should be used only with
the single phase, 3 wire systems with earthed neutral.
2- The machine must not be connected to the mains and turned on without a proper protective
grounding approved by an authorized electrician. The electrical leaks may be fatal for the
human health.
3- Do not connect
to a 3-phase mains system. Any damages caused to the machine by incorrect
connection to the mains are not covered by the warranty.