Using the Web Server
– After all your messages have been defined, don’t forget
to click on
Configure
to save all the message
definitions.
•
Click on the
Raw Data Messages
submenu. Use the page
that opens to program the type of raw data you would like
the receiver to record.
Manual raw data will later be initiated either remotely by
enabling the
Data Recording
box on the
Recording
web
page, or locally using the
Log
button on the receiver front
panel.
For example, to set the RNX and NAV raw data messages
at 1 second, do the following:
– In the
ATOM Messages
pane, select “RNX” from the
Message
field, select “M” or “U” from the
Output
field
and type “1” in the
Rate
field. Click on the
Add
button
underneath to validate your entry. The programmed
message now appears in the table on the right.
– In the
ATOM Messages
pane, select “NAV” from the
Message
field, select “M” or “U” from the
Output
field
and type “1” in the
Rate
field. Click on the
Add
button
underneath to validate your entry. The programmed
message now appears in the table on the right.
– Click on the
Configure
button located at the bottom of
the page
•
Click on the
Connections
menu, then on the
Serial Ports
submenu.
•
Set each of the ports on which data output will take place.
If port B or F is used, make sure the Power ON option
(bottom of the page) is active.
Setting a Base
How to Start
•
Open the Web Server’s
Configuration
tab. The first time you
click on this tab, the Web Server will ask you to log in as
the administrator. Only the receiver administrator is
authorized to access the
Configuration
tab.
You are allowed to change the destination of a receiver
(e.g. it is currently a rover and you want to change it into
a base). In this case, on opening the
Base Setup
tab, the
Web Server will retain part of the rover settings that could
be applied to the base (e.g. antenna type, etc.).
Содержание HDS800
Страница 1: ...Reference Manual HDS800...
Страница 16: ...x Enabling a Firmware Option 639 Decoding an NTRIP Source Table 639 Logging Raw Data 642...
Страница 54: ...38 Receiver Description...
Страница 104: ...88 Using the Web Server...
Страница 161: ...145 Web Server Help Files Collection Configuration Tab These groups of parameters are detailed below...
Страница 189: ...173 Web Server Help Files Collection Configuration Tab...
Страница 250: ...234 Ethernet Connection dd is the day number 1 31 when the file was created The file extension is log...
Страница 266: ...250 Using Serial Commands...
Страница 606: ...590 Query Command Library...
Страница 619: ...603 Data Output...
Страница 628: ...612 Data Output...
Страница 650: ...634 Troubleshooting...
Страница 660: ...644 Other Procedures Memos...
Страница 676: ...X XDR 110 112 587 Z Z Blade 1 ZDA 347 431 588...
Страница 677: ......