Operating Manual - nX, nXe, and nXp Power Amplifiers
11 ASHLY REMOTE CONTROL DEVICES
In addition to iPad control, the following Ashly devices are available for remote control of amplifier functions.
11.1 WR-1 Level Control (All nX models)
- The WR-1 is a dual potentiometer remote volume control de
-
signed to fit in a standard wall electrical box, and is wired to the amplifier back panel Euroblock connector labeled “CH
(1-4) Remote DC Level” using four conductor wire. If wiring a custom potentiometer other than the WR-1, connect
+5V from the remote level control Euroblock connector to the potentiometer's CW pin, GND to the CCW pin, and the
channel under control to the wiper.
Do not connect the WR-1 remote level control ground to any other external grounds.
11.1 - WR-1 Assembly
11.1a - WR-1 Wiring
11.2 WR-1.5 Level Control and Preset Recall Switch
(Level
Control all models, preset recall on nXe and nXp models only)
- The
WR-1.5 has a four position rotary switch for selection of stored amplifier
presets 1-4, and a potentiometer for remote DC level control of one amplifier
channel. Clear windows are provided for user generated labels.
11.2 - WR-1.5
11.3 WR-2 Preset Recall Switches
(nXe and nXp only)
- The WR-2
allows selection of stored amplifier presets 1-4 using pushbutton switches.
Each pushbutton switch is connected to a preset recall pin on the back panel
of the amplifier under control. The terminal numbers correspond to the first
4 preset memory locations in the controlled amplifier. Pressing a button
will select and load the corresponding amplifier preset. Clear windows are
provided for a user-generated label.
11.3 - WR-2