13
Operating Manual - nX, nXe, and nXp Power Amplifiers
6 nXe SERIES REAR PANEL FEATURES
The following nXe features are in addition to standard features found in nX series amplifiers:
6.1 Ethernet Port
- This RJ-45 connector offers Ethernet control and monitoring of the amplifier using Protea
ne
software.
in this manual for details on Ethernet communications.
6.2 Network Audio
-
This is for an optional factory installed CobraNet or Dante
network audio module
for details.
6.3 Standby Contact Closure
-
The STBY pin, when connected to the ground pin (G) as shown,
will remotely place the amp into standby mode. When the connection is opened, the amplifier returns to
normal operation. The front panel power switch will flash when the amplifier is in standby.
6.4 Fault Pins
- A fault logic output pin is available for each amplifier
output channel. Fault pins are used to drive external LEDs or connect
with equipment that can remotely monitor or respond to a serious ampli
-
fier problem. A fault is indicated by the loss of a normally present "heartbeat" signal, where the
output continuously toggles between 0V and +5V at a 1Hz rate.
The normal heartbeat signal on each fault pin is interrupted
whenever a fault condition prevents normal function of that
channel while the amplifier is either powered on or in the
standby state. Fault conditions include loss of AC mains
voltage, excessive internal temperature, power supply
voltage out of range, DC on output, or microprocessor
malfunction. A fault pin output can directly drive an LED
as shown in the circuit illustration to the right.
If a fault occurs, fault pin output may be latched <Low> or
<High> depending on the type of fault or state of the output
at the moment the fault occurred. A fail-safe fault detection
circuit should monitor and respond only to the loss of the
1Hz heartbeat signal.
6.5 Preset
-
Each pin (P1 through P4) can be connected to the adjacent ground pin (G) via Ashly's WR-2 remote or other contact closure
to recall a stored preset or sub preset from the amplifier. Preset pins 1-4 correspond directly to amplifier presets 01 - 04.
6.6 Serial Data Connector
-
These four pins (G, +18, OUT, IN) are for connecting a serial data remote control such as an Ashly
WR-5 or RD-8C. Ashly also offers an in-line converter called the
which allows the data port to be used with third party RS-232 con
-
trollers. A technical
is available on the Ashly website for third party developers. See more data remote control
application details in
6.7 AUX Outputs
-
These Euroblock connectors provide preamp signals for driving other amplifiers. See the
on page 59 for the differences between two and four channel amplifier AUX outputs. AUX outputs are pseudo-balanced, meaning
they use single ended signal with balanced impedance, and can be wire balanced or unbalanced.
6.8 AES3 Digital Audio I/O Option
-
This is used for Ashly's two or four channel AES3 input and pass-through module,
available as a factory installed option on nXe and nXp models. See
for AES3 details.
6.3 Standby Circuit